Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Jong Hyun Lim

dblp:24/137 · DBLP profile ↗
← Back
4ranked-venue papers
2as first author
0since 2021 · last 2011
—ORCID · unresolved

Domains — the database's venue-derived domains; a paper can count in several

Computer networks · 3 · 2 first-authorSystems, architecture and hardware · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer networks
1 paper
Internet of things and sensor networks · 50% Wireless networking · 50%
Human-computer interaction and pervasive computing
1 paper
Health and well-being technologies · 77% Ubiquitous computing and smart environments · 23%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 3 heaviest of 5, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Wireless networking
qos
0.112008
MEDiSN: medical emergency detection in sensor networks · SenSys 2008
Internet of things and sensor networks
wireless sensor network
0.112008
MEDiSN: medical emergency detection in sensor networks · SenSys 2008
Medical and health informatics › clinical monitoring
patient monitoring
0.012008
MEDiSN: medical emergency detection in sensor networks · SenSys 2008

Methods — techniques the papers use, named apart from their topics

encryption · 0.2data compression · 0.2
YearPublicationVenuePosition
2011 Poster: HealthOS: a platform for integrating and developing pervasive healthcare applications
abstract
No abstract available.
Jong Hyun Lim, Andong Zhan, Andreas Terzis
MobiSys1
2010 Tracking a non-cooperative mobile target using low-power pulsed Doppler radars
abstract
Most target tracking applications developed for wireless sensor networks thus far employ passive sensors which detect the target's emissions. Their performance is thereby dictated by the magnitude of the target's signal and the receivers' sensitivity. Instead, we propose using a network of low-power Doppler radars that actively measure the target's radial velocity. Nodes combine their measurements to solve a system of nonlinear equations that estimate the target's position and velocity. Because these equations have no closed-form solutions we solve them using numerical methods. These methods however can lead to local minima or even diverge in the presence of even small measurement noise. For this reason we couple the proposed numerical method with an Extended Kalman filter that models the target's movement along a straight line. Clearly the target does not always follow a linear path and so we augment this simple Kalman filter with a method that detects the target's turns and updates the filter's dynamical model accordingly. The combination of the two approaches improve tracking accuracy compared to the numerical solution alone. Results from simulations and a prototype implementation suggest that the combined solution can effectively track a mobile target with average localization error as low as 25 cm in a 10×10 m outdoor field.
Jong Hyun Lim, Andreas Terzis, I-Jeng Wang
LCN1
2010 MEDiSN: Medical emergency detection in sensor networks
abstract
Staff shortages and an increasingly aging population are straining the ability of emergency departments to provide high quality care. At the same time, there is a growing concern about hospitals' ability to provide effective care during disaster events. For these reasons, tools that automate patient monitoring have the potential to greatly improve efficiency and quality of health care. Towards this goal, we have developed MEDiSN , a wireless sensor network for monitoring patients' physiological data in hospitals and during disaster events. MEDiSN comprises Physiological Monitors (PMs), which are custom-built, patient-worn motes that sample, encrypt, and sign physiological data and Relay Points (RPs) that self-organize into a multi-hop wireless backbone for carrying physiological data. Moreover, MEDiSN includes a back-end server that persistently stores medical data and presents them to authenticated GUI clients. The combination of MEDiSN's two-tier architecture and optimized rate control protocols allows it to address the compound challenge of reliably delivering large volumes of data while meeting the application's QoS requirements. Results from extensive simulations, testbed experiments, and multiple pilot hospital deployments show that MEDiSN can scale from tens to at least five hundred PMs, effectively protect application packets from congestive and corruptive losses, and deliver medically actionable data.
JeongGil Ko, Jong Hyun Lim, Yin Chen 0002, Rvazvan Musvaloiu-E, Andreas Terzis, Gerald M. Masson, Tia Gao, Walt Destler, Leo Selavo, Richard P. Dutton
ACM Trans. Embed. Comput. Syst.2
2008 MEDiSN: medical emergency detection in sensor networks
abstract
Staff shortages and an increasingly aging population are straining the ability of emergency departments to provide high-quality care. Moreover, there is a growing concern about the ability of hospitals to provide effective care during disaster events. Tools that automate patient monitoring would greatly improve efficiency, quality of care, and the volume of patients treated. Towards this goal, we have developed MEDiSN, a wireless sensor network for monitoring patients' vital signs in hospitals and disaster events. MEDiSN consists of Patient Monitors which are custom-built, patient-worn motes that sample, compress and secure medical data, and Relay Points that form a static multi-hop wireless backbone for carrying patient data. Moreover, MEDiSN includes a back-end server that persistently stores medical data and presents them to multiple GUI clients. MEDiSN's heterogeneous architecture enables it to address the compound challenge of reliably delivering large volumes of data while meeting the application's QoS requirements.
JeongGil Ko, Razvan Musaloiu-Elefteri, Jong Hyun Lim, Yin Chen 0002, Andreas Terzis, Tia Gao, Walt Destler, Leo Selavo
SenSys3