Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Jared Lawson

dblp:345/8458 · DBLP profile ↗
← Back
1ranked-venue papers
1as first author
1since 2021 · last 2023
—ORCID · unresolved

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 1 · 1 first-author · 1 since 2021Systems, architecture and hardware · 1 · 1 first-author · 1 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
1 paper
3D vision · 62% Motion planning and robot control · 19% Robot manipulation · 19%

Topics — the 3 heaviest of 3, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Computer vision › 3D vision
pose estimation
0.712023
Model-Based Pose Estimation of Steerable Catheters under Bi-Plane Image Feedback · ICRA 2023
Robotics › Robot manipulation › medical robotics
catheter steering
0.212023
Model-Based Pose Estimation of Steerable Catheters under Bi-Plane Image Feedback · ICRA 2023
Robotics › Motion planning and robot control
robot control
0.212023
Model-Based Pose Estimation of Steerable Catheters under Bi-Plane Image Feedback · ICRA 2023

Methods — techniques the papers use, named apart from their topics

kinematics reconstruction · 0.7bi-plane image feedback · 0.7
YearPublicationVenuePosition
2023 Model-Based Pose Estimation of Steerable Catheters under Bi-Plane Image Feedback
abstract
Small catheters undergo significant torsional deflections during endovascular interventions. A key challenge in enabling robot control of these catheters is the estimation of their bending planes. This paper considers approaches for estimating these bending planes based on bi-plane image feedback. The proposed approaches attempt to minimize error between either the direct (position-based) or instantaneous (velocity-based) kinematics with the reconstructed kinematics from bi-plane image feedback. A comparison between these methods is carried out on a setup using two cameras in lieu of a bi-plane fluoroscopy setup. The results show that the position-based approach is less susceptible to segmentation noise and works best when the segment is in a non-straight configuration. These results suggest that estimation of the bending planes can be accompanied with errors under 30°. Considering that the torsional buildup of these catheters can be more than 180°, we believe that this method can be used for catheter control with improved safety due to the reduction of this uncertainty.
Jared Lawson, Rohan Chitale, Nabil Simaan
ICRA1