Demo Data from SIGIR 2026 / reviewers in the wild / expert
Roman Heimgartner
dblp:226/6144
· DBLP profile ↗
2ranked-venue papers
0as first author
0since 2021 · last 2019
0000-0002-2099-348XORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 2Systems, architecture and hardware · 2
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Human-computer interaction and pervasive computing
2 papers |
Accessibility and assistive technology · 37% Human-robot interaction · 34% Health and well-being technologies · 29% |
Topics — the 4 heaviest of 5, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Accessibility and assistive technology
assistive technology |
0.4 | 1 | 2019 | Soft Robotic Glove with Integrated Sensing for Intuitive Grasping Assistance Post Spinal Cord Injury · ICRA 2019 |
Health and well-being technologies › rehabilitation technology
soft robotic glove |
0.4 | 1 | 2019 | Soft Robotic Glove with Integrated Sensing for Intuitive Grasping Assistance Post Spinal Cord Injury · ICRA 2019 |
Human-robot interaction › wearable robot
soft exosuit |
0.3 | 1 | 2018 | Autonomous and Portable Soft Exosuit for Hip Extension Assistance with Online Walking and Running Detection Algorithm · ICRA 2018 |
Accessibility and assistive technology › locomotion assistance
gait assistance |
0.1 | 1 | 2018 | Autonomous and Portable Soft Exosuit for Hip Extension Assistance with Online Walking and Running Detection Algorithm · ICRA 2018 |
Methods — techniques the papers use, named apart from their topics
state machine intent detection · 0.4capacitive sensing · 0.4human-in-the-loop optimization · 0.3IMU-based activity classification · 0.3
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2019 | Soft Robotic Glove with Integrated Sensing for Intuitive Grasping Assistance Post Spinal Cord InjuryabstractThis paper presents a fully-integrated soft robotic glove with multi-articular textile actuators, custom soft sensors, and an intuitive state machine intent detection controller. We demonstrate that the pressurized actuators can generate motion and force comparable to natural human fingers through bench-top testing. We apply textile-elastomer capacitive sensors to the glove to track finger flexion via strain and detect contact with objects via force. Intuitive user control is achieved via a state machine controller based on signals from the integrated sensors to detect relative changes in hand-object interactions. Results from an initial evaluation with 3 participants with spinal cord injury (SCI), of varied injury levels and years since injury, wearing and controlling the glove show an average of 87% improvement in grasping force, and improvements in functional assessments for participants with recent injuries. A significant variation in response suggests further investigation is required to understand the adaptation needed across different injury levels and durations since injury. Additionally, we evaluate the controller and find an average of 3 seconds from user initiations to completed grasps, and 10% inadvertent grasp triggers and no false releases when objects are held. Yu Meng Zhou, Diana Wagner, Kristin Nuckols, Roman Heimgartner, Carolina Correia, Megan E. Clarke, Dorothy Orzel, Ciarán T. O'Neill, Ryan Solinsky, Sabrina Paganoni, Conor J. Walsh |
ICRA | 4 |
| 2018 | Autonomous and Portable Soft Exosuit for Hip Extension Assistance with Online Walking and Running Detection AlgorithmabstractWe present an autonomous and portable hip-only soft exosuit, for augmenting human walking and running that assists hip extension by delivering peak forces of 300N to the user. Different fixed assistance profiles for walking and running were applied based on an online classification algorithm. The approach is based on the biomechanical understanding that the center of mass potential energy fluctuations during walking and running are out of phase. Specifically, we monitor the vertical acceleration with an abdomen-mounted IMU at the moment of maximum hip extension. Validation is demonstrated with six subjects on the treadmill and with eight subjects outdoors. Our results demonstrated a 99.99% accuracy on average over the fourteen participants for various speeds (0.5 - 4m/s), slopes (-10 -20%), treadmill and overground terrain, loaded (13.6 kg) and unloaded, Exo On and Exo Off conditions, and different shoe types. Results from an evaluation outdoors overground on the energetics of eight subjects demonstrated a significant reduction for running when comparing Exo On to No Exo (3.9%) and for walking and running when comparing Exo On to Exo Off (12.2% and 8.2% respectively). This study represents the first demonstration of an autonomous wearable robot reducing the energy cost of running. Significant variation in response across subjects was observed, highlighting further improvements may be possible via assistance profile individualization with human-in-the-Ioop optimization. Jinsoo Kim 0006, Roman Heimgartner, Giuk Lee, Nikos Karavas, David Perry, Danielle Louise Ryan, Asa M. Eckert-Erdheim, Dabin Kim Choe, Ignacio Galiana, Conor J. Walsh |
ICRA | 2 |