Demo Data from SIGIR 2026 / reviewers in the wild / expert
Sizhen Bian
dblp:229/1651
· DBLP profile ↗
6ranked-venue papers
1as first author
4since 2021 · last 2025
0000-0001-6760-5539ORCID · verified
Domains — the database's venue-derived domains; a paper can count in several
Human-computer interaction and ubiquitous computing · 3 · 1 first-author · 1 since 2021Systems, architecture and hardware · 2 · 2 since 2021Computer networks · 1 · 1 since 2021Software engineering, systems software and programming languages · 1 · 1 since 2021
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Human-computer interaction and pervasive computing
1 paper |
Interaction techniques and input · 38% Ubiquitous computing and smart environments · 38% Health and well-being technologies · 12% |
Topics — the 4 heaviest of 5, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Ubiquitous computing and smart environments › context recognition
activity recognition |
0.4 | 1 | 2019 | Passive Capacitive based Approach for Full Body Gym Workout Recognition and Counting · PerCom 2019 |
Interaction techniques and input › input sensing
capacitive sensing |
0.4 | 1 | 2019 | Passive Capacitive based Approach for Full Body Gym Workout Recognition and Counting · PerCom 2019 |
Wearable and physiological sensing › activity tracking
exercise recognition |
0.1 | 1 | 2019 | Passive Capacitive based Approach for Full Body Gym Workout Recognition and Counting · PerCom 2019 |
Health and well-being technologies › physical activity
fitness tracking |
0.1 | 1 | 2019 | Passive Capacitive based Approach for Full Body Gym Workout Recognition and Counting · PerCom 2019 |
Methods — techniques the papers use, named apart from their topics
capacitive coupling sensing · 0.4
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2025 | Multi-Partner Project: Sustainable Textile Electronics (STELEC)abstractE-textiles are rapidly emerging as an important area of electronic circuit applications. It also facilitates many socially important applications such as personalized health, elderly care, and smart agriculture. However, the environmental impact and sustainability of e-textiles remain very problematic. STELEC, short for Sustainable Textile ELECtronics, is an interdisciplinary research project funded by the European Innovation Council (EIC) under the Pathfinder programme on the responsible elec-tronics topic seeking cutting-edge innovation. STELEC started in September 2024 and is in its initial stage. The project is a multinational collaboration of research institutes, universities and companies across Europe. It aims at developing next-generation textile-based electronics in applications from sensing, processing to AI, with a commitment to full lifecycle sustainability. Bo Zhou 0005, Mengxi Liu 0004, Sizhen Bian, Daniel Geißler, Paul Lukowicz, José Miranda 0001, Jonathan Dan, David Atienza 0001, Mohamed Amine Riahi, Norbert Wehn, Russel N. Torah, Sheng Yong, Stephen P. Beeby, Magdalena Kohler, Berit Greinke, Junchun Yu, Vincent Nierstrasz, Leila Sheldrick, Rebecca Stewart, Tommaso Nieri, Matteo Maccanti, Daniele S. Spinelli |
DATE | 3 |
| 2025 | iBreath: Usage of Breathing Gestures as Means of Interactions MHCI016abstractBreathing is a spontaneous but controllable body function that can be used for hands-free interaction. Our work introduces “iBreath”, a novel system to detect breathing gestures similar to clicks using bio-impedance. We evaluated iBreath’s accuracy and user experience using two lab studies (n=34). Our results show high detection accuracy (F1-scores > 95.2%). Furthermore, the users found the gestures easy to use and comfortable. Thus, we developed eight practical guidelines for the future development of breathing gestures. For example, designers can train users on new gestures within just 50 seconds (five trials), and achieve robust performance with both user-dependent and user-independent models trained on data from 21 participants, each yielding accuracies above 90%. Users preferred single clicks and disliked triple clicks. The median gesture duration is 3.5-5.3 seconds. Our work provides solid ground for researchers to experiment with creating breathing gestures and interactions. Mengxi Liu 0004, Daniel Geißler, Deepika Gurung, Hymalai Bello, Bo Zhou 0005, Sizhen Bian, Paul Lukowicz, Passant El Agroudy |
Proc. ACM Hum. Comput. Interact. | 6 |
| 2024 | Worker Activity Recognition in Manufacturing Line Using Near-Body Electric FieldabstractManufacturing industries strive to improve production efficiency and product quality by deploying advanced sensing and control systems. Wearable sensors are emerging as a promising solution for achieving this goal, as they can provide continuous and unobtrusive monitoring of workers’ activities in the manufacturing line. This article presents a novel wearable sensing prototype that combines IMU and body capacitance sensing modules to recognize worker activities in the manufacturing line. To handle these multimodal sensor data, we propose and compare early, and late sensor data fusion approaches for multichannel time-series convolutional neural networks and deep convolutional LSTM. We evaluate the proposed hardware and neural network model by collecting and annotating sensor data using the proposed sensing prototype and Apple Watches in the testbed of the manufacturing line. Experimental results demonstrate that our proposed methods achieve superior performance compared to the baseline methods, indicating the potential of the proposed approach for real-world applications in manufacturing industries. Furthermore, the proposed sensing prototype with a body capacitive sensor (BCS) and feature fusion method improves by 6.35%, yielding a 9.38% higher macro F1 score than the proposed sensing prototype without a BCS and Apple Watch data, respectively. Sungho Suh, Vitor F. Rey, Sizhen Bian, Yu-Chi Huang, Joze M. Rozanec, Hooman Tavakoli, Bo Zhou 0005, Paul Lukowicz |
