Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Fabio Carrillo

dblp:205/3523 · DBLP profile ↗
← Back
6ranked-venue papers
2as first author
4since 2021 · last 2025
0000-0002-0942-0277ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 4 · 2 first-author · 2 since 2021Artificial intelligence and machine learning · 2 · 2 since 2021Graphics, computer vision, multimedia, augmented reality and games · 1 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
1 paper
Motion planning and robot control · 75% Robot manipulation · 25%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 6 heaviest of 6, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Motion planning and robot control › robot learning › robotic reinforcement learning
reinforcement learning for robot control
0.912025
SonoGym: High Performance Simulation for Challenging Surgical Tasks with Robotic Ultrasound · NeurIPS 2025
Robotics › Motion planning and robot control
robot control
0.912025
SonoGym: High Performance Simulation for Challenging Surgical Tasks with Robotic Ultrasound · NeurIPS 2025
Robotics › Robot manipulation › medical robotics
robotic ultrasound
0.912025
SonoGym: High Performance Simulation for Challenging Surgical Tasks with Robotic Ultrasound · NeurIPS 2025
Robotics › Motion planning and robot control
robot learning
0.912025
SonoGym: High Performance Simulation for Challenging Surgical Tasks with Robotic Ultrasound · NeurIPS 2025
Medical and health informatics
computer-assisted surgery
0.312025
SonoGym: High Performance Simulation for Challenging Surgical Tasks with Robotic Ultrasound · NeurIPS 2025
Medical and health informatics
surgical robotics
0.312025
SonoGym: High Performance Simulation for Challenging Surgical Tasks with Robotic Ultrasound · NeurIPS 2025

