Demo Data from SIGIR 2026 / reviewers in the wild / expert
Miles N. Wernick
dblp:66/5230
· DBLP profile ↗
55ranked-venue papers
1as first author
4since 2021 · last 2022
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Graphics, computer vision, multimedia, augmented reality and games · 40 · 4 since 2021Applied, interdisciplinary, general and emerging computing · 14 · 1 first-authorArtificial intelligence and machine learning · 1
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Computer graphics and multimedia
2 papers |
Image and video processing · 62% Geometric modeling and processing · 30% Multimedia analysis and retrieval · 8% | |
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% |
Topics — the 8 heaviest of 8, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Medical and health informatics
medical imaging |
0.1 | 1 | 2010 | Prostate Cancer Localization With Multispectral MRI Using Cost-Sensitive Support Vector Machines and Conditional Random Fields · IEEE Trans. Image Process. 2010 |
Image and video processing › image segmentation
conditional random field |
0.1 | 1 | 2010 | Prostate Cancer Localization With Multispectral MRI Using Cost-Sensitive Support Vector Machines and Conditional Random Fields · IEEE Trans. Image Process. 2010 |
Image and video processing
image segmentation |
0.1 | 1 | 2010 | Prostate Cancer Localization With Multispectral MRI Using Cost-Sensitive Support Vector Machines and Conditional Random Fields · IEEE Trans. Image Process. 2010 |
Geometric modeling and processing › mesh processing › mesh adaptation
content-adaptive mesh generation |
0.0 | 1 | 2003 | A fast approach for accurate content-adaptive mesh generation · IEEE Trans. Image Process. 2003 |
Image and video processing
image representation |
0.0 | 1 | 2003 | A fast approach for accurate content-adaptive mesh generation · IEEE Trans. Image Process. 2003 |
Geometric modeling and processing
mesh generation |
0.0 | 1 | 2003 | A fast approach for accurate content-adaptive mesh generation · IEEE Trans. Image Process. 2003 |
Geometric modeling and processing › shape representation
mesh representation |
0.0 | 1 | 2003 | A fast approach for accurate content-adaptive mesh generation · IEEE Trans. Image Process. 2003 |
Multimedia analysis and retrieval
image classification |
0.0 | 1 | 2010 | Prostate Cancer Localization With Multispectral MRI Using Cost-Sensitive Support Vector Machines and Conditional Random Fields · IEEE Trans. Image Process. 2010 |
Methods — techniques the papers use, named apart from their topics
cost-sensitive SVM · 0.2conditional random field · 0.2floyd-steinberg error diffusion · 0.0delaunay triangulation · 0.0
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2022 | Dose-Blind Denoising With Deep Learning in Cardiac SpectabstractDeep learning denoising methods have been found to be effective for noise suppression in reduced-dose studies in medical imaging applications. In this work, we investigate the feasibility of improving the generalizability of a denoising network by using a dose-blind training approach, in which the network is trained with a loss function defined to accommodate the varying data statistics associated with multiple reduced-dose levels. In the experiments, we demonstrated this approach on quarter- and eighth-dose data from a set of 895 clinical cardiac SPECT perfusion imaging acquisitions. The quantitative results show that a dose-blind denoising network could generalize well over both dose levels, and outperformed dose-specific training in detection of perfusion defects at both quarter- and eighth-dose data (p-values-4; paired t-test). Junchi Liu, Yongyi Yang, Miles N. Wernick, P. Hendrik Pretorius, Michael A. King |
ICIP | 3 |
| 2022 | A Study of Deep Learning Networks for Motion Compensation in Cardiac Gated Spect ImagesabstractMotion compensation is an effective approach for noise suppression and motion blur reduction in cardiac gated SPECT imaging. In this work, we investigate the potential benefit of using a deep learning network for motion compensation in a sequence of gated images throughout the cardiac cycle in the presence of large inter-subject variability and imaging degrading factors. We make use a set of clinical acquisitions from 130 subjects and quantify the motion compensation accuracy by variants of two known cascaded learning networks (namely VTN and VoxelMorph). The results in the experiments show that both networks can yield accurate compensation results in both standard dose and half dose studies. Specifically, VTN achieved a relative MSE of 0.0312 (full dose) and 0.0561 (half dose), compared to 0.0340 (full dose) and 0.0356 (half dose) for VoxelMorph. Both networks also outperformed the classical optical flow equation (OFE) method. Xirang Zhang, Álvaro Belloso, Yongyi Yang, Miles N. Wernick, P. Hendrik Pretorius, Michael A. King |
ICIP | 4 |
| 2021 | A Regularized Approach For Respiratory Motion Estimation From Short-Time Projection Data Frames In Emission TomographyabstractCardiac SPECT perfusion imaging is important for diagnosis and evaluation of coronary artery diseases. However, the acquired image data can suffer from motion blur due to patient respiratory motion. We propose a maximum-likelihood estimation (MLE) approach to determine a surrogate respiratory signal from short-time acquisition frames for motion correction. To compensate for the low data counts in the short-time frames, we employ a regularization term to exploit the similarity in acquired data among neighboring acquisition angles. In the experiments we validated this approach first on a set of simulated phantom data with known respiratory motion, and then on clinical acquisitions from 17 subjects. The results demonstrate that the proposed MLE approach could yield a reliable respiratory motion signal even with the acquisition frame duration being as short as 100ms, and outperformed both center-of-mass and Laplacian eigen-maps methods. Andoni I. Garmendia, Yongyi Yang, Miles N. Wernick, P. Hendrik Pretorius, Michael A. King |
ICIP | 4 |
| 2021 | Accounting For Inter-Subject Variations in Deep Learning for Reduced-Dose Studies in Cardiac SPECTabstractDeep learning (DL) denoising has recently found applications in a wide range of important problems in medical imaging. A practical challenge encountered in clinical applications is that the acquired image data can exhibit great variability in terms of noise level among different subjects. In this study, we investigate whether it can be beneficial to exploit the varying data statistics among different subjects in a DL denoising network. We propose a modified loss function in the form of a weighted sum of mean-squared-errors for DL training in which the contribution from individual subjects is adjusted according to their noise levels. In the experiments we demonstrated this approach with a set of 895 clinical acquisitions in cardiac SPECT studies with 50% of standard dose. The quantitative results show that the proposed approach can further improve both the regional accuracy of the reconstructed left ventricle and the detection accuracy of perfusion defects. Junchi Liu, Yongyi Yang, Miles N. Wernick, P. Hendrik Pretorius, Michael A. King |
ICIP | 3 |
