Demo Data from SIGIR 2026 / reviewers in the wild / expert
Matthew Ng
dblp:234/9236
· DBLP profile ↗
7ranked-venue papers
2as first author
5since 2021 · last 2025
—ORCID · conflict
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 4 · 3 since 2021Artificial intelligence and machine learning · 3 · 2 first-author · 2 since 2021Systems, architecture and hardware · 3 · 2 first-author · 2 since 2021
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
3 papers |
3D vision · 33% Legged, aerial and field robots · 27% Robot navigation and mapping · 24% |
Topics — the 7 heaviest of 7, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Legged, aerial and field robots
aerial robots |
0.9 | 1 | 2025 | Collapsible Airfoil Single Actuator ROtor-Craft (CASARO) - Construction and Analysis of a Soft Rotary Wing Robot · ICRA 2025 |
Robotics › Robot navigation and mapping › state estimation
visual state estimation |
0.7 | 1 | 2023 | Direct Angular Rate Estimation Without Event Motion-Compensation At High Angular Rates · ICRA 2023 |
Computer vision › 3D vision › motion estimation
optical flow |
0.6 | 2 | 2023 | SHIFT: Selective Heading Image for Translation An onboard monocular optical flow estimator for fast constantly rotating UAVs · ICRA 2020 Direct Angular Rate Estimation Without Event Motion-Compensation At High Angular Rates · ICRA 2023 |
Computer vision › 3D vision › pose estimation
visual pose estimation |
0.4 | 1 | 2020 | SHIFT: Selective Heading Image for Translation An onboard monocular optical flow estimator for fast constantly rotating UAVs · ICRA 2020 |
Robotics › Motion planning and robot control › robot control
flight control |
0.3 | 1 | 2025 | Collapsible Airfoil Single Actuator ROtor-Craft (CASARO) - Construction and Analysis of a Soft Rotary Wing Robot · ICRA 2025 |
Robotics › Motion planning and robot control
robot control |
0.3 | 1 | 2025 | Collapsible Airfoil Single Actuator ROtor-Craft (CASARO) - Construction and Analysis of a Soft Rotary Wing Robot · ICRA 2025 |
Robotics › Robot navigation and mapping › mobile robot navigation › navigation under uncertainty
GPS-denied navigation |
0.1 | 1 | 2020 | SHIFT: Selective Heading Image for Translation An onboard monocular optical flow estimator for fast constantly rotating UAVs · ICRA 2020 |
Methods — techniques the papers use, named apart from their topics
unscented kalman filter · 1.1phase correlation · 1.1soft pneumatic actuation · 0.9fourier-based estimation · 0.7log-polar transform · 0.4
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2025 | Collapsible Airfoil Single Actuator ROtor-Craft (CASARO) - Construction and Analysis of a Soft Rotary Wing RobotabstractIn this paper, a soft rotary wing robot capable of flight and control is presented. The Collapsible Airfoil Single Actuator ROtor-craft (CASARO) is a single actuator monocopter that derives its geometric properties from the Samara seed. CASARO achieves better flight efficiency, lift, and handling ergonomics by reducing its overall volume by 91.7% when collapsed and stowed. Unlike conventional rotorcraft, CASARO uses a non-rigid fabric wing to produce lift in flight. It utilizes the robot's rotational velocity to maintain tension within its fabric and airframe, providing adequate lift during its hover state. The conception, design, construction, and control of the soft monowing are demonstrated, including its capability to reduce its footprint with its soft fabric construction. To analyze the flight dynamics of CASARO, the craft is flown indoors autonomously, tracking its wing surface, craft body attitude, and position with various step inputs to observe different wing dynamics. CASARO is also capable of being deployed outdoors for real-life human-operated flight. Wei Jun Ang, Emmanuel Tang, Matthew Ng, Shaohui Foong |
ICRA | 3 |
| 2023 | Direct Angular Rate Estimation Without Event Motion-Compensation At High Angular RatesabstractFeature-based methods are a popular method for camera state estimation using event cameras. Due to the spatiotemporal nature of events, all event images exhibit smearing of events analogous to motion blur for a camera under motion. As such, events must be motion compensated to derive a sharp event image. However, this presents a causality dilemma where motion prior is required to unsmear the events, but a sharp event image is required to estimate motion. While it is possible to use the IMU to develop motion prior, it has been shown that the limited dynamic range of$\pm \mathbf{2000}^{\circ}/\mathrm{s}$is insufficient for high angular rate rotorcrafts. Furthermore, smoothing of motion-compensated images due to actual event detection time latency in event cameras severely limits the performance of feature-based methods at high angular rates. This paper proposes a Fourier-based angular rate estimator capable of estimating angular rates directly on non-motion compensated event images. This method circumvents the need for external motion priors in camera state estimation and sidesteps problematic smoothing of features in the spatial domain due to motion blur. Lastly, using an NVIDIA Jetson Xavier NX, the algorithm is demonstrated to be real-time performant up to 3960°/s. Matthew Ng, Xinyu Cai, Shaohui Foong |
