Demo Data from SIGIR 2026 / reviewers in the wild / expert
Virginia Mamone
dblp:201/0507
· DBLP profile ↗
2ranked-venue papers
1as first author
2since 2021 · last 2023
0000-0002-7172-5119ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Human-computer interaction and ubiquitous computing · 1 · 1 first-author · 1 since 2021Applied, interdisciplinary, general and emerging computing · 1 · 1 since 2021
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
1 paper |
Robot manipulation · 56% Motion planning and robot control · 44% |
Topics — the 5 heaviest of 5, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Robot manipulation › medical robotics › surgical robotics
minimally invasive surgery |
0.7 | 1 | 2023 | Semiautonomous Robotic Manipulator for Minimally Invasive Aortic Valve Replacement · IEEE Trans. Robotics 2023 |
Robotics › Motion planning and robot control
robot control |
0.7 | 1 | 2023 | Semiautonomous Robotic Manipulator for Minimally Invasive Aortic Valve Replacement · IEEE Trans. Robotics 2023 |
Robotics › Robot manipulation › medical robotics
surgical robotics |
0.7 | 1 | 2023 | Semiautonomous Robotic Manipulator for Minimally Invasive Aortic Valve Replacement · IEEE Trans. Robotics 2023 |
Robotics › Motion planning and robot control › teleoperation
haptic teleoperation |
0.2 | 1 | 2023 | Semiautonomous Robotic Manipulator for Minimally Invasive Aortic Valve Replacement · IEEE Trans. Robotics 2023 |
Robotics › Motion planning and robot control
teleoperation |
0.2 | 1 | 2023 | Semiautonomous Robotic Manipulator for Minimally Invasive Aortic Valve Replacement · IEEE Trans. Robotics 2023 |
Methods — techniques the papers use, named apart from their topics
visual servoing · 0.7hybrid forward/inverse mechanics · 0.7force observer · 0.7
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2023 | Semiautonomous Robotic Manipulator for Minimally Invasive Aortic Valve ReplacementabstractAortic valve surgery is the preferred procedure for replacing a damaged valve with an artificial one. The ValveTech robotic platform comprises a flexible articulated manipulator and surgical interface supporting the effective delivery of an artificial valve by teleoperation and endoscopic vision. This article presents our recent work on force-perceptive, safe, semiautonomous navigation of the ValveTech platform prior to valve implantation. First, we present a force observer that transfers forces from the manipulator body and tip to a haptic interface. Second, we demonstrate how hybrid forward/inverse mechanics, together with endoscopic visual servoing, lead to autonomous valve positioning. Benchtop experiments and an artificial phantom quantify the performance of the developed robot controller and navigator. Valves can be autonomously delivered with a 2.0±0.5 mm position error and a minimal misalignment of 3.4±0.9°. The hybrid force/shape observer (FSO) algorithm was able to predict distributed external forces on the articulated manipulator body with an average error of 0.09 N. FSO can also estimate loads on the tip with an average accuracy of 3.3%. The presented system can lead to better patient care, delivery outcome, and surgeon comfort during aortic valve surgery, without requiring sensorization of the robot tip, and therefore obviating miniaturization constraints. Izadyar Tamadon, S. M. Hadi Sadati, Virginia Mamone, Vincenzo Ferrari, Christos Bergeles, Arianna Menciassi |
IEEE Trans. Robotics | 3 |
| 2022 | Projected Augmented Reality to Guide Manual Precision Tasks: An Alternative to Head Mounted DisplaysabstractAugmented reality (AR) devices are gaining popularity in industrial development and healthcare as they provide information that would not be accessible in a rapid and intuitive way. Head-mounted displays dominate in this field and are currently being comprehensively tested. Alongside its informative function, AR can be used to steer the user's actions to aid complex or high precision tasks. This is the case in surgery, which is recently seeing the development of ad-hoc head-mounted displays to meet the requirements of safety, ergonomics, and reliability. However, head-mounted displays are subject to perceptual problems that can affect their use in delicate and demanding tasks. This article aims to evaluate projected AR as an alternative to head mounted displays (HMDs) when accurate guidance on the surface is needed. We directly compare them in a user study and evaluate both user accuracy and user perception to assess whether projected AR can be a practical and useful paradigm for precision manual tasks. Ten users performed tracing trajectory tasks under the guidance of an HMD and a projected AR device. Three accuracy levels were quantitatively tested: 0.5, 1, and 2 mm. Statistical analysis showed no significant difference in the accuracy of the two AR visualization modes, whereas the user perception assessment revealed statistical differences in virtual-to-real perception and visual discomfort. The quantitative results of this article proved that both technologies can guide manual precision tasks with the same accuracy, but projected AR features some perceptual advantages. Virginia Mamone, Fabrizio Cutolo, Sara Condino, Vincenzo Ferrari |
IEEE Trans. Hum. Mach. Syst. | 1 |