| 2020 | Improving Diagnostic Accuracy in Low-Dose SPECT Myocardial Perfusion Imaging With Convolutional Denoising NetworksabstractLowering the administered dose in SPECT myocardial perfusion imaging (MPI) has become an important clinical problem. In this study we investigate the potential benefit of applying a deep learning (DL) approach for suppressing the elevated imaging noise in low-dose SPECT-MPI studies. We adopt a supervised learning approach to train a neural network by using image pairs obtained from full-dose (target) and low-dose (input) acquisitions of the same patients. In the experiments, we made use of acquisitions from 1,052 subjects and demonstrated the approach for two commonly used reconstruction methods in clinical SPECT-MPI: 1) filtered backprojection (FBP), and 2) ordered-subsets expectation-maximization (OSEM) with corrections for attenuation, scatter and resolution. We evaluated the DL output for the clinical task of perfusion-defect detection at a number of successively reduced dose levels (1/2, 1/4, 1/8, 1/16 of full dose). The results indicate that the proposed DL approach can achieve substantial noise reduction and lead to improvement in the diagnostic accuracy of low-dose data. In particular, at 1/2 dose, DL yielded an area-under-the-ROC-curve (AUC) of 0.799, which is nearly identical to the AUC = 0.801 obtained by OSEM at full-dose ( p -value = 0.73); similar results were also obtained for FBP reconstruction. Moreover, even at 1/8 dose, DL achieved AUC = 0.770 for OSEM, which is above the AUC = 0.755 obtained at full-dose by FBP. These results indicate that, compared to conventional reconstruction filtering, DL denoising can allow for additional dose reduction without sacrificing the diagnostic accuracy in SPECT-MPI. Albert Juan Ramon, Yongyi Yang, P. Hendrik Pretorius, Karen L. Johnson, Michael A. King, Miles N. Wernick |
IEEE Trans. Medical Imaging | 6 |
| 2019 | Approximate 4D Reconstruction of Cardiac-Gated Spect Images Using a Residual Convolutional Neural Networkabstract4D image reconstruction can significantly improve the image quality in cardiac-gated imaging using single-photon emission computed tomography (SPECT). However, it is also associated with increased computation complexity which prevents it from being widely used in the clinic. In this study, we investigate a post-processing approach for cardiac-gated SPECT images by using a 3D residual convolutional neural network (CNN). In our formulation, the network is trained to produce images that are comparable to 4D reconstruction. In the experiments, we demonstrated this approach on a set of 197 clinical acquisitions. The results show that the proposed CNN approach can effectively suppress the noise level in the reconstructed myocardium. It also outperforms two alternative post-processing methods, including a non-local means (NLM) filter previously developed for gated SPECT images. Yongyi Yang, Miles N. Wernick, P. Hendrik Pretorius, Michael A. King |
ICIP | 3 |
| 2019 | Personalized Models for Injected Activity Levels in SPECT Myocardial Perfusion ImagingabstractWe propose a patient-specific ("personalized") approach for tailoring the injected activities to individual patients in order to achieve dose reduction in SPECT-myocardial perfusion imaging (MPI). First, we develop a strategy to determine the minimum dose levels required for each patient in a large set of clinical acquisitions (857 subjects) such that the reconstructed images are sufficiently similar to that obtained at conventional clinical dose. We then apply machine learning models to predict the required dose levels on an individual basis based on a set of patient attributes which include body measurements and various clinical variables. We demonstrate the personalized dose models for two commonly used reconstruction methods in clinical SPECT-MPI: 1) conventional filtered backprojection (FBP) with post-filtering and 2) ordered-subsets expectation-maximization (OS-EM) with corrections for attenuation, scatter and resolution, and evaluate their performance in perfusion-defect detection by using the clinical Quantitative Perfusion SPECT software package. The results indicate that the achieved dose reduction can vary greatly among individuals from their conventional clinical dose and that the personalized dose models can achieve further reduction on average compared with a global (non-patient specific) dose reduction approach. In particular, the average personalized dose level can be reduced to 58% and 54% of the full clinical dose, respectively, for FBP and OS-EM reconstruction, while without deteriorating the accuracy in perfusion-defect detection. Furthermore, with the average personalized dose further reduced to only 16% of full dose, OS-EM can still achieve a detection accuracy level comparable to that of FBP with full dose. Albert Juan Ramon, Yongyi Yang, P. Hendrik Pretorius, Karen L. Johnson, Michael A. King, Miles N. Wernick |
IEEE Trans. Medical Imaging | 6 |
| 2018 | Effect of Respiratory Motion Correction in Perfusion Spect ImagingabstractRespiratory motion is known to cause non-uniform blur in the reconstructed myocardium in cardiac perfusion imaging with single photon emission computed tomography (SPECT), which can adversely degrade the detectability of perfusion defects. To deal with this issue, we recently proposed a motion-compensated reconstruction scheme by using acquisitions with amplitude-binning. In this study, we evaluate the potential benefit of respiratory motion correction by quantifying the contrast-to-noise ratio (CNR) of the perfusion defects in the reconstructed images using clinical acquisitions. The results demonstrate that with motion correction the CNR is improved to 1.77 from 1.57 (without correction). In addition, there is also an improvement in the spatial resolution of the left ventricular wall. We also investigate the robustness of this reconstruction scheme for reduced dose imaging. Yongyi Yang, Albert Juan Ramon, Miles N. Wernick, P. Hendrik Pretorius, Michael A. King |
ICIP | 4 |
| 2017 | Reconstruction of respiratory-binned cardiac spect using a robust smoothing priorabstractCardiac images in single photon emission computed tomography (SPECT) are known to suffer from loss of resolution associated with respiratory motion. In this work, we investigate the use of a spatially adaptive smoothing prior in a motion-compensated reconstruction framework for SPECT, wherein respiratory binned data are incorporated into the reconstruction of the myocardium with respect to a reference respiratory bin. In the experiments, we evaluated this approach with both simulated imaging data and two sets of clinical acquisitions. The results show that the proposed approach can be effective for improving the heart wall in terms of both the noise level and spatial resolution. The proposed approach was also demonstrated to be robust when the imaging dose was reduced. Yongyi Yang, Miles N. Wernick, P. Hendrik Pretorius, Michael A. King |
ICIP | 3 |
