Demo Data from SIGIR 2026 / reviewers in the wild / expert
Laurent Schoevaerdts
dblp:226/6374
· DBLP profile ↗
2ranked-venue papers
1as first author
0since 2021 · last 2018
0000-0003-1481-3005ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 2 · 1 first-authorSystems, architecture and hardware · 2 · 1 first-author
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
2 papers |
Motion planning and robot control · 77% Robot manipulation · 23% | |
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% |
Topics — the 3 heaviest of 4, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Motion planning and robot control
computer assisted surgery |
0.3 | 1 | 2018 | Innovative Bio-Impedance Sensor Towards Puncture Detection in Eye Surgery for Retinal Vein Occlusion Treatment · ICRA 2018 |
Robotics › Motion planning and robot control
robot control |
0.3 | 1 | 2018 | Innovative Bio-Impedance Sensor Towards Puncture Detection in Eye Surgery for Retinal Vein Occlusion Treatment · ICRA 2018 |
Medical and health informatics › surgical robotics
robot-assisted surgery |
0.3 | 1 | 2018 | Development and Experimental Validation of a Combined FBG Force and OCT Distance Sensing Needle for Robot-Assisted Retinal Vein Cannulation · ICRA 2018 |
Methods — techniques the papers use, named apart from their topics
optical coherence tomography · 0.7fiber bragg grating sensing · 0.7detection algorithm · 0.3bioimpedance sensing · 0.3
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2018 | Innovative Bio-Impedance Sensor Towards Puncture Detection in Eye Surgery for Retinal Vein Occlusion TreatmentabstractAt the moment, surgeons struggle curing a widespread eye disease known as retinal vein occlusion where clots obstruct the retinal vessels. Latter vascular disorder involves black spots in people's eyesight and lead eventually to blindness. A recent promising treatment consists in flushing a thrombolytic agent inside the clotted retinal vessels. The surgery implies puncturing vessels ranging from 50 to 400 microns diameter on the backside of the eye, namely the retina. Latest research succeeded in tackling several challenges around this operation: the surgeon's hand tremor and the high precision required amongst other requirements. Despite several breakthroughs, the surgeon only relies on a microscope to perform the surgery through the patient eye's lens, giving poor depth perception to properly puncture the retinal vessels. This way, the surgeon is most likely to pierce through the vessel and inject the thrombolytic drug under the retina, which would endanger the person's eyesight. In this paper, we investigate the use of a novel bio-impedance sensor developed for eye surgery. Together with this new sensor, a detection algorithm has been developed to detect the puncture and double puncture events to give a feedback to the operator of the system. As far as we are aware of, such technology doesn't exist yet in eye surgery to tackle the depth perception question. This paper aims at demonstrating the benefits of this technology. Laurent Schoevaerdts, Laure Esteveny, Gianni Borghesan, Mouloud Ourak, A. Gijbels, Jonas Smits, Dominiek Reynaerts, Emmanuel B. Vander Poorten |
ICRA | 1 |
| 2018 | Development and Experimental Validation of a Combined FBG Force and OCT Distance Sensing Needle for Robot-Assisted Retinal Vein CannulationabstractRetinal Vein Occlusion is a common retinal vascular disorder which can cause severe loss of vision. Retinal vein cannulation followed by injection of an anti-coagulant into the affected vein is a promising treatment. However, given the scale and fragility of the surgical workfield, this procedure is considered too high-risk to perform manually. A first successful robot-assisted procedure has been demonstrated. Even though successful, the procedure remains extremely challenging. This paper aims at providing a solution for the limited perception of instrument-tissue interaction forces as well as depth estimation during retinal vein cannulation. The development of a novel combined force and distance sensing cannulation needle relying on Fiber Bragg grating (FBG) and Optical Coherence Tomography (OCT) A-scan technology is reported. The design, the manufacturing process, the calibration method, and the experimental characterization of the produced sensor are discussed. The functionality of the combined sensing modalities and the real-time distance estimation algorithm are validated respectively on in-vitro and ex-vivo models. Jonas Smits, Mouloud Ourak, A. Gijbels, Laure Esteveny, Gianni Borghesan, Laurent Schoevaerdts, Koen Willekens, Peter Stalmans, Eva Lankenau, Hinnerk Schulz-Hildebrandt, Gereon Hüttmann, Dominiek Reynaerts, Emmanuel B. Vander Poorten |
ICRA | 6 |