Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Oscar H. Tovar

dblp:317/6428 · DBLP profile ↗
← Back
1ranked-venue papers
0as first author
0since 2021 · last 1996
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 2 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics
cardiac electrophysiology
0.011996
The mechanism of defibrillation and cardioversion · Proc. IEEE 1996
Medical and health informatics › medical devices
implantable cardioverter defibrillator
0.011996
The mechanism of defibrillation and cardioversion · Proc. IEEE 1996
YearPublicationVenuePosition
1996 The mechanism of defibrillation and cardioversion
abstract
Sudden cardiac death due to ventricular fibrillation is responsible for over 400,000 deaths per year in the United States alone. The only treatment for this fatal arrhythmia is electrical defibrillation of the ventricle. During the initial seconds of ventricular fibrillation, multiple reentry circuits cause action potentials to occur rapidly with a cycle length determined primarily by the cellular refractory period. A successful defibrillation shock stimulates cells during the refractory period to produce a prolonged postshock response throughout the ventricle. The ventricle is then refractory to propagating fibrillation wavefronts and fibrillation ceases. Biphasic defibrillator waveforms, formed by reversing the polarity partway through the shock, lower defibrillation threshold significantly thereby allowing nonthoracotomy implantation of implantable cardioverter-defibrillators (ICDs). These waveforms appear to defibrillate at lower shock intensities primarily because sodium channel recovery from inactivation by the first phase of the waveform allows the shock to produce the required prolonged responses at these lower intensities. Defibrillation becomes much more difficult at the longer fibrillation durations encountered in "out-of-hospital" cardiac arrest, due to changes in fibrillation morphology. Recent studies suggest that sodium channel recovery produced by biphasic waveforms may also have the potential to increase probability of successful resuscitation under these more stringent conditions.
Janice L. Jones, Oscar H. Tovar
Proc. IEEE2