Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Nikolai Hungr

dblp:42/7413 · DBLP profile ↗
← Back
3ranked-venue papers
3as first author
0since 2021 · last 2016
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 3 · 3 first-authorGraphics, computer vision, multimedia, augmented reality and games · 1 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
2 papers
Robot manipulation · 83% 3D vision · 17%

Topics — the 4 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation
medical robotics
0.422016
Design and Validation of a CT- and MRI-Guided Robot for Percutaneous Needle Procedures · IEEE Trans. Robotics 2016
A 3-D Ultrasound Robotic Prostate Brachytherapy System With Prostate Motion Tracking · IEEE Trans. Robotics 2012
Robotics › Robot manipulation › robot design
robot design and kinematics
0.212016
Design and Validation of a CT- and MRI-Guided Robot for Percutaneous Needle Procedures · IEEE Trans. Robotics 2016
Computer vision › 3D vision › image registration
medical image registration
0.112012
A 3-D Ultrasound Robotic Prostate Brachytherapy System With Prostate Motion Tracking · IEEE Trans. Robotics 2012
Robotics › Robot manipulation › medical robotics
needle insertion
0.012012
A 3-D Ultrasound Robotic Prostate Brachytherapy System With Prostate Motion Tracking · IEEE Trans. Robotics 2012

Methods — techniques the papers use, named apart from their topics

registration · 0.2MRI imaging · 0.2CT imaging · 0.2prostate motion tracking · 0.13-d ultrasound · 0.1
YearPublicationVenuePosition
2016 Design and Validation of a CT- and MRI-Guided Robot for Percutaneous Needle Procedures
abstract
This paper describes the design and evaluation of the second generation of a robotic system called the light puncture robot for thoracic and abdominopelvic interventional radiology procedures under CT and MRI guidance. It is mounted on the patient's body and positions and inserts the needle according to the trajectory and target chosen by the radiologist in the image. The mechanical design is described in detail along with its forward and inverse kinematics. The robot can be segmented and registered fully automatically in both imaging modalities. Phantom experiments in the CT scanner and preliminary feasibility experiments in the MRI are described, showing a targeting accuracy of 3.3 ± 1.7 mm in gelatin for depths ranging from 30 to 90 mm and needle orientations of -13° to +15° about normal from the patient's skin. A detailed error analysis is discussed along with potential improvements in the system. The potential clinical advantages of the system include higher targeting accuracy for complex dual obliquity trajectories, the need for fewer images, and improved accessibility to MRI-guided interventions.
Nikolai Hungr, Ivan Bricault, Philippe Cinquin, Céline Fouard
IEEE Trans. Robotics1
2012 A 3-D Ultrasound Robotic Prostate Brachytherapy System With Prostate Motion Tracking
abstract
This paper describes a new 3-D ultrasound robotic prostate brachytherapy system. It uses a stationary 3-D ultrasound probe rigidly fixed to a robotic needle insertion mechanism. The novelty of the system is its ability to track prostate motion intraoperatively to allow the dose planning and needle trajectories or depths to be adapted to take into account these motions. Prostate tracking is done using a fast 3-D ultrasound registration algorithm previously validated for biopsy guidance. The 7-degree-of-freedom (7-DOF) robot and ultrasound probe are calibrated together with an accuracy of 0.9 mm, allowing the needles to be precisely inserted to the seed targets chosen in the reference ultrasound image. Experiments were conducted on mobile, deformable synthetic prostate phantoms using a prototype laboratory system. Results showed that, with prostate motions of up to 7 mm, the system was able to reach the chosen targets with less than 2-mm accuracy in the needle insertion direction. This measured accuracy included extrinsic measurement errors of up to 1.1 mm. A preliminary cadaver feasibility study was also described in preparation for more realistic experimentation of the system.
Nikolai Hungr, Michael Baumann 0001, Jean-Alexandre Long, Jocelyne Troccaz
IEEE Trans. Robotics1
2011 Interventional Radiology Robot for CT and MRI Guided Percutaneous Interventions
Nikolai Hungr, Céline Fouard, Adeline Robert, Ivan Bricault, Philippe Cinquin
MICCAI (1)1