Methods — techniques the papers use, named apart from their topics

vision transformer · 1.7submodular reinforcement learning · 1.7safe reinforcement learning · 1.7imitation learning · 1.7generative adversarial network · 1.7diffusion policy · 1.7deep reinforcement learning · 1.7
YearPublicationVenuePosition
2025 SonoGym: High Performance Simulation for Challenging Surgical Tasks with Robotic Ultrasound
abstract
Ultrasound (US) is a widely used medical imaging modality due to its real-time capabilities, non-invasive nature, and cost-effectiveness. By reducing operator dependency and enhancing access to complex anatomical regions, robotic ultrasound can help improve workflow efficiency. Recent studies have demonstrated the potential of deep reinforcement learning (DRL) and imitation learning (IL) to enable more autonomous and intelligent robotic ultrasound navigation. However, the application of learning-based robotic ultrasound to computer-assisted surgical tasks, such as anatomy reconstruction and surgical guidance, remains largely unexplored. A key bottleneck for this is the lack of realistic and efficient simulation environments tailored to these tasks. In this work, we present SonoGym, a scalable simulation platform for robotic ultrasound, enabling parallel simulation across tens to hundreds of environments. Our framework supports realistic and real-time simulation of US data from CT-derived 3D models of the anatomy through both a physics-based and a Generative Adversarial Network (GAN) approach. Our framework enables the training of DRL and recent IL agents (vision transformers and diffusion policies) for relevant tasks in robotic orthopedic surgery by integrating common robotic platforms and orthopedic end effectors. We further incorporate submodular DRL---a recent method that handles history-dependent rewards---for anatomy reconstruction and safe reinforcement learning for surgery. Our results demonstrate successful policy learning across a range of scenarios, while also highlighting the limitations of current methods in clinically relevant environments. We believe our simulation can facilitate research in robot learning approaches for such challenging robotic surgery applications. Dataset, codes and videos are publicly available at https://sonogym.github.io/.
Yunke Ao, Masoud Moghani, Mayank Mittal, Manish Prajapat, Luohong Wu, Frédéric H. Giraud, Fabio Carrillo, Andreas Krause 0001, Philipp Fürnstahl
NeurIPS7
2025 SafeRPlan: Safe deep reinforcement learning for intraoperative planning of pedicle screw placement
abstract
Spinal fusion surgery requires highly accurate implantation of pedicle screw implants, which must be conducted in critical proximity to vital structures with a limited view of the anatomy. Robotic surgery systems have been proposed to improve placement accuracy. Despite remarkable advances, current robotic systems still lack advanced mechanisms for continuous updating of surgical plans during procedures, which hinders attaining higher levels of robotic autonomy. These systems adhere to conventional rigid registration concepts, relying on the alignment of preoperative planning to the intraoperative anatomy. In this paper, we propose a safe deep reinforcement learning (DRL) planning approach (SafeRPlan) for robotic spine surgery that leverages intraoperative observation for continuous path planning of pedicle screw placement. The main contributions of our method are (1) the capability to ensure safe actions by introducing an uncertainty-aware distance-based safety filter; (2) the ability to compensate for incomplete intraoperative anatomical information, by encoding a-priori knowledge of anatomical structures with neural networks pre-trained on pre-operative images; and (3) the capability to generalize over unseen observation noise thanks to the novel domain randomization techniques. Planning quality was assessed by quantitative comparison with the baseline approaches, gold standard (GS) and qualitative evaluation by expert surgeons. In experiments with human model datasets, our approach was capable of achieving over 5% higher safety rates compared to baseline approaches, even under realistic observation noise. To the best of our knowledge, SafeRPlan is the first safety-aware DRL planning approach specifically designed for robotic spine surgery.
Yunke Ao, Hooman Esfandiari, Fabio Carrillo, Christoph J. Laux, Yarden As, Ruixuan Li 0003, Kaat Van Assche, Ayoob Davoodi, Nicola Cavalcanti, Mazda Farshad, Benjamin F. Grewe, Emmanuel B. Vander Poorten, Andreas Krause 0001, Philipp Fürnstahl
Medical Image Anal.3
2025 Next-generation surgical navigation: Marker-less multi-view 6DoF pose estimation of surgical instruments
abstract
State-of-the-art research of traditional computer vision is increasingly leveraged in the surgical domain. A particular focus in computer-assisted surgery is to replace marker-based tracking systems for instrument localization with pure image-based 6DoF pose estimation using deep-learning methods. However, state-of-the-art single-view pose estimation methods do not yet meet the accuracy required for surgical navigation. In this context, we investigate the benefits of multi-view setups for highly accurate and occlusion-robust 6DoF pose estimation of surgical instruments and derive recommendations for an ideal camera system that addresses the challenges in the operating room. Our contributions are threefold. First, we present a multi-view RGB-D video dataset of ex-vivo spine surgeries, captured with static and head-mounted cameras and including rich annotations for surgeon, instruments, and patient anatomy. Second, we perform an extensive evaluation of three state-of-the-art single-view and multi-view pose estimation methods, analyzing the impact of camera quantities and positioning, limited real-world data, and static, hybrid, or fully mobile camera setups on the pose accuracy, occlusion robustness, and generalizability. Third, we design a multi-camera system for marker-less surgical instrument tracking, achieving an average position error of 1.01mm and orientation error of 0.89° for a surgical drill, and 2.79mm and 3.33° for a screwdriver under optimal conditions. Our results demonstrate that marker-less tracking of surgical instruments is becoming a feasible alternative to existing marker-based systems.
Jonas Hein, Nicola Cavalcanti, Daniel Suter, Lukas Zingg, Fabio Carrillo, Lilian Calvet, Mazda Farshad, Nassir Navab, Marc Pollefeys, Philipp Fürnstahl
Medical Image Anal.5
2023 Automatic breach detection during spine pedicle drilling based on vibroacoustic sensing
abstract
Pedicle drilling is a complex and critical spinal surgery task. Detecting breach or penetration of the surgical tool to the cortical wall during pilot-hole drilling is essential to avoid damage to vital anatomical structures adjacent to the pedicle, such as the spinal cord, blood vessels, and nerves. Currently, the guidance of pedicle drilling is done using image-guided methods that are radiation intensive and limited to the preoperative information. This work proposes a new radiation-free breach detection algorithm leveraging a non-visual sensor setup in combination with deep learning approach. Multiple vibroacoustic sensors, such as a contact microphone, a free-field microphone, a tri-axial accelerometer, a uni-axial accelerometer, and an optical tracking system were integrated into the setup. Data were collected on four cadaveric human spines, ranging from L5 to T10. An experienced spine surgeon drilled the pedicles relying on optical navigation. A new automatic labeling method based on the tracking data was introduced. Labeled data was subsequently fed to the network in mel-spectrograms, classifying the data into breach and non-breach. Different sensor types, sensor positioning, and their combinations were evaluated. The best results in breach recall for individual sensors could be achieved using contact microphones attached to the dorsal skin (85.8%) and uni-axial accelerometers clamped to the spinous process of the drilled vertebra (81.0%). The best-performing data fusion model combined the latter two sensors with a breach recall of 98%. The proposed method shows the great potential of non-visual sensor fusion for avoiding screw misplacement and accidental bone breaches during pedicle drilling and could be extended to further surgical applications.
Aidana Massalimova, Maikel Timmermans, Nicola Cavalcanti, Daniel Suter, Matthias Seibold, Fabio Carrillo, Christoph J. Laux, Reto Sutter, Mazda Farshad, Kathleen Denis, Philipp Fürnstahl
Artif. Intell. Medicine6
2020 An automatic genetic algorithm framework for the optimization of three-dimensional surgical plans of forearm corrective osteotomies
Fabio Carrillo, Simon Roner, Marco von Atzigen, Andreas Schweizer, Ladislav Nagy, Lazaros Vlachopoulos, Jess Gerrit Snedeker, Philipp Fürnstahl
Medical Image Anal.1
2017 A Time Saver: Optimization Approach for the Fully Automatic 3D Planning of Forearm Osteotomies
Fabio Carrillo, Lazaros Vlachopoulos, Andreas Schweizer, Ladislav Nagy, Jess Gerrit Snedeker, Philipp Fürnstahl
MICCAI (2)1