| 2017 | 4-D Reconstruction With Respiratory Correction for Gated Myocardial Perfusion SPECTabstractCardiac single photon emission computed tomography (SPECT) images are known to suffer from both cardiac and respiratory motion blur. In this paper, we investigate a 4-D reconstruction approach to suppress the effect of respiratory motion in gated cardiac SPECT imaging. In this approach, the sequence of cardiac gated images is reconstructed with respect to a reference respiratory amplitude bin in the respiratory cycle. To combat the challenge of inherent high-imaging noise, we utilize the data counts acquired during the entire respiratory cycle by making use of a motion-compensated scheme, in which both cardiac motion and respiratory motion are taken into account. In the experiments, we first use Monte Carlo simulated imaging data, wherein the ground truth is known for quantitative comparison. We then demonstrate the proposed approach on eight sets of clinical acquisitions, in which the subjects exhibit different degrees of respiratory motion blur. The quantitative evaluation results show that the 4-D reconstruction with respiratory correction could effectively reduce the effect of motion blur and lead to a more accurate reconstruction of the myocardium. The mean-squared error of the myocardium is reduced by 22%, and the left ventricle (LV) resolution is improved by 21%. Such improvement is also demonstrated with the clinical acquisitions, where the motion blur is markedly improved in the reconstructed LV wall and blood pool. The proposed approach is also noted to be effective on correcting the spill-over effect in the myocardium from nearby bowel or liver activities. Wenyuan Qi, Yongyi Yang, Miles N. Wernick, P. Hendrik Pretorius, Michael A. King |
IEEE Trans. Medical Imaging | 4 |
| 2016 | Joint motion correction and image reconstruction in respiratory-gated SPECTabstractDue to the irregularity in respiratory patterns observed clinically, the acquired data in cardiac SPECT with respiratory-gating can exhibit high variability among both gate intervals and acquisition angles. Such variability can lead to differing noise characteristics among respiratory gates, which would adversely affect the accuracy of motion estimation. To address this difficulty, we develop a joint motion-estimation and image-reconstruction approach, in which the respiratory motion is estimated simultaneously along with the source distribution. In the experiments, we demonstrated this joint estimation-reconstruction approach with both quantitative simulated NCAT data and a set of clinical acquisition. We also explored its robustness with reduced imaging dose. The results show that the proposed approach can further improve the reconstructed myocardium over a pre-reconstruction motion-estimation approach. Yongyi Yang, Miles N. Wernick, P. Hendrik Pretorius, Michael A. King |
ICIP | 3 |
| 2015 | 4D non-local means post-filtering for cardiac gated SPECTabstractCardiac gated images in single photon emission computed tomography (SPECT) are known to suffer from increased noise due to low data counts. In this work, we investigate a post-filtering approach for SPECT images based on nonlocal means (NLM) filtering. In order to exploit the inherent correlation of the signal components among the different cardiac gates, we employ a spatiotemporal NLM filter, in which both space and temporal neighborhoods are taken into account in the similarity processing. In the experiments, we demonstrated this approach with both simulated NCAT imaging data and a set of clinical acquisition. The results show that the use of temporal smoothing in NLM could be much more effective for improving the quality of gated images than spatial smoothing. Yongyi Yang, Wenyuan Qi, Miles N. Wernick, P. Hendrik Pretorius, Michael A. King |
ICIP | 4 |
| 2014 | Reconstruction with angular compensation in respiratory-gated cardiac SPECTabstractIn respiratory-gated cardiac SPECT with amplitude binning, the acquisition time can vary greatly both among respiratory gates and among acquisition angles within each gate. If not properly accounted for, this uneven distribution in acquired data statistics will lead to limited-angle artifacts in reconstruction, which in turn can impact on the accuracy of respiratory motion correction. We investigate a compensation scheme for this uneven distribution by directly taking into account in the imaging model the actual acquisition time at different projection angles. In the experiment, we demonstrated this approach with simulated NCAT imaging data, for which quantitative results were obtained on both the reconstructed myocardium and estimated motion; we also tested the proposed approach on a set of clinical acquisition. The results show that the proposed approach could effectively suppress the limited-angle artifacts and improve the reconstruction in terms of both image accuracy and lesion detectability. Wenyuan Qi, Yongyi Yang, Miles N. Wernick, P. Hendrik Pretorius, Michael A. King |
ICIP | 3 |
| 2013 | 4D reconstruction for dual cardiac-respiratory gated SPECTabstractCardiac gated SPECT is an important clinical tool for assessment of both myocardial perfusion and ventricular function. Spatiotemporal (aka 4D) reconstruction has been demonstrated to be effective for suppressing the increased noise in cardiac gated SPECT. In this work, we propose a joint 4D reconstruction approach to accommodate the different respiratory phases in a dual cardiac-respiratory gating scheme in order to combat the artifacts of respiratory motion in cardiac SPECT. The proposed approach is to exploit the correlation in the signal component among both the cardiac and respiratory phases in the acquired data. In our experiments we evaluated the approach using simulated SPECT imaging with the 4D NCAT phantom and Tc-99m labeled Sestamibi as the imaging agent. Our results demonstrate that the proposed approach could effectively suppress the artifacts caused by respiratory motion in the reconstruction. Wenyuan Qi, Yongyi Yang, Miles N. Wernick, Michael A. King |
ICIP | 3 |
| 2011 | Direct reconstruction of parametric images from cardiac gated dynamic spect dataabstractIn this work, we propose a direct reconstruction approach to determine a sequence of kinetic parametric images from a single gated acquisition, of which the goal is to provide information simultaneously for both tracer kinetics and cardiac wall motion. The parameter images of the different gates are determined jointly using maximum a posteriori (MAP) estimation from all the available image data in order to exploit the similarity among the different gates. The proposed approach is demonstrated in the context of single photon emission computed tomography (SPECT), where the challenge is great due to the under-determined nature of the problem and increased imaging noise. Our results show that use of gated temporal smoothing could effectively improve the reconstruction accuracy of kinetic parameters. Xiaofeng Niu, Yongyi Yang, Miles N. Wernick |
ICIP | 3 |
| 2010 | Gated dynamic image reconstruction using temporal B-splinesabstractIn this work we develop a fully five-dimensional (5D) reconstruction approach based on B-spline modeling for cardiac gated dynamic images. The goal is to obtain a single sequence showing simultaneously both cardiac motion and kinetic tracer distribution change over time from one acquisition. The proposed approach is demonstrated in the context of single photon emission computed tomography (SPECT), where the challenge is great due to the under-determined nature of the problem and increased imaging noise. Our evaluation results demonstrate that the 5D reconstruction procedure can lead to accurate reconstruction of gated dynamic images for both cardiac motion and perfusion defect detection. Xiaofeng Niu, Yongyi Yang, Mingwu Jin, Miles N. Wernick |
