Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Philip Walter Mewes

dblp:39/1065 · also Philip W. Mewes · DBLP profile ↗
← Back
8ranked-venue papers
2as first author
0since 2021 · last 2018
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 4 · 1 first-authorGraphics, computer vision, multimedia, augmented reality and games · 4 · 1 first-authorApplied, interdisciplinary, general and emerging computing · 4 · 1 first-authorSystems, architecture and hardware · 3 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
3 papers
Reinforcement learning · 32% 3D vision · 32% Robot manipulation · 26%
Interdisciplinary, comprehensive, and emerging computing
2 papers
Medical and health informatics · 100%

Topics — the 9 heaviest of 11, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Computer vision › 3D vision › image registration
medical image registration
0.312018
Dilated FCN for Multi-Agent 2D/3D Medical Image Registration · AAAI 2018
Machine learning › Reinforcement learning
multi-agent reinforcement learning
0.312018
Dilated FCN for Multi-Agent 2D/3D Medical Image Registration · AAAI 2018
Medical and health informatics › medical image registration
2d/3d registration
0.312018
Dilated FCN for Multi-Agent 2D/3D Medical Image Registration · AAAI 2018
Medical and health informatics
medical image registration
0.312018
Dilated FCN for Multi-Agent 2D/3D Medical Image Registration · AAAI 2018
Robotics › Robot manipulation
medical robotics
0.222008
Integrated system for robot-assisted in prostate biopsy in closed MRI scanner · ICRA 2008
Pneumatically operated MRI-compatible needle placement robot for prostate interventions · ICRA 2008
Robotics › Robot manipulation › medical robotics
robotic biopsy
0.112008
Integrated system for robot-assisted in prostate biopsy in closed MRI scanner · ICRA 2008
Medical and health informatics
image-guided intervention
0.112008
Pneumatically operated MRI-compatible needle placement robot for prostate interventions · ICRA 2008
Robotics › Robot manipulation › actuator design
pneumatic actuation
0.012008
Pneumatically operated MRI-compatible needle placement robot for prostate interventions · ICRA 2008
Robotics › Motion planning and robot control
robot control
0.012008
Pneumatically operated MRI-compatible needle placement robot for prostate interventions · ICRA 2008

