Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Eric Bennison

dblp:273/1307 · DBLP profile ↗
← Back
1ranked-venue papers
1as first author
0since 2021 · last 1973
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Computer networks · 1 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer networks
1 paper
Physical-layer communications · 100%

Topics — the 1 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Physical-layer communications › transmission media
transmission line
0.011973
Lightning Surges in Open Wire, Coaxial, and Paired Cables · IEEE Trans. Commun. 1973

Methods — techniques the papers use, named apart from their topics

oscillography · 0.0field measurement · 0.0
YearPublicationVenuePosition
1973 Lightning Surges in Open Wire, Coaxial, and Paired Cables
abstract
During the 1968 and 1969 lightning seasons, member companies of the Telephone Association of Canada conducted a field investigation of lightning voltages induced in outside plant toll facilities at ten selected sites across Canada. Oscillograms of longitudinal surge voltages occurring in open wire, paired, and coaxial cable were continuously photographed with an automatic camera system especially developed for the investigation during each season. On completion, approximately 10 000 useful surge photographs were obtained and analyzed. The results indicate that a standard test wave, with 1000-V peak and10 \times 1000-\mus waveshape, simulates 99.8 percent of the lightning surges encountered in paired and coaxial cables. For open wire circuits, a more suitable test wave with 2000-V peak amplitude and4 \times 200-\mus waveshape is required to simulate 99.8 percent of the lightning surges. The number of surges per storm was found to be far higher than previously assumed. The highest recorded incidence during a storm was 484 surges greater than 10 V. Surge repetition intervals were short in all three types of facility; about 15 percent were less than 2 s. The surge information presented provides fundamental data on lightning surge effects in Canadian telephone plants which were previously unavailable. The assembled data will be of value to the protection engineer when designing future protection systems, and also to the transmission engineer concerned with noise problems.
Eric Bennison, Axel J. Ghazi, Pierre Ferland
IEEE Trans. Commun.1