Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Siao Lei

dblp:371/7676 · DBLP profile ↗
← Back
4ranked-venue papers
1as first author
4since 2021 · last 2026
0000-0003-3345-0596ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 3 · 1 first-author · 3 since 2021Graphics, computer vision, multimedia, augmented reality and games · 1 · 1 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%
Computer graphics and multimedia
1 paper
Image and video processing · 100%

Topics — the 2 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics › medical imaging › molecular imaging
magnetic particle imaging
0.912025
U-N2C: A Dual Memory-Guided Disentanglement Framework for Unsupervised System Matrix Denoising in Magnetic Particle Imaging · IEEE Trans. Image Process. 2025
Image and video processing › image restoration
image denoising
0.912025
U-N2C: A Dual Memory-Guided Disentanglement Framework for Unsupervised System Matrix Denoising in Magnetic Particle Imaging · IEEE Trans. Image Process. 2025

Methods — techniques the papers use, named apart from their topics

unsupervised denoising · 1.7memory-guided disentanglement · 1.7frequency index embedding · 1.7
YearPublicationVenuePosition
2026 Multimodal structure-guided diffusion model for Magnetic Particle Imaging reconstruction
Gen Shi, Wenxuan Zou, Siao Lei, Zining Liu, Jie Tian 0001
Medical Image Anal.4
2026 Phase-Lag-Based MPS/MPI Dual-Mode Precise In Vivo Temperature Imaging Technique
abstract
Magnetic Particle Imaging (MPI) enables noninvasive temperature imaging without depth limitations. However, due to the lack of effective calibration strategies that can simultaneously address issues such as calibration infeasibility and environmental mismatch, its practical in vivo application remains challenging. In this work, we propose a novel in vivo temperature imaging method based on a dual-mode magnetic particle spectroscopy/magnetic particle imaging (MPS/MPI) system. First, MPS is employed to capture the differences in harmonic phase responses of magnetic nanoparticles (MNPs) under in vivo and in vitro conditions, thereby enabling the construction of calibration functions that are consistent with the in vivo environment. Second, an MLP based calibration strategy is proposed, which accounts for non-ideal deviations from the approximately linear temperature-phase relationship and integrates multi-parameter information into a unified network, thereby enabling accurate and stable temperature mapping. Comprehensive simulation, in vitro, and in vivo experiments demonstrate that, compared with conventional phantom-based temperature mapping methods, the proposed method reduces the in vivo temperature reconstruction error by approximately 17.24% and achieves an average absolute temperature error below $1.257~^{\circ } $ C. These results verify the feasibility of accurate in vivo temperature imaging using MPI and provide essential technical support for temperature-sensitive applications, including magnetic hyperthermia.
Siao Lei, Wenxuan Zou, Yanjun Liu 0006, Guanghui Li 0006, Gen Shi, Guangxing Zhou, Yang Jing, Jie Tian 0001
IEEE Trans. Medical Imaging1
2025 U-N2C: A Dual Memory-Guided Disentanglement Framework for Unsupervised System Matrix Denoising in Magnetic Particle Imaging
abstract
Recently, Magnetic Particle Imaging, an emerging functional imaging modality, has exhibited outstanding spatial-temporal resolution and sensitivity. The general reconstruction pipeline of Magnetic Particle Imaging involves calibrating a System Matrix and then solving an ill-posed inverse problem combined with the measured particle signals. However, the introduction of noise during the System Matrix calibration procedure is inevitable, which degrades the detailed information in the reconstructed images. Therefore, frequency selection methods based on signal-to-noise ratio are commonly adopted. However, these methods lead to a decrease in the available high-frequency components, which damages the spatial resolution. To address this problem, we propose an unsupervised memory-guided denoising framework with unpaired noisy-clean System Matrix components, called U-N2C. Specifically, we design a Pattern Memory Block to memorize System Matrix patterns, directed by a position-aware frequency index embedding. Meanwhile, we devise a Noise Memory Block to implicitly approximate noise distributions. With the guidance of our dual memory blocks, we can disentangle the noise and content of the System Matrix in the latent space. Furthermore, benefiting from the ability to model complex noise, our method can generate pseudo but high-quality noisy-clean pairs and further enhance our denoising capability. Experiments on both synthetic and real noise demonstrate that our U-N2C achieves cutting-edge performance compared to other methods. Moreover, we conduct extensive qualitative and quantitative ablation studies to verify the effectiveness of our method. Our code has been available at U-N2C.
Wenxuan Zou, Gen Shi, Siao Lei, Guanghui Li 0006, Guangxing Zhou, Yang Jing, Zhenchao Tang, Jie Tian 0001
IEEE Trans. Image Process.3
2024 Sequential Scan-Based Single-Dimension Multi-Voxel System Matrix Calibration for Open-Sided Magnetic Particle Imaging
abstract
Open-sided magnetic particle imaging (OS-MPI) has garnered significant interest due to its potential for interventional applications. However, the system matrix calibration in OS-MPI using sequential scans is a time-consuming task and susceptible to the low signal-to-noise ratio (SNR) resulting from the small calibration sample size. These challenges have hindered the practical implementation of system matrix-based reconstruction for sequentially scanned OS-MPI. To address these issues, we propose a novel calibration method, named sequen- tial scan-based single-dimension multi-voxel calibration (SS-SDMVC), to efficiently obtain a high-SNR system matrix. This method was implemented in a cylindrical field of view (FOV), where a bar calibration sample parallel to the field-free line (FFL) was shifted along a fixed radial direction. A standard image reconstruction process was also introduced to verify the feasibility of SS-SDMVC. Through simulations, we analyzed the effects of noise levels and scanner imperfections on the SS-SDMVC-based reconstruction and demonstrated its robustness. In experiments, we compared the imaging performance of SS-SDMVC and the sequential scan-based traditional cubic-FOV SMC. The results showed that SS-SDMVC reduced the number of measurements by a factor of 210.94 and achieved higher reconstruction quality. Therefore, SS-SDMVC is expected to improve the reconstruction quality of human- scale or high-gradient FFL MPI scanners.
Haoran Zhang 0007, Guanghui Li 0006, Siao Lei, Zhumei Qian, Jie Tian 0001
IEEE Trans. Medical Imaging5