Demo Data from SIGIR 2026 / reviewers in the wild / expert
Andrew M. Rollins
dblp:37/6413
· DBLP profile ↗
2ranked-venue papers
0as first author
0since 2021 · last 2016
0000-0002-7780-4862ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 1Graphics, computer vision, multimedia, augmented reality and games · 1Applied, interdisciplinary, general and emerging computing · 1
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% | |
| Computer graphics and multimedia
1 paper |
Visualization and visual analytics · 100% |
Topics — the 2 heaviest of 3, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Medical and health informatics › medical imaging
cardiac imaging |
0.2 | 1 | 2016 | Automated Volumetric Intravascular Plaque Classification Using Optical Coherence Tomography (OCT) · AAAI 2016 |
Medical and health informatics › retinal image analysis
optical coherence tomography analysis |
0.2 | 1 | 2016 | Automated Volumetric Intravascular Plaque Classification Using Optical Coherence Tomography (OCT) · AAAI 2016 |
Methods — techniques the papers use, named apart from their topics
machine learning · 0.5
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2016 | Automated Volumetric Intravascular Plaque Classification Using Optical Coherence Tomography (OCT)abstractAn estimated 17.5 million people died from a cardiovascular disease in 2012, representing 31% of all global deaths. Most acute coronary events result from rupture of the protective fibrous cap overlying an atherosclerotic plaque. The task of early identification of plaque types that can potentially rupture is, therefore, of great importance. The state-ofthe-art approach to imaging blood vessels is intravascular optical coherence tomography (IVOCT). However, currently, this is an offline approach where the images are first collected and then manually analyzed a frame at a time to identify regions at risk of thrombosis. This process is extremely laborious, time consuming and prone to human error. We are building a system that, when complete, will provide interactive 3D visualization of a blood vessel as an IVOCT is in progress. The visualization will highlight different plaque types and enable quick identification of regions at risk for thrombosis. In this paper, we describe our approach, focusing on machine learning methods that are a key enabling technology. Our empirical results using real OCT data show that our approach can identify different plaque types efficiently with high accuracy across multiple patients. Ronny Shalev, Daisuke Nakamura, Setsu Nishino, Andrew M. Rollins, Hiram G. Bezerra, David L. Wilson, Soumya Ray |
AAAI | 4 |
| 2015 | 3-D Stent Detection in Intravascular OCT Using a Bayesian Network and Graph SearchabstractWorldwide, many hundreds of thousands of stents are implanted each year to revascularize occlusions in coronary arteries. Intravascular optical coherence tomography is an important emerging imaging technique, which has the resolution and contrast necessary to quantitatively analyze stent deployment and tissue coverage following stent implantation. Automation is needed, as current, it takes up to 16 h to manually analyze hundreds of images and thousands of stent struts from a single pullback. For automated strut detection, we used image formation physics and machine learning via a Bayesian network, and 3-D knowledge of stent structure via graph search. Graph search was done on en face projections using minimum spanning tree algorithms. Depths of all struts in a pullback were simultaneously determined using graph cut. To assess the method, we employed the largest validation data set used so far, involving more than 8000 clinical images from 103 pullbacks from 72 patients. Automated strut detection achieved a 0.91±0.04 recall, and 0.84±0.08 precision. Performance was robust in images of varying quality. This method can improve the workflow for analysis of stent clinical trial data, and can potentially be used in the clinic to facilitate real-time stent analysis and visualization, aiding stent implantation. Zhao Wang 0003, Michael W. Jenkins, George C. Linderman, Hiram G. Bezerra, Yusuke Fujino, Marco A. Costa, David L. Wilson, Andrew M. Rollins |
IEEE Trans. Medical Imaging | 8 |