ICIP | 4 |
| 2010 | Prostate Cancer Localization With Multispectral MRI Using Cost-Sensitive Support Vector Machines and Conditional Random FieldsabstractProstate cancer is a leading cause of cancer death for men in the United States. Fortunately, the survival rate for early diagnosed patients is relatively high. Therefore, in vivo imaging plays an important role for the detection and treatment of the disease. Accurate prostate cancer localization with noninvasive imaging can be used to guide biopsy, radiotherapy, and surgery as well as to monitor disease progression. Magnetic resonance imaging (MRI) performed with an endorectal coil provides higher prostate cancer localization accuracy, when compared to transrectal ultrasound (TRUS). However, in general, a single type of MRI is not sufficient for reliable tumor localization. As an alternative, multispectral MRI, i.e., the use of multiple MRI-derived datasets, has emerged as a promising noninvasive imaging technique for the localization of prostate cancer; however almost all studies are with human readers. There is a significant inter and intraobserver variability for human readers, and it is substantially difficult for humans to analyze the large dataset of multispectral MRI. To solve these problems, this study presents an automated localization method using cost-sensitive support vector machines (SVMs) and shows that this method results in improved localization accuracy than classical SVM. Additionally, we develop a new segmentation method by combining conditional random fields (CRF) with a cost-sensitive framework and show that our method further improves cost-sensitive SVM results by incorporating spatial information. We test SVM, cost-sensitive SVM, and the proposed cost-sensitive CRF on multispectral MRI datasets acquired from 21 biopsy-confirmed cancer patients. Our results show that multispectral MRI helps to increase the accuracy of prostate cancer localization when compared to single MR images; and that using advanced methods such as cost-sensitive SVM as well as the proposed cost-sensitive CRF can boost the performance significantly when compared to SVM. Yusuf Artan, Masoom A. Haider, Deanna L. Langer, Theodorus H. van der Kwast, Andrew J. Evans, Yongyi Yang, Miles N. Wernick, John Trachtenberg, Imam Samil Yetik |
IEEE Trans. Image Process. | 7 |
| 2009 | Cardiac perfusion defect detection using gated dynamic SPECT imagingabstractIn our previous work we proposed a dynamic image reconstruction procedure for gated cardiac imaging, of which the goal is to obtain a single image sequence that shows simultaneously both cardiac motion and tracer distribution change over time. In this work, we further develop and demonstrate the feasibility of this procedure for perfusion defect detection in gated cardiac imaging. We conduct Fisher's linear discriminant analysis on the reconstructed dynamic images, and derive quantitative measures to differentiate defects from normal myocardial perfusion. Results are presented to demonstrate the proposed development using simulated gated cardiac imaging with the NURBS-based cardiac-torso (NCAT) phantom. Xiaofeng Niu, Yongyi Yang, Miles N. Wernick |
ICIP | 3 |
| 2009 | Learning a Channelized Observer for Image Quality AssessmentabstractIt is now widely accepted that image quality should be evaluated using task-based criteria, such as human-observer performance in a lesion-detection task. The channelized Hotelling observer (CHO) has been widely used as a surrogate for human observers in evaluating lesion detectability. In this paper, we propose that the problem of developing a numerical observer can be viewed as a system-identification or supervised-learning problem, in which the goal is to identify the unknown system of the human observer. Following this approach, we explore the possibility of replacing the Hotelling detector within the CHO with an algorithm that learns the relationship between measured channel features and human observer scores. Specifically, we develop a channelized support vector machine (CSVM) which we compare to the CHO in terms of its ability to predict human-observer performance. In the examples studied, we find that the CSVM is better able to generalize to unseen images than the CHO, and therefore may represent a useful improvement on the CHO methodology, while retaining its essential features. Jovan G. Brankov, Yongyi Yang, Liyang Wei, Issam El-Naqa, Miles N. Wernick |
IEEE Trans. Medical Imaging | 5 |
| 2009 | Prostate Cancer Segmentation With Simultaneous Estimation of Markov Random Field Parameters and ClassabstractProstate cancer is one of the leading causes of death from cancer among men in the United States. Currently, high-resolution magnetic resonance imaging (MRI) has been shown to have higher accuracy than trans-rectal ultrasound (TRUS) when used to ascertain the presence of prostate cancer. As MRI can provide both morphological and functional images for a tissue of interest, some researchers are exploring the uses of multispectral MRI to guide prostate biopsies and radiation therapy. However, success with prostate cancer localization based on current imaging methods has been limited due to overlap in feature space of benign and malignant tissues using any one MRI method and the interobserver variability. In this paper, we present a new unsupervised segmentation method for prostate cancer detection, using fuzzy Markov random fields (fuzzy MRFs) for the segmentation of multispectral MR prostate images. Typically, both hard and fuzzy MRF models have two groups of parameters to be estimated: the MRF parameters and class parameters for each pixel in the image. To date, these two parameters have been treated separately, and estimated in an alternating fashion. In this paper, we develop a new method to estimate the parameters defining the Markovian distribution of the measured data, while performing the data clustering simultaneously. We perform computer simulations on synthetic test images and multispectral MR prostate datasets to demonstrate the efficacy and efficiency of the proposed method and also provide a comparison with some of the commonly used methods. Deanna L. Langer, Masoom A. Haider, Yongyi Yang, Miles N. Wernick, Imam Samil Yetik |
IEEE Trans. Medical Imaging | 5 |