Methods — techniques the papers use, named apart from their topics

markov decision process · 0.7dilated fully convolutional network · 0.7attention mechanism · 0.7transperineal needle insertion · 0.2pneumatic actuation · 0.2magnetic resonance imaging · 0.2intra-operative MRI · 0.2
YearPublicationVenuePosition
2018 Dilated FCN for Multi-Agent 2D/3D Medical Image Registration
abstract
2D/3D image registration to align a 3D volume and 2D X-ray images is a challenging problem due to its ill-posed nature and various artifacts presented in 2D X-ray images. In this paper, we propose a multi-agent system with an auto attention mechanism for robust and efficient 2D/3D image registration. Specifically, an individual agent is trained with dilated Fully Convolutional Network (FCN) to perform registration in a Markov Decision Process (MDP) by observing a local region, and the final action is then taken based on the proposals from multiple agents and weighted by their corresponding confidence levels. The contributions of this paper are threefold. First, we formulate 2D/3D registration as a MDP with observations, actions, and rewards properly defined with respect to X-ray imaging systems. Second, to handle various artifacts in 2D X-ray images, multiple local agents are employed efficiently via FCN-based structures, and an auto attention mechanism is proposed to favor the proposals from regions with more reliable visual cues. Third, a dilated FCN-based training mechanism is proposed to significantly reduce the Degree of Freedom in the simulation of registration environment, and drastically improve training efficiency by an order of magnitude compared to standard CNN-based training method. We demonstrate that the proposed method achieves high robustness on both spine cone beam Computed Tomography data with a low signal-to-noise ratio and data from minimally invasive spine surgery where severe image artifacts and occlusions are presented due to metal screws and guide wires, outperforming other state-of-the-art methods (single agent-based and optimization-based) by a large margin.
Shun Miao, Sebastien Piat, Peter Fischer 0001, Ahmet Tuysuzoglu, Philip Walter Mewes, Tommaso Mansi, Rui Liao
AAAI5
2016 Cryo-Balloon Catheter Localization Based on a Support-Vector-Machine Approach
abstract
Cryo-balloon catheters have attracted an increasing amount of interest in the medical community as they can reduce patient risk during left atrial pulmonary vein ablation procedures. As cryo-balloon catheters are not equipped with electrodes, they cannot be localized automatically by electro-anatomical mapping systems. As a consequence, X-ray fluoroscopy has remained an important means for guidance during the procedure. Most recently, image guidance methods for fluoroscopy-based procedures have been proposed, but they provide only limited support for cryo-balloon catheters and require significant user interaction. To improve this situation, we propose a novel method for automatic cryo-balloon catheter detection in fluoroscopic images by detecting the cryo-balloon catheter's built-in X-ray marker. Our approach is based on a blob detection algorithm to find possible X-ray marker candidates. Several of these candidates are then excluded using prior knowledge. For the remaining candidates, several catheter specific features are introduced. They are processed using a machine learning approach to arrive at the final X-ray marker position. Our method was evaluated on 75 biplane fluoroscopy images from 40 patients, from two sites, acquired with a biplane angiography system. The method yielded a success rate of 99.0% in plane A and 90.6% in plane B, respectively. The detection achieved an accuracy of 1.00 mm±0.82 mm in plane A and 1.13 mm±0.24 mm in plane B. The localization in 3-D was associated with an average error of 0.36 mm±0.86 mm.
Tanja Kurzendorfer, Philip Walter Mewes, Andreas K. Maier, Norbert Strobel, Alexander Brost
IEEE Trans. Medical Imaging2
2015 Registration of a robotic system to a medical imaging system
abstract
The presence of robots not only in industrial settings but also in operating rooms is increasing with advancements in technology. They are not only huge machines carrying out tedious and arduous tasks while being caged behind fences, but also work in collaboration, close proximity of, and in cooperation with humans. Image guided minimally invasive approaches to accurately navigate a robot to precise anatomical locations can be followed only once the robot is registered to the medical imaging system. In this paper, we present an approach to register a robotic system to a medical imaging system without the use of any tracking device or continuous X-ray imaging. The system consists of a lightweight robot equipped with internal torque sensors. The registration is realized by a series of landmark transformations. The robot is manually moved and guided to distinct landmarks whose positions are known in the coordinate system of the imaging system. By driving the robot to these distinct landmarks, their position relative to the coordinate system of the robotic system is also known. By comparing the respective positions of the landmarks in the two coordinate systems, both systems are registered. With 8 screws on the operating table used as landmarks for this registration, we obtain a median error of [6.9, 20.6, 18.6] mm and a standard deviation of [2.9, 2.6, 2.2] mm when compared to an X-ray based ground truth.
Abhinav Gulhar, Danilo Briese, Philip Walter Mewes, Georg Rose
IROS3
2014 An Augmented Reality Framework for Soft Tissue Surgery
Peter Mountney, Johannes Fallert, Stéphane Nicolau, Luc Soler, Philip Walter Mewes
MICCAI (1)5
2013 Biomechanically Driven Registration of Pre- to Intra-Operative 3D Images for Laparoscopic Surgery
Ozan Oktay, Li Zhang 0024, Tommaso Mansi, Peter Mountney, Philip Walter Mewes, Stéphane Nicolau, Luc Soler, Christophe Chefd'Hotel
MICCAI (2)5
2011 Automatic Region-of-Interest Segmentation and Pathology Detection in Magnetically Guided Capsule Endoscopy
Philip Walter Mewes, Dominik Neumann, Oleg Licegevic, Johannes Simon, Aleksandar Lj. Juloski, Elli Angelopoulou
MICCAI (3)1
2008 Pneumatically operated MRI-compatible needle placement robot for prostate interventions
abstract
Magnetic Resonance Imaging (MRI) has potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. The strong magnetic field prevents the use of conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intra-prostatic needle placement inside closed high-field MRI scanners. The robot performs needle insertion under real-time 3T MR image guidance; workspace requirements, MR compatibility, and workflow have been evaluated on phantoms. The paper explains the robot mechanism and controller design and presents results of preliminary evaluation of the system.
Gregory S. Fischer, Iulian Iordachita, Csaba Csoma, Junichi Tokuda, Philip Walter Mewes, Clare M. Tempany, Nobuhiko Hata, Gabor Fichtinger
ICRA5
2008 Integrated system for robot-assisted in prostate biopsy in closed MRI scanner
abstract
Prostate cancer biopsy is a routine medical procedure, yet conventional techniques suffer from low sensitivity attributed to suboptimal image guidance and needle placement. Targeting small lesions and foci (5 mm in diameter) is particularly prone to errors. We developed an integrated system to perform robot-assisted transperineal needle insertions into the prostate, under Magnetic Resonance Imaging (MRI) guidance. The system provides arbitrary needle trajectories and allows for simultaneous surveillance and correction of the needle path, based on intra-operative MRI. System functionality and data transfer and processing tests were conducted. Five lesions embedded in the gel phantom were targeted successfully, while communication delays (due to higher image frame rates) had no adverse affect on robot-software communication. The system was sufficiently resistant to high network loads and performed with an acceptable transfer rate.
Philip Walter Mewes, Junichi Tokuda, Simon P. DiMaio, Gregory S. Fischer, Csaba Csoma, David G. Gobbi, Clare M. Tempany, Gabor Fichtinger, Nobuhiko Hata
ICRA1