ICRA | 1 |
| 2022 | Cardiac MRI segmentation with sparse annotations: Ensembling deep learning uncertainty and shape priors
Fumin Guo, Matthew Ng, Grey Kuling, Graham A. Wright |
Medical Image Anal. | 2 |
| 2021 | Loss odyssey in medical image segmentation
Jun Ma 0016, Jianan Chen 0001, Matthew Ng, Yu Li 0031, Xiaoping Yang 0001, Anne L. Martel |
Medical Image Anal. | 3 |
| 2021 | Left Ventricle Quantification Challenge: A Comprehensive Comparison and Evaluation of Segmentation and Regression for Mid-Ventricular Short-Axis Cardiac MR DataabstractAutomatic quantification of the left ventricle (LV) from cardiac magnetic resonance (CMR) images plays an important role in making the diagnosis procedure efficient, reliable, and alleviating the laborious reading work for physicians. Considerable efforts have been devoted to LV quantification using different strategies that include segmentation-based (SG) methods and the recent direct regression (DR) methods. Although both SG and DR methods have obtained great success for the task, a systematic platform to benchmark them remains absent because of differences in label information during model learning. In this paper, we conducted an unbiased evaluation and comparison of cardiac LV quantification methods that were submitted to the Left Ventricle Quantification (LVQuan) challenge, which was held in conjunction with the Statistical Atlases and Computational Modeling of the Heart (STACOM) workshop at the MICCAI 2018. The challenge was targeted at the quantification of 1) areas of LV cavity and myocardium, 2) dimensions of the LV cavity, 3) regional wall thicknesses (RWT), and 4) the cardiac phase, from mid-ventricle short-axis CMR images. First, we constructed a public quantification dataset Cardiac-DIG with ground truth labels for both the myocardium mask and these quantification targets across the entire cardiac cycle. Then, the key techniques employed by each submission were described. Next, quantitative validation of these submissions were conducted with the constructed dataset. The evaluation results revealed that both SG and DR methods can offer good LV quantification performance, even though DR methods do not require densely labeled masks for supervision. Among the 12 submissions, the DR method LDAMT offered the best performance, with a mean estimation error of 301 mm2for the two areas, 2.15 mm for the cavity dimensions, 2.03 mm for RWTs, and a 9.5% error rate for the cardiac phase classification. Three of the SG methods also delivered comparable performances. Finally, we discussed the advantages and disadvantages of SG and DR methods, as well as the unsolved problems in automatic cardiac quantification for clinical practice applications. Wufeng Xue, Jiahui Li 0005, Eric Kerfoot, James R. Clough, Ilkay Öksüz, Vicente Grau, Fumin Guo, Matthew Ng, Xiang Li 0001, Quanzheng Li, Lihong Liu, Ilias Grinias, Georgios Tziritas, Angélica Atehortúa, Mireille Garreau, Yeonggul Jang, Alejandro Debus, Enzo Ferrante, Guanyu Yang 0001, Tiancong Hua, Shuo Li 0001 |
IEEE J. Biomed. Health Informatics | 10 |
| 2020 | SHIFT: Selective Heading Image for Translation An onboard monocular optical flow estimator for fast constantly rotating UAVsabstractPose estimation is of paramount importance for flight control as well as localization and navigation of Unmanned Aerial Vehicles (UAVs) to enable autonomous operations. In environments without GPS, such estimation can only be determined using onboard sensors; optical flow using a monocular camera is a popular approach. Monocopters are a class of nature inspired UAVs known as free rotors where their design and flight dynamics are inspired by the falling samara seed. With a constantly rotating body frame, free rotors introduces some unique challenges for visual perception required during optical flow sensing. This paper addresses these problems with the introduction of SHIFT (Selective Heading Image for Translation) that selects optimal images for determining translation with optical flow. It achieves this by decoupling rotation vectors about the optical axis from translation vectors in a flow field through the separate tracking of orientation and position using an Unscented Kalman Filter with phase correlation in the log-polar and spatial domain. The experiments show that SHIFT's estimation in orientation is stable even under sinusoidal excitation with a median absolute percentage errors of less than 1%. It is able to track position and orientation of a UAV accurately. Matthew Ng, Emmanuel Tang, Gim Song Soh, Shaohui Foong |
ICRA | 1 |
| 2020 | Improving cardiac MRI convolutional neural network segmentation on small training datasets and dataset shift: A continuous kernel cut approach
Fumin Guo, Matthew Ng, Maged Goubran, Steffen E. Petersen, Stefan K. Piechnik, Stefan Neubauer, Graham A. Wright |
Medical Image Anal. | 2 |