Demo Data from SIGIR 2026 / reviewers in the wild / expert
Alexandru Stanimir
dblp:33/560
· DBLP profile ↗
2ranked-venue papers
0as first author
0since 2021 · last 2003
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 2Graphics, computer vision, multimedia, augmented reality and games · 1
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% | |
| Artificial intelligence
1 paper |
Robot manipulation · 100% |
Topics — the 2 heaviest of 2, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Medical and health informatics
medical robotics |
0.0 | 1 | 2003 | AcuBot: a robot for radiological interventions · IEEE Trans. Robotics Autom. 2003 |
Robotics › Robot manipulation › medical robotics
needle manipulation |
0.0 | 1 | 2003 | AcuBot: a robot for radiological interventions · IEEE Trans. Robotics Autom. 2003 |
Methods — techniques the papers use, named apart from their topics
fluoroscopy · 0.1decoupled motion control · 0.1CT imaging · 0.1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2003 | AcuBot: a robot for radiological interventionsabstractWe report the development of a robot for radiological percutaneous interventions using uniplanar fluoroscopy, biplanar fluoroscopy, or computed tomography (CT) for needle biopsy, radio frequency ablation, cryotherapy, and other needle procedures. AcuBot is a compact six-degree-of-freedom robot for manipulating a needle or other slender surgical instrument in the confined space of the imager without inducing image artifacts. Its distinctive characteristic is its decoupled motion capability correlated to the positioning, orientation, and instrument insertion steps of the percutaneous intervention. This approach allows each step of the intervention to be performed using a separate mechanism of the robot. One major advantage of this kinematic approach is patient safety. The first feasibility experiment performed with the robot, a cadaver study of perispinal blocks under biplanar fluoroscopy, is presented. The main expected application of this system is to CT-based procedures. AcuBot has received Food and Drug Administration clearance (IDE G010331/S1), and a clinical trial of using the robot for perispinal nerve and facet blocks is presently underway at Georgetown University, Washington, DC. Dan Stoianovici, Kevin Cleary, Alexandru Patriciu, Dumitru Mazilu, Alexandru Stanimir, Nicolae Craciunoiu, Vance Watson, Louis R. Kavoussi |
IEEE Trans. Robotics Autom. | 5 |
| 2000 | Motion-Based Robotic Instrument Targeting under C-Arm Fluoroscopy
Alexandru Patriciu, Dan Stoianovici, Louis L. Whitcomb, Thomas Jarrett, Dumitru Mazilu, Alexandru Stanimir, Iulian Iordachita, James H. Anderson, Russell H. Taylor, Louis R. Kavoussi |
MICCAI | 6 |