Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

M. J. Sibilia

dblp:191/1256 · DBLP profile ↗
← Back
1ranked-venue papers
0as first author
0since 2021 · last 1984
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 1Systems, architecture and hardware · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
1 paper
Robot navigation and mapping · 77% Robot manipulation · 23%

Topics — the 2 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot navigation and mapping › acoustic sensing
ultrasonic range sensing
0.011984
Active damping of ultrasonic transducers for robotic applications · ICRA 1984
Robotics › Robot manipulation › grasping › robotic gripper
gripper sensing
0.011984
Active damping of ultrasonic transducers for robotic applications · ICRA 1984

Methods — techniques the papers use, named apart from their topics

active damping · 0.0LC resonant circuit · 0.0
YearPublicationVenuePosition
1984 Active damping of ultrasonic transducers for robotic applications
abstract
Ultrasonic ranging in air over short distances offers advantages for robotic applications. Such sensing methods can employ transducers small enough to fit into a robot gripper, thereby providing terminal homing capability. Any such short range time-of-flight systems, however, have to solve the problem of rapid receiver recovery after the transmit pulse. In the present case the problem has been solved by an active damping scheme. The transducer is a capacitive element and is connected across an inductor to form an electrically resonant circuit at the acoustic frequency of interest. The LC tank is in the feedback path of a novel circuit that can be changed continuously from positive to negative feedback conditions. When the feedback is positive oscillations rapidly build up, when negative they just as rapidly die down. At the end of each positive - negative cycle essentially all of both the electrical and mechanical energy has been extracted from the system, which is then ready to receive the echo. In this way ranging is readily achieved down to ∼1", which is adequate for robot gripper applications.
Gerald L. Miller, Robert A. Boie, M. J. Sibilia
ICRA3