| 2008 | Simultaneous estimation of the Markov random field parameters and the classes for image segmentationabstractImage segmentation is a crucial step in most computer vision tasks. We propose a new unsupervised fuzzy Bayesian image segmentation method using fuzzy Markov random fields (FMRFs). FRMF is known to provide improved segmentation results when compared to the “hard” MRF method. Typically, both hard and fuzzy MRF models have two groups of parameters to be estimated: the MRF parameters and class parameters for each pixel in the image. To this date, these two parameters are treated separately, and estimated in an alternating fashion. In this paper, we develop a new method to estimate the parameters defining the Markovian distribution of the measured data, while performing the data clustering simultaneously. This is made possible by defining estimates of the MRF parameters as functions of the class parameters resulting in a cost function that depends only on the class parameters of each pixel. We apply the conjugate gradient method (CGM) to search for the optimizer of the resulting non-linear cost function. We perform computer simulations to illustrate the proposed method and provide a comparison with some of the commonly used methods. Imam Samil Yetik, Miles N. Wernick |
ICIP | 3 |
| 2008 | 4D reconstruction of cardiac images using temporal fourier basis functionsabstractIn cardiac imaging the data acquisition is often gated according to the ECG signal at the expense of signal to noise ratio in order to deal with cardiac motion. In this work, we propose a spatio-temporal reconstruction procedure by using a Fourier harmonic representation model for the temporal image activities. To further combat the increased imaging noise, we also include a spatial smoothing prior into the reconstruction process. We then reconstruct the different harmonics in the representation model by using both a penalized least-squares approach and a maximum a posteriori approach. In our experiments, the proposed approach was demonstrated using simulated cardiac SPECT perfusion imaging based on the NURBS-based cardiac-torso (NCAT) phantom. Xiaofeng Niu, Yongyi Yang, Miles N. Wernick |
ICIP | 3 |
| 2007 | Dynamic Image Reconstruction using Temporally Adaptive Regularization for Emission TomographyabstractTemporal basis functions have been found to be effective for regularizing the time-varying image activities in dynamic emission tomography. By modelling the tracer distribution function at individual pixels as a linear combination of a set of basis functions, the reconstruction problem becomes that of estimating the weights of the basis functions. In this work, we explore the use of temporally adaptive regularization in the basis function domain, where spatial smoothing is enforced in an adaptive fashion according to the time-varying data statistics. In our experiments the proposed method was demonstrated using simulated Tc99m-Teboroxime SPECT imaging with the gated mathematical cardiac-torso (gMCAT) phantom. Our results show that the proposed approach can lead to more accurate reconstruction of the time activities, which is important for differentiation between a perfusion defect and the normal myocardium. Mingwu Jin, Yongyi Yang, Miles N. Wernick |
ICIP (4) | 3 |
| 2007 | Bayesian Kernel Methods for Analysis of Functional NeuroimagesabstractWe propose an approach to analyzing functional neuroimages in which 1) regions of neuronal activation are described by a superposition of spatial kernel functions, the parameters of which are estimated from the data and 2) the presence of activation is detected by means of a generalized likelihood ratio test (GLRT). Kernel methods have become a staple of modern machine learning. Herein, we show that these techniques show promise for neuroimage analysis. In an on-off design, we model the spatial activation pattern as a sum of an unknown number of kernel functions of unknown location, amplitude, and/or size. We employ two Bayesian methods of estimating the kernel functions. The first is a maximum a posteriori (MAP) estimation method based on a Reversible-Jump Markov-chain Monte-Carlo (RJMCMC) algorithm that searches for both the appropriate model complexity and parameter values. The second is a relevance vector machine (RVM), a kernel machine that is known to be effective in controlling model complexity (and thus discouraging overfitting). In each method, after estimating the activation pattern, we test for local activation using a GLRT. We evaluate the results using receiver operating characteristic (ROC) curves for simulated neuroimaging data and example results for real fMRI data. We find that, while RVM and RJMCMC both produce good results, RVM requires far less computation time, and thus appears to be the more promising of the two approaches. Ana S. Lukic, Miles N. Wernick, Dimitris Tzikas, Aristidis Likas, Nikolas P. Galatsanos, Yongyi Yang, E. Zhao, Stephen C. Strother |
IEEE Trans. Medical Imaging | 2 |
| 2007 | Effect of Spatial Alignment Transformations in PCA and ICA of Functional NeuroimagesabstractIt has been previously observed that independent component analysis (ICA), if applied to data pooled in a particular way, may lessen the need for spatial alignment of scans in a functional neuroimaging study. In this paper, we seek to determine analytically the conditions under which this observation is true, not only for spatial ICA, but also for temporal ICA and for principal component analysis (PCA). In each case, we find conditions that the spatial alignment operator must satisfy to ensure invariance of the results. We illustrate our findings using functional magnetic-resonance imaging (fMRI) data. Our analysis is applicable to both intersubject and intrasubject spatial normalization. Ana S. Lukic, Miles N. Wernick, Yongyi Yang, Lars Kai Hansen, Konstantinos Arfanakis, Stephen C. Strother |
IEEE Trans. Medical Imaging | 2 |
| 2006 | Mammogram Retrieval by Similarity Learning from ExpertsabstractA key in content-based image retrieval is the definition of similarity measure for comparing a query image with images in a database. In this work, we explore a similarity measure based on supervised learning from expert readers for mammogram retrieval. We evaluate the approach using an observer study with a set of clinical mammograms. Our results demonstrate that the proposed supervised learning approach can be used to model the notion of similarity by expert readers in their interpretation of mammogram images, and can outperform alternative similarity measures derived from unsupervised learning. Liyang Wei, Yongyi Yang, Robert M. Nishikawa, Miles N. Wernick |
ICIP | 4 |
| 2005 | Generalized likelihood ratio test based algorithms for object recognition in photon-limited imagesabstractIn this paper the problem of detecting and localizing an object embedded in a background image from photon-limited observations is addressed. A new algorithm based on the generalized likelihood ratio test (GLRT) algorithm is formulated and compared to traditional detectors for images in photon-limited noise. We used Monte-Carlo estimation of the localization-receiver-operating characteristics (LROC) curve to evaluate the performance of the proposed algorithm quantitatively and compare it with existing methods. Our experimental results demonstrate that the proposed GLRT approach significantly outperforms traditional photon-limited detectors. Ahmad Abu-Naser, Nikolas P. Galatsanos, Miles N. Wernick |
ICIP (3) | 3 |
