Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Kelsey A. Muller

dblp:246/7966 · DBLP profile ↗
← Back
1ranked-venue papers
0as first author
0since 2021 · last 2019
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 1Systems, architecture and hardware · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Human-computer interaction and pervasive computing
1 paper
Accessibility and assistive technology · 56% Haptics and multimodal interaction · 44%

Topics — the 3 heaviest of 3, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Accessibility and assistive technology › prosthetics
prosthetic hand
0.412019
The (Sensorized) Hand is Quicker than the Eye: Restoring Grasping Speed and Confidence for Amputees with Tactile Reflexes · ICRA 2019
Haptics and multimodal interaction
tactile sensing
0.412019
The (Sensorized) Hand is Quicker than the Eye: Restoring Grasping Speed and Confidence for Amputees with Tactile Reflexes · ICRA 2019
Accessibility and assistive technology › prosthetics
upper limb prosthetics
0.112019
The (Sensorized) Hand is Quicker than the Eye: Restoring Grasping Speed and Confidence for Amputees with Tactile Reflexes · ICRA 2019

Methods — techniques the papers use, named apart from their topics

tactile reflex controller · 0.4foam pressure sensing · 0.4
YearPublicationVenuePosition
2019 The (Sensorized) Hand is Quicker than the Eye: Restoring Grasping Speed and Confidence for Amputees with Tactile Reflexes
abstract
Myoelectric prosthetic hand users have difficulty with, and frequently avoid, grasping fragile objects with their prosthesis. While the sense of touch is known to be critical for human hand dexterity, it has been virtually absent in prosthetic hands. In this study, a standard myoelectric prosthetic hand was modified with tactile sensors and a simple tactile reflex to inhibit excessive forces on contact. The tactile sensors were made from an open-cell self-skinning polyurethane foam that produced a detectable increase in air pressure inside the foam when contacted. This contact signal was then used by an inhibitory reflex controller which served to reduce the gain of weaker closing signals after contact but allow stronger closing signals to pass through. Four unilateral myoelectric prosthesis users completed five trials of three different timed grasping tasks with fragile and rigid items. Subjects performed each task in three different scenarios: with their sound side limb, their current myoelectric hand, and the modified prosthesis with tactile reflex. Findings demonstrated that grasping performance with fragile objects was significantly enhanced using the modified prosthesis, even nearing the performance of subject's sound side limb. Results suggest that this approach can substantially improve the speed and success of grasping fragile items, leading to improved use patterns, decreased cognitive effort, and improved user confidence.
Jeremy A. Fishel, Blaine Matulevich, Kelsey A. Muller, Gary M. Berke
ICRA3