Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Dennis L. Parker

dblp:40/4657 · DBLP profile ↗
← Back
9ranked-venue papers
0as first author
1since 2021 · last 2024
0000-0003-2557-8952ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 7 · 1 since 2021Graphics, computer vision, multimedia, augmented reality and games · 2 · 1 since 2021Systems, architecture and hardware · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer graphics and multimedia
1 paper
Image and video processing · 50% Visualization and visual analytics · 50%

Topics — the 2 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Visualization and visual analytics › volume visualization
maximum intensity projection
0.012001
Small vessel enhancement in MRA images using local maximum mean processing · IEEE Trans. Image Process. 2001
Image and video processing › biomedical image analysis
medical image analysis
0.012001
Small vessel enhancement in MRA images using local maximum mean processing · IEEE Trans. Image Process. 2001

Methods — techniques the papers use, named apart from their topics

weight function combination · 0.0maximum intensity projection · 0.0local maximum mean · 0.0
YearPublicationVenuePosition
2024 Physics Informed Neural Networks for Estimation of Tissue Properties from Multi-echo Configuration State MRI
Samuel I. Adams-Tew, Henrik Odéen, Dennis L. Parker, Cheng-Chieh Cheng, Bruno Madore, Allison Payne, Sarang C. Joshi
MICCAI (11)3
2011 Validation of an arterial tortuosity measure with application to hypertension collection of clinical hypertensive patients
abstract
BACKGROUND: Hypertension may increase tortuosity or twistedness of arteries. We applied a centerline extraction algorithm and tortuosity metric to magnetic resonance angiography (MRA) brain images to quantitatively measure the tortuosity of arterial vessel centerlines. The most commonly used arterial tortuosity measure is the distance factor metric (DFM). This study tested a DFM based measurement's ability to detect increases in arterial tortuosity of hypertensives using existing images. Existing images presented challenges such as different resolutions which may affect the tortuosity measurement, different depths of the area imaged, and different artifacts of imaging that require filtering. METHODS: The stability and accuracy of alternative centerline algorithms was validated in numerically generated models and test brain MRA data. Existing images were gathered from previous studies and clinical medical systems by manually reading electronic medical records to identify hypertensives and negatives. Images of different resolutions were interpolated to similar resolutions. Arterial tortuosity in MRA images was measured from a DFM curve and tested on numerically generated models as well as MRA images from two hypertensive and three negative control populations. Comparisons were made between different resolutions, different filters, hypertensives versus negatives, and different negative controls. RESULTS: In tests using numerical models of a simple helix, the measured tortuosity increased as expected with more tightly coiled helices. Interpolation reduced resolution-dependent differences in measured tortuosity. The Korean hypertensive population had significantly higher arterial tortuosity than its corresponding negative control population across multiple arteries. In addition one negative control population of different ethnicity had significantly less arterial tortuosity than the other two. CONCLUSIONS: Tortuosity can be compared between images of different resolutions by interpolating from lower to higher resolutions. Use of a universal negative control was not possible in this study. The method described here detected elevated arterial tortuosity in a hypertensive population compared to the negative control population and can be used to study this relation in other populations.
Karl T. Diedrich, John A. Roberts, Richard H. Schmidt, Chang-Ki Kang, Zang-Hee Cho, Dennis L. Parker
BMC Bioinform.6
2005 3D multi-scale vessel enhancement filtering based on curvature measurements: application to time-of-flight MRA
Brian E. Chapman, Dennis L. Parker
Medical Image Anal.2
2004 Diagnostic fidelity of the Z-buffer segmentation algorithm: preliminary assessment based on intracranial aneurysm detection
Brian E. Chapman, Dennis L. Parker, Janet O. Stapelton, Jay S. Tsuruda, Claudia Mello-Thoms, Bronwin Hamilton, Gregory L. Katzman
J. Biomed. Informatics2
2004 Intracranial vessel segmentation from time-of-flight MRA using pre-processing of the MIP Z-buffer: accuracy of the ZBS algorithm
Brian E. Chapman, Janet O. Stapelton, Dennis L. Parker
Medical Image Anal.3
2001 Small vessel enhancement in MRA images using local maximum mean processing
abstract
The enhancement of small vessels in MRA imaging is an important problem. In this paper, we propose using local maximum mean (LMM) processing to enhance the detectability of small vessels. At each voxel in the original three-dimensional (3-D) data set, the LMM over the line segments in the cube centered at the voxel is taken and used to form the 3-D LMM data set. The maximum intensity projection (MIP) is then applied to the LMM data to produce the two-dimensional (2-D) LMM-MIP image. Through LMM processing, the variance of background tissue is reduced, thus increasing the detectability of small vessels. Moreover, the single bright voxels are suppressed and the disconnected small vessels can be connected. However, the LMM processing widens the larger, brighter vessels. To keep the advantages provided by both the LMM-MIP and MIP images, it is proposed that weight functions be used to combine them. The performance of the LMM-MIP algorithm is analyzed and compared with the performance of the MIP algorithm under three measures: The vessel voxel projection probability, the vessel receiver operating characteristic (ROC) curve and the vessel-tissue contrast-to-noise ratio (CNR). Closed forms of the three measures are obtained. It is shown that the LMM-MIP algorithm improves the detectability of small vessels under all three measures. The longer the projection path and the larger the CNR of the original data, then the greater the improvement. Confirming the theoretical analysis, results of an experiment utilizing practical MRA data demonstrate the improved visual quality of small vessels.
Dennis L. Parker
IEEE Trans. Image Process.2
1999 Evaluation of Measures of Technical Image Quality for Intracranial Magnetic Resonance Angiography
Brian E. Chapman, K. Craig Goodrich, Andrew L. Alexander, Duane D. Blatter, Dennis L. Parker
Comput. Biomed. Res.5
1999 Performance Analysis of Maximum Intensity Projection Algorithm for Display of MRA Images
abstract
The maximum intensity projection (MIP) is a popularly used algorithm for display of MRA images, but its performance has not been rigorously analyzed before. In this paper, four measures are proposed for the performance of the MIP algorithm and the quality of images projected from three-dimensional (3-D) data, which are vessel voxel projection probability, vessel detection probability, false vessel probability, and vessel-tissue contrast-to-noise ratio (CNR). As side products, vessel-missing probability, vessel receiver operating characteristics (ROC's), and mean number of false vessels are also studied. Based on the assumptions that the intensities of vessel, tissue, and noise along a projection path are independent Gaussian, these measures are derived and obtained all in closed forms. All the measures are functions of explicit parameters: vessel-to-tissue noise ratio (VTNR) and CNR of 3-D data prior to the MIP, vessel diameter, and projection length. It is shown that the MIP algorithm increases the CNR of large vessels whose CNR prior to the MIP is high and whose diameters are large. The increase in CNR increases with projection path length. On the other hand, all the proposed measures indicate that the small vessels that have low CNR prior to the MIP and small diameters suffer from the MIP. The performance gets worse as projection path length increases. All measures demonstrate a better performance when the vessel diameter is larger. Other properties and possible applications of the derived measures are also discussed.
Dennis L. Parker
IEEE Trans. Medical Imaging2
1991 Granularity Analysis for Parallel 3D Coronary Arteriography
Alok Sarwal, Sin Guan Tan, Füsun Özgüner, Dennis L. Parker
ICPP (3)4