| 2005 | Reconstruction of cardiac-gated dynamic SPECT imagesabstractIn this work, we propose an image reconstruction procedure which will unify gated SPECT and dynamic SPECT into a single imaging method. Traditionally, gated SPECT and dynamic SPECT are treated as two distinct directions in SPECT imaging: gated SPECT aims to reconstruct a periodic stationary sequence of the cardiac cycle, while dynamic SPECT aims to obtain a time-varying distribution of the radiolabeled tracer during the study. In the proposed reconstruction procedure, we divide the cardiac cycle into a number of gate intervals as in gated SPECT, but treat the tracer distribution for each gate as a time-varying signal. By using list-mode data, this procedure produces an image sequence that shows both cardiac motion and time-varying tracer distribution. To demonstrate the proposed method, we simulated gated cardiac perfusion imaging with Tc-99m labeled Teboroxime using the 4D gated mathematical cardiac-torso (gMCAT) phantom. Preliminary results are presented to demonstrate the feasibility of the proposed approach. Mingwu Jin, Yongyi Yang, Miles N. Wernick |
ICIP (3) | 3 |
| 2005 | Relevance vector machine for automatic detection of clustered microcalcificationsabstractClustered microcalcifications (MC) in mammograms can be an important early sign of breast cancer in women. Their accurate detection is important in computer-aided detection (CADe). In this paper, we propose the use of a recently developed machine-learning technique--relevance vector machine (RVM)--for detection of MCs in digital mammograms. RVM is based on Bayesian estimation theory, of which a distinctive feature is that it can yield a sparse decision function that is defined by only a very small number of so-called relevance vectors. By exploiting this sparse property of the RVM, we develop computerized detection algorithms that are not only accurate but also computationally efficient for MC detection in mammograms. We formulate MC detection as a supervised-learning problem, and apply RVM as a classifier to determine at each location in the mammogram if an MC object is present or not. To increase the computation speed further, we develop a two-stage classification network, in which a computationally much simpler linear RVM classifier is applied first to quickly eliminate the overwhelming majority, non-MC pixels in a mammogram from any further consideration. The proposed method is evaluated using a database of 141 clinical mammograms (all containing MCs), and compared with a well-tested support vector machine (SVM) classifier. The detection performance is evaluated using free-response receiver operating characteristic (FROC) curves. It is demonstrated in our experiments that the RVM classifier could greatly reduce the computational complexity of the SVM while maintaining its best detection accuracy. In particular, the two-stage RVM approach could reduce the detection time from 250 s for SVM to 7.26 s for a mammogram (nearly 35-fold reduction). Thus, the proposed RVM classifier is more advantageous for real-time processing of MC clusters in mammograms. Liyang Wei, Yongyi Yang, Robert M. Nishikawa, Miles N. Wernick, Alexandra Edwards |
IEEE Trans. Medical Imaging | 4 |
| 2004 | Tomographic image reconstruction based on a content-adaptive mesh modelabstractIn this paper, we explore the use of a content-adaptive mesh model (CAMM) for tomographic image reconstruction. In the proposed framework, the image to be reconstructed is first represented by a mesh model, an efficient image description based on nonuniform sampling. In the CAMM, image samples (represented as mesh nodes) are placed most densely in image regions having fine detail. Tomographic image reconstruction in the mesh domain is performed by maximum-likelihood (ML) or maximum a posteriori (MAP) estimation of the nodal values from the measured data. A CAMM greatly reduces the number of unknown parameters to be determined, leading to improved image quality and reduced computation time. We demonstrated the method in our experiments using simulated gated single photon emission computed tomography (SPECT) cardiac-perfusion images. A channelized Hotelling observer (CHO) was used to evaluate the detectability of perfusion defects in the reconstructed images, a task-based measure of image quality. A minimum description length (MDL) criterion was also used to evaluate the effect of the representation size. In our application, both MDL and CHO suggested that the optimal number of mesh nodes is roughly five to seven times smaller than the number of projection bins. When compared to several commonly used methods for image reconstruction, the proposed approach achieved the best performance, in terms of defect detection and computation time. The research described in this paper establishes a foundation for future development of a (four-dimensional) space-time reconstruction framework for image sequences in which a built-in deformable mesh model is used to track the image motion. Jovan G. Brankov, Yongyi Yang, Miles N. Wernick |
IEEE Trans. Medical Imaging | 3 |
| 2004 | A similarity learning approach to content-based image retrieval: application to digital mammographyabstractIn this paper, we describe an approach to content-based retrieval of medical images from a database, and provide a preliminary demonstration of our approach as applied to retrieval of digital mammograms. Content-based image retrieval (CBIR) refers to the retrieval of images from a database using information derived from the images themselves, rather than solely from accompanying text indices. In the medical-imaging context, the ultimate aim of CBIR is to provide radiologists with a diagnostic aid in the form of a display of relevant past cases, along with proven pathology and other suitable information. CBIR may also be useful as a training tool for medical students and residents. The goal of information retrieval is to recall from a database information that is relevant to the user's query. The most challenging aspect of CBIR is the definition of relevance (similarity), which is used to guide the retrieval machine. In this paper, we pursue a new approach, in which similarity is learned from training examples provided by human observers. Specifically, we explore the use of neural networks and support vector machines to predict the user's notion of similarity. Within this framework we propose using a hierarchal learning approach, which consists of a cascade of a binary classifier and a regression module to optimize retrieval effectiveness and efficiency. We also explore how to incorporate online human interaction to achieve relevance feedback in this learning framework. Our experiments are based on a database consisting of 76 mammograms, all of which contain clustered microcalcifications (MCs). Our goal is to retrieve mammogram images containing similar MC clusters to that in a query. The performance of the retrieval system is evaluated using precision-recall curves computed using a cross-validation procedure. Our experimental results demonstrate that: 1) the learning framework can accurately predict the perceptual similarity reported by human observers, thereby serving as a basis for CBIR; 2) the learning-based framework can significantly outperform a simple distance-based similarity metric; 3) the use of the hierarchical two-stage network can improve retrieval performance; and 4) relevance feedback can be effectively incorporated into this learning framework to achieve improvement in retrieval precision based on online interaction with users; and 5) the retrieved images by the network can have predicting value for the disease condition of the query. Issam El-Naqa, Yongyi Yang, Nikolas P. Galatsanos, Robert M. Nishikawa, Miles N. Wernick |
