Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Hubert Kim

dblp:274/9738 · DBLP profile ↗
← Back
1ranked-venue papers
1as first author
0since 2021 · last 2020
—ORCID · unresolved

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 1 · 1 first-authorSystems, architecture and hardware · 1 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Human-computer interaction and pervasive computing
1 paper
Haptics and multimodal interaction · 87% Human-robot interaction · 13%

Topics — the 3 heaviest of 3, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Haptics and multimodal interaction
just noticeable difference
0.412020
Just Noticeable Differences for Joint Torque Feedback During Static Poses · ICRA 2020
Haptics and multimodal interaction › haptic feedback
kinesthetic feedback
0.412020
Just Noticeable Differences for Joint Torque Feedback During Static Poses · ICRA 2020
Human-robot interaction › wearable robot
exoskeleton
0.112020
Just Noticeable Differences for Joint Torque Feedback During Static Poses · ICRA 2020

Methods — techniques the papers use, named apart from their topics

psychophysical staircase method · 0.4
YearPublicationVenuePosition
2020 Just Noticeable Differences for Joint Torque Feedback During Static Poses
abstract
Joint torque feedback is a new and promising means of kinesthetic feedback for providing information to a person or guiding them during a motion task. However, little work has been done in determining the psychophysical parameters of how well humans can detect external torques. In this study, we determine the human perceptual ability to detect kinesthetic feedback at the elbow during all possible combinations of preload torques and test stimulus torques, with the elbow in a static posture. To accomplish this, we constructed an exoskeleton for the elbow providing joint torque feedback. The device is designed to convey 0.54 Nm of stall torque for up to 120 seconds via a semi-rigid sleeve structure. Using this device, we assessed perception capability using the Interweaving Staircase Method. We found that users could detect average torques of 0.14-0.18 Nm in the extension or flexion directions with no preload. When a preload of 1.27 Nm was applied, this increased to 0.25-0.27 Nm for when flexion stimuli were applied, and 0.180.3 Nm when extension stimuli were applied, depending on the preload direction.
Hubert Kim, Hongxu H. Guo, Alan T. Asbeck
ICRA1