Demo Data from SIGIR 2026 / reviewers in the wild / expert
Yang Yang 0103
dblp:48/450-103
· DBLP profile ↗
2ranked-venue papers
0as first author
0since 2021 · last 2020
0000-0002-2371-0377ORCID · conflict
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 2Systems, architecture and hardware · 1Human-computer interaction and ubiquitous computing · 1Applied, interdisciplinary, general and emerging computing · 1
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
1 paper |
Motion planning and robot control · 67% Robot manipulation · 33% | |
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% |
Topics — the 4 heaviest of 4, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Motion planning and robot control › manipulator control
force-constrained control |
0.4 | 1 | 2020 | Towards Bimanual Vein Cannulation: Preliminary Study of a Bimanual Robotic System With a Dual Force Constraint Controller · ICRA 2020 |
Robotics › Motion planning and robot control
robot control |
0.4 | 1 | 2020 | Towards Bimanual Vein Cannulation: Preliminary Study of a Bimanual Robotic System With a Dual Force Constraint Controller · ICRA 2020 |
Robotics › Robot manipulation › medical robotics › surgical robotics
teleoperated surgical robot |
0.4 | 1 | 2020 | Towards Bimanual Vein Cannulation: Preliminary Study of a Bimanual Robotic System With a Dual Force Constraint Controller · ICRA 2020 |
Medical and health informatics › surgical robotics
robot-assisted surgery |
0.1 | 1 | 2020 | Towards Bimanual Vein Cannulation: Preliminary Study of a Bimanual Robotic System With a Dual Force Constraint Controller · ICRA 2020 |
Methods — techniques the papers use, named apart from their topics
force sensing · 0.9dual force constraint controller · 0.9
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2020 | Towards Bimanual Vein Cannulation: Preliminary Study of a Bimanual Robotic System With a Dual Force Constraint ControllerabstractRetinal vein cannulation is a promising approach for treating retinal vein occlusion that involves injecting medicine into the occluded vessel to dissolve the clot. The approach remains largely unexploited clinically due to surgeon limitations in detecting interaction forces between surgical tools and retinal tissue. In this paper, a dual force constraint controller for robot-assisted retinal surgery was presented to keep the tool-to-vessel forces and tool-to-sclera forces below prescribed thresholds. A cannulation tool and forceps with dual force-sensing capability were developed and used to measure force information fed into the robot controller, which was implemented on existing Steady Hand Eye Robot platforms. The robotic system facilitates retinal vein cannulation by allowing a user to grasp the target vessel with the forceps and then enter the vessel with the cannula. The system was evaluated on an eye phantom. The results showed that, while the eyeball was subjected to rotational disturbances, the proposed controller actuates the robotic manipulators to maintain the average tool-to-vessel force at 10.9 mN and 13.1 mN and the average tool-to-sclera force at 38.1 mN and 41.2 mN for the cannula and the forcpes, respectively. Such small tool-to-tissue forces are acceptable to avoid retinal tissue injury. Additionally, two clinicians participated in a preliminary user study of the bimanual cannulation demonstrating that the operation time and tool-to-tissue forces are significantly decreased when using the bimanual robotic system as compared to freehand performance. Changyan He, Emily Yang, Müller G. Urias, Yang Yang 0103, Peter Gehlbach, Iulian Iordachita |
ICRA | 5 |
| 2018 | User Behavior Evaluation in Robot-Assisted Retinal SurgeryabstractRetinal microsurgery is technically demanding and requires high surgical skill with very little room for manipulation error. The introduction of robotic assistance has the potential to enhance and expand a surgeon's manipulation capabilities during retinal surgery, i.e., improve precision, cancel physiological hand tremor, and provide sensing information. However, surgeon performance may also be negatively impacted by robotic assistance due to robot structural stiffness and nonintuitive controls. In complying with robotic constraints, the surgeon loses the dexterity of the human hand. In this paper, we present a preliminary experimental study to evaluate user behavior when affected by robotic assistance during mock retinal surgery. In these experiments user behavior is characterized by measuring the forces applied by the user to the sclera, the tool insertion/retraction speed, the tool insertion depth relative to the scleral entry point, and the duration of surgery. The users' behavior data is collected during three mock retinal surgery tasks with four users. Each task is conducted using both freehand and robot-assisted techniques. The univariate user behavior and the correlations of multiple parameters of user behavior are analyzed. The results show that robot assistance prolongs the duration of the surgery and increases the manipulation forces applied to sclera, but refines the insertion velocity and eliminates hand tremor. Changyan He, Marina Roizenblatt, Niravkumar A. Patel, Yang Yang 0103, Peter Gehlbach, Iulian Iordachita |
RO-MAN | 5 |