IEEE Trans. Medical Imaging | 5 |
| 2003 | Accurate mesh representation of vector-valued (color) imagesabstractIn this work we present a fast procedure for content-adaptive mesh representation of vector-valued (e.g., color) images. The goal is to obtain a single mesh structure that accurately represents all the individual components of the image. The proposed method is justified by an error bound that is rigorously derived for such a representation. It employs an error-diffusion type algorithm to place the mesh nodes nonuniformly in the image domain according to the image content. Experimental results demonstrate that: (1) a compact and accurate representation for color images can be achieved at low computational cost by the proposed algorithm; and (2) joint treatment of the different image components by the proposed algorithm can result in a more accurate mesh representation than a mesh based on a single image component (such as intensity) alone. Jovan G. Brankov, Yongyi Yang, Miles N. Wernick |
ICIP (1) | 3 |
| 2003 | Relevance feedback based on incremental learning for mammogram retrievalabstractIn this work we explore a new technique for relevance feedback in a learning-based framework for retrieval of relevant mammogram images from a database, for purposes of aiding diagnoses. Our goal is to adapt online the learning procedure in accordance with user responses without the need to repeat the training procedure. Toward this end we develop a relevance feedback approach based on the concept of incremental learning developed recently in the theory of support vector machines. The proposed approach is demonstrated using clustered microcalcifications extracted from a database consisting of 76 mammograms. Issam El-Naqa, Yongyi Yang, Nikolas P. Galatsanos, Miles N. Wernick |
ICIP (1) | 4 |
| 2003 | A fast approach for accurate content-adaptive mesh generationabstractMesh modeling is an important problem with many applications in image processing. A key issue in mesh modeling is how to generate a mesh structure that well represents an image by adapting to its content. We propose a new approach to mesh generation, which is based on a theoretical result derived on the error bound of a mesh representation. In the proposed method, the classical Floyd-Steinberg error-diffusion algorithm is employed to place mesh nodes in the image domain so that their spatial density varies according to the local image content. Delaunay triangulation is next applied to connect the mesh nodes. The result of this approach is that fine mesh elements are placed automatically in regions of the image containing high-frequency features while coarse mesh elements are used to represent smooth areas. The proposed algorithm is noniterative, fast, and easy to implement. Numerical results demonstrate that, at very low computational cost, the proposed approach can produce mesh representations that are more accurate than those produced by several existing methods. Moreover, it is demonstrated that the proposed algorithm performs well with images of various kinds, even in the presence of noise. Yongyi Yang, Miles N. Wernick, Jovan G. Brankov |
IEEE Trans. Image Process. | 2 |
| 2002 | ML and Bayesian impulse restoration based object recognition in photon limited noiseabstractIn this paper two new object recognition and localization approaches are proposed in photon-limited noise. These approaches are based on ML and Bayesian impulse restoration (IR). For the ML approach, the expectation-maximization (EM) algorithm followed by non-linear filtering that highlights impulses is used. For the Bayesian approach, a novel prior that captures the impulsive nature of the desired solution is proposed and an extension of the EM algorithm is used to find the solution. The localization receiver operating characteristics (LROC) curve is used to quantify the performance of the proposed algorithms. Numerical experiments of an extensive Monte-Carlo study are presented. These experiments demonstrate that the proposed ML-IR approach is superior to traditional likelihood ratio detection approaches for this problem. Furthermore, they also demonstrate that the proposed Bayesian-IR framework outperforms its ML counterpart. Ahmad Abu-Naser, Nikolas P. Galatsanos, Miles N. Wernick |
ICIP (2) | 3 |
| 2002 | Similarity based clustering using the expectation maximization algorithmabstractIn this paper we present a new approach for clustering data. The clustering metric used is the normalized cross-correlation, also known as similarity, instead of the traditionally used Euclidean distance. The main advantage of this metric is that it depends on the signal shape rather than its amplitude. Under an assumption of an exponential probability model that has several desirable properties, the expectation-maximization (EM) framework is used to derive two iterative clustering algorithms. Numerical experiments are presented using simulated data in a dynamic positron emission topography study of the brain. Initial results demonstrate that the proposed method achieves better performance than several existing clustering methods. Jovan G. Brankov, Yongyi Yang, Nikolas P. Galatsanos, Miles N. Wernick |
ICIP (1) | 4 |
| 2002 | Content-adaptive mesh modeling for fully-3D tomographic image reconstructionabstractWe propose the use of a content-adaptive volumetric mesh model for fully three-dimensional (3D) tomographic image reconstruction. In the proposed framework, the image to be reconstructed is first modeled by an efficient mesh representation. The image is then obtained through estimation of the nodal values from the measured data. The use of a mesh representation can alleviate the ill-posed nature of the reconstruction problem, thereby leading to improved quality in the reconstructed images. In addition, it reduces the data storage requirement, resulting in efficient algorithms. The proposed methods are tested using gated cardiac-perfusion images. Initial results demonstrate that the proposed approach achieves good performance when compared to several commonly used methods for image reconstruction, and produces results very rapidly. Jovan G. Brankov, Yongyi Yang, Miles N. Wernick |
ICIP (2) | 3 |
| 2002 | Content-adaptive 3D mesh modeling for representation of volumetric imagesabstractIn this work we present a fast, content-adaptive approach for three-dimensional (3D) mesh representation of volumetric images. A rigorous error bound is derived for a 3D mesh representation of a volumetric image based on the theory of function interpolation. From this result, a computationally efficient algorithm is proposed for adaptive placement of mesh nodes (hence mesh elements) in the 3D image domain according to the image content. Experimental results demonstrate that a highly compact and accurate representation of volumetric images can be achieved at low computational cost by the proposed algorithm. Jovan G. Brankov, Yongyi Yang, Miles N. Wernick |