IEEE Internet Things J. | 3 |
| 2023 | ColibriES: A Milliwatts RISC-V Based Embedded System Leveraging Neuromorphic and Neural Networks Hardware Accelerators for Low-Latency Closed-loop Control ApplicationsabstractEnd-to-end event-based computation has the poten-tial to push the envelope in latency and energy efficiency for edge AI applications. Unfortunately, event-based sensors (e.g., DVS cameras) and neuromorphic spike-based processors (e.g., Loihi) have been designed in a decoupled fashion, thereby missing major streamlining opportunities. This paper presents ColibriES, the first-ever neuromorphic hardware embedded system plat-form with dedicated event-sensor interfaces and full processing pipelines. ColibriES includes event and frame interfaces and data processing, aiming at efficient and long-life embedded systems in edge scenarios. ColibriES is based on the Kraken system-on-chip and contains a heterogeneous parallel ultra-low power (PULP) processor, frame-based and event-based camera interfaces, and two hardware accelerators for the computation of both event-based spiking neural networks and frame-based ternary convolutional neural networks. This paper explores and accurately evaluates the performance of event data processing on the example of gesture recognition on ColibriES, as the first step of full-system evaluation. In our experiments, we demonstrate a chip energy consumption of 7.7 mJ and latency of 164.5 ms of each inference with the DVS Gesture event data set as an example for closed-loop data processing, showcasing the potential of ColibriES for battery-powered applications such as wearable devices and UAVs that require low-latency closed-loop control. Georg Rutishauser, Robin Hunziker, Alfio Di Mauro, Sizhen Bian, Luca Benini, Michele Magno |
ISCAS | 4 |
| 2020 | Finger Air Writing - Movement Reconstruction with Low-cost IMU SensorabstractIn this paper, we present and evaluate a method for trajectory reconstruction from IMU signals generated when a person ”air writes” text with a finger worn IMU to make the resulting text as human-readable as possible. The vision is to provide a virtual ”sticky note” allowing people to digitally attach simple texts to locations. Thus, for example, we envision a person walking by someone’s locked office door and simply air writing, ”let me know when you are back”. The other person would then have, for example, their phone vibrate when they come into the office and would see the message on their screen. The problem that we address is how to extract from such ”air writing”, performed without visual feedback or a real surface to write, de-noised 2D trajectories that can be later displayed on a screen in a way that is well readable to humans. We describe the sensor and its signals, the trajectory extraction algorithm, and a user study that shows that we can achieve a high degree of readability. Junaid Younas, Hector Margarito, Sizhen Bian, Paul Lukowicz |
MobiQuitous | 3 |
| 2019 | Passive Capacitive based Approach for Full Body Gym Workout Recognition and CountingabstractIn this work, we present the design and implementation of a micro watt level power consumption, human body capacitance based sensor for recognizing and counting gym workouts. The concept also works when the device is attached to a body part which is not directly involved in the activity's movement. In contrast, most of the widely used motion sensing based approaches require placing the sensor on the moving body part (e.g. for analyzing leg based gym exercises the sensor needs to be placed on the leg). We described the physical principle behind the ubiquitous electric coupling between human body and environment, and explored the capability of this sensing modality in gym workouts. We evaluated our sensor with 11 subjects, performing 7 popular gym workouts each day over 5 days with our sensor being placed at 3 different body positions, including a non-contact position, where the sensor is placed in the subject's pocket. Results showed that our sensing approach achieved an average counting accuracy of 91%, which is highly competitive with commercial devices on the market. The mean leave one user out workout recognition f-scores obtained were of 63%, 56%, 45% for sensors located on wrist, on calf and in pocket, respectively. As every subject performed activities over multiple days changing shoe height, shoe and clothes type, we demonstrate that full body activity counting and to some extent recognition is feasible, regardless of personal habit of movement speed and scale. Sizhen Bian, Vitor F. Rey, Peter Hevesi, Paul Lukowicz |
PerCom | 1 |