Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Frigyes Samuel Racz

dblp:348/2025 · DBLP profile ↗
← Back
3ranked-venue papers
0as first author
3since 2021 · last 2025
0000-0001-9077-498XORCID · reported

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 3 · 3 since 2021Systems, architecture and hardware · 3 · 3 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Human-computer interaction and pervasive computing
2 papers
Human-robot interaction · 54% Usability and user experience research · 20% Health and well-being technologies · 20%

Topics — the 6 heaviest of 6, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Human-robot interaction
physical human-robot interaction
0.912025
Towards Evaluating the User Comfort and Experience of a Novel Steerable Drilling Robotic System in Pedicle Screw Fixation Procedures: A User Study · ICRA 2025
Usability and user experience research › cognitive load
cognitive load assessment
0.712023
CogniDaVinci: Towards Estimating Mental Workload Modulated by Visual Delays During Telerobotic Surgery - An EEG-based Analysis · ICRA 2023
Health and well-being technologies
surgical robotics
0.712023
CogniDaVinci: Towards Estimating Mental Workload Modulated by Visual Delays During Telerobotic Surgery - An EEG-based Analysis · ICRA 2023
Human-robot interaction › teleoperation
telerobotic surgery
0.712023
CogniDaVinci: Towards Estimating Mental Workload Modulated by Visual Delays During Telerobotic Surgery - An EEG-based Analysis · ICRA 2023
Human-robot interaction › healthcare robotics
robot-assisted surgery
0.312025
Towards Evaluating the User Comfort and Experience of a Novel Steerable Drilling Robotic System in Pedicle Screw Fixation Procedures: A User Study · ICRA 2025
Wearable and physiological sensing
electroencephalography
0.212023
CogniDaVinci: Towards Estimating Mental Workload Modulated by Visual Delays During Telerobotic Surgery - An EEG-based Analysis · ICRA 2023

Methods — techniques the papers use, named apart from their topics

user study · 0.9admittance control · 0.9spectral features · 0.7riemannian geometry-based classifier · 0.7EEG · 0.7
YearPublicationVenuePosition
2025 Towards Evaluating the User Comfort and Experience of a Novel Steerable Drilling Robotic System in Pedicle Screw Fixation Procedures: A User Study
abstract
Aiming at developing a safe, intuitive, and collaborative steerable drilling robotic system for pedicle screw fixation procedures, in this paper, we leverage our recently developed steerable drilling robotic framework, and developed a collaborative drilling mode to control this system. In this control mode, first a user positions a concentric tube steerable drilling robot (CT-SDR) in the workspace and aligns it based on a preplanned trajectory. Next, the CT-SDR is directly controlled by the user through an admittance mode to perform a drilling procedure and creating a J-shape tunnel. To evaluate the user comfort and intuitiveness of the drilling procedure using this system and the proposed control interface, we performed a user study with 11 subjects, who had no prior experience in using this system. The results of this study were analyzed using various qualitative and quantitative metrics.
Susheela Sharma, Frigyes Samuel Racz, Sarah Go, Siddhartha Kapuria, Omid Rezayof, Jordan P. Amadio, Mohsen Khadem, José del R. Millán, Farshid Alambeigi
ICRA2
2023 CogniDaVinci: Towards Estimating Mental Workload Modulated by Visual Delays During Telerobotic Surgery - An EEG-based Analysis
abstract
Communication latency in any delicate telerobotic operation (such as remote surgery over distance) would impose a significant challenge due to the temporal degradation of visual perception and can substantially affect the outcomes. Less is known, however, about the neurophysiological basis of how operators adapt/react to delayed visual feedback. Identification of such neural markers might provide novel ways for future applications to monitor the mental workload (MW). In this study, we recorded electroencephalography (EEG) data from nine users while performing a peg transfer task using the da Vinci Research Kit with three levels of induced visual delay in the video feedback. Our results suggest that spectral EEG-based features can provide markers of the operator's MW modulated by arbitrary visual delay. We also show that the exposure to different visual delays could be successfully classified/detected solely from EEG data, using a Riemannian geometry-based classifier, which highlights the utility of EEG signals for detecting the effect of visual delay on brain activity.
Satyam Kumar 0001, Deland Hu Liu, Frigyes Samuel Racz, Manuel Retana, Susheela Sharma, Fumiaki Iwane, Braden P. Murphy, Rory O'Keeffe, Seyed Farokh Atashzar, Farshid Alambeigi, José del R. Millán
ICRA3
2023 Characterizing the Onset and Offset of Motor Imagery During Passive Arm Movements Induced by an Upper-Body Exoskeleton
abstract
Two distinct technologies have gained attention lately due to their prospects for motor rehabilitation: robotics and brain-machine interfaces (BMIs). Harnessing their combined efforts is a largely uncharted and promising direction that has immense clinical potential. However, a significant challenge is whether motor intentions from the user can be accurately detected using non-invasive BMIs in the presence of instrumental noise and passive movements induced by the rehabilitation exoskeleton. As an alternative to the straight-forward continuous control approach, this study instead aims to characterize the onset and offset of motor imagery during passive arm movements induced by an upper-body exoskeleton to allow for the natural control (initiation and termination) of functional movements. Ten participants were recruited to perform kinesthetic motor imagery (MI) of the right arm while attached to the robot, simultaneously cued with LEDs indicating the initiation and termination of a goal-oriented reaching task. Using electroencephalogram signals, we built a decoder to detect the transition between i) rest and beginning MI and ii) maintaining and ending MI. Offline decoder evaluation achieved group average onset accuracy of 60.7% and 66.6% for offset accuracy, revealing that the start and stop of MI could be identified while attached to the robot. Furthermore, pseudo-online evaluation could replicate this performance, forecasting reliable online exoskeleton control in the future. Our approach showed that participants could produce quality and reliable sensorimotor rhythms regardless of noise or passive arm movements induced by wearing the exoskeleton, which opens new possibilities for BMI control of assistive devices.
Kanishka Mitra, Frigyes Samuel Racz, Satyam Kumar 0001, Ashish D. Deshpande, José del R. Millán
IROS2