Demo Data from SIGIR 2026 / reviewers in the wild / expert
Eric Bennison
dblp:273/1307
· DBLP profile ↗
1ranked-venue papers
1as first author
0since 2021 · last 1973
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Computer networks · 1 · 1 first-author
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Computer networks
1 paper |
Physical-layer communications · 100% |
Topics — the 1 heaviest of 2, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Physical-layer communications › transmission media
transmission line |
0.0 | 1 | 1973 | Lightning Surges in Open Wire, Coaxial, and Paired Cables · IEEE Trans. Commun. 1973 |
Methods — techniques the papers use, named apart from their topics
oscillography · 0.0field measurement · 0.0
| Year | Publication | Venue | Position |
|---|---|---|---|
| 1973 | Lightning Surges in Open Wire, Coaxial, and Paired CablesabstractDuring the 1968 and 1969 lightning seasons, member companies of the Telephone Association of Canada conducted a field investigation of lightning voltages induced in outside plant toll facilities at ten selected sites across Canada. Oscillograms of longitudinal surge voltages occurring in open wire, paired, and coaxial cable were continuously photographed with an automatic camera system especially developed for the investigation during each season. On completion, approximately 10 000 useful surge photographs were obtained and analyzed. The results indicate that a standard test wave, with 1000-V peak and10 \times 1000-\mus waveshape, simulates 99.8 percent of the lightning surges encountered in paired and coaxial cables. For open wire circuits, a more suitable test wave with 2000-V peak amplitude and4 \times 200-\mus waveshape is required to simulate 99.8 percent of the lightning surges. The number of surges per storm was found to be far higher than previously assumed. The highest recorded incidence during a storm was 484 surges greater than 10 V. Surge repetition intervals were short in all three types of facility; about 15 percent were less than 2 s. The surge information presented provides fundamental data on lightning surge effects in Canadian telephone plants which were previously unavailable. The assembled data will be of value to the protection engineer when designing future protection systems, and also to the transmission engineer concerned with noise problems. Eric Bennison, Axel J. Ghazi, Pierre Ferland |
IEEE Trans. Commun. | 1 |