ICIP (3) | 3 |
| 2002 | Content-based image retrieval for digital mammographyabstractIn this work, we explore the use of a learning-based framework for retrieval of relevant mammogram images from a database, for purposes of aiding diagnoses. A fundamental issue is how to characterize the notion of similarity between images for use in assessing relevance of images in the database. We investigate the use of several learning algorithms, namely, neural networks and support vector machines, in a two-stage hierarchical learning network for predicting the perceptual similarity from similarity scores collected in human-observer studies. The proposed approach is demonstrated using microcalcification clusters extracted from a database consisting of 76 mammograms. Initial results demonstrate that the proposed two-stage hierarchical learning network outperforms a single-stage learning network. Issam El-Naqa, Yongyi Yang, Miles N. Wernick, Nikolas P. Galatsanos |
ICIP (3) | 3 |
| 2002 | A support vector machine approach for detection of microcalcifications in mammogramsabstractMicrocalcification (MC) clusters in mammograms can be an indicator of breast cancer. We propose, for the first time, the use of support vector machine (SVM) learning for automated detection of MCs in digitized mammograms. In the proposed framework, MC detection is formulated as a supervised-learning problem and the method of SVM is employed to develop the detection algorithm. The proposed method is developed and evaluated using a database of 76 mammograms containing 1120 MCs. To evaluate detection performance, free-response receiver operating characteristic (FROC) curves are used. Experimental results demonstrate that, when compared to several other existing methods, the proposed SVM framework offers the best performance. Issam El-Naqa, Yongyi Yang, Miles N. Wernick, Nikolas P. Galatsanos, Robert M. Nishikawa |
ICIP (2) | 3 |
| 2002 | An ICA algorithm for analyzing multiple data setsabstractWe derive an independent-component analysis (ICA) method for analyzing two or more data sets simultaneously. Our model permits there to be components individual to the various data sets, and others that are common to all the sets. We explore the assumed time autocorrelation of independent signal components and base our algorithm on prediction analysis. We illustrate the algorithm using a simple image separation example. Our aim is to apply this method to functional brain mapping using functional magnetic resonance imaging (fMRI). Ana S. Lukic, Lars Kai Hansen, Miles N. Wernick, Stephen C. Strother |
ICIP (2) | 3 |
| 2002 | A reversible jump Markov chain Monte Carlo algorithm for analysis of functional neuroimagesabstractWe propose a new signal-detection approach for detecting brain activations from PET or fMRI images in a two-state ("on-off") neuroimaging study. We model the activation pattern as a superposition of an unknown number of circular spatial basis functions of unknown position, size, and amplitude. We determine the number of these functions and their parameters by maximum a posteriori (MAP) estimation. To maximize the posterior distribution we use a reversible jump Markov-chain Monte-Carlo (RJMCMC) algorithm. The main advantage of RJMCMC is that it can estimate parameter vectors of unknown length. Thus, in the model used the number of activation sites does not need to be known. Using a phantom derived from a neuroimaging study, we demonstrate that the proposed method can estimate more accurately the activation pattern from traditional approaches. Ana S. Lukic, Miles N. Wernick, Nikolas P. Galatsanos, Yongyi Yang, Stephen C. Strother |
ICIP (3) | 2 |
| 2002 | An evaluation of methods for detecting brain activations from functional neuroimages
Ana S. Lukic, Miles N. Wernick, Stephen C. Strother |
Artif. Intell. Medicine | 2 |
| 2002 | A Support Vector Machine Approach for Detection of MicrocalcificationsabstractIn this paper, we investigate an approach based on support vector machines (SVMs) for detection of microcalcification (MC) clusters in digital mammograms, and propose a successive enhancement learning scheme for improved performance. SVM is a machine-learning method, based on the principle of structural risk minimization, which performs well when applied to data outside the training set. We formulate MC detection as a supervised-learning problem and apply SVM to develop the detection algorithm. We use the SVM to detect at each location in the image whether an MC is present or not. We tested the proposed method using a database of 76 clinical mammograms containing 1120 MCs. We use free-response receiver operating characteristic curves to evaluate detection performance, and compare the proposed algorithm with several existing methods. In our experiments, the proposed SVM framework outperformed all the other methods tested. In particular, a sensitivity as high as 94% was achieved by the SVM method at an error rate of one false-positive cluster per image. The ability of SVM to out perform several well-known methods developed for the widely studied problem of MC detection suggests that SVM is a promising technique for object detection in a medical imaging application. Issam El-Naqa, Yongyi Yang, Miles N. Wernick, Nikolas P. Galatsanos, Robert M. Nishikawa |
IEEE Trans. Medical Imaging | 3 |
| 2001 | Tomographic image reconstruction using content-adaptive mesh modelingabstractWe propose the use of a content-adaptive mesh model (CAMM) for tomographic image reconstruction. In the proposed framework, the image to be reconstructed is first modeled by an efficient mesh representation. The image is then obtained through estimation of the nodal values from the measured data. The use of a CAMM can greatly alleviate the ill-posed nature of the reconstruction problem, thereby leading to improved quality in the reconstructed images. In addition, it can lead to development of efficient numerical reconstruction algorithms. Finally, it can be useful for motion-tracking of image sequences. The proposed methods are tested using simulated gated cardiac-perfusion SPECT images. Our results indicate that, among the methods tested, the proposed approach achieves the best performance in terms of image quality and computation time, and can also reduce the memory requirement. Jovan G. Brankov, Yongyi Yang, Miles N. Wernick |
ICIP (1) | 3 |
| 2001 | A fast algorithm for accurate content-adaptive mesh generationabstractPreviously, we proposed a computationally efficient approach to content-adaptive mesh generation used for image representation (see Lee, J. et al., IEEE Int. Conf. Image Proc., 2000). We now provide a theoretical basis for that method, which leads to an improved version of the algorithm. An error bound is derived for a mesh representation of an image based on the theory of function interpolation. From this result, a more accurate scheme is proposed for placement of mesh elements in the image domain according to the image content. Experimental results, compared to other methods, show that a highly accurate image representation can be obtained at extremely low computational cost by the proposed technique. Jovan G. Brankov, Yongyi Yang, Miles N. Wernick |
ICIP (3) | 3 |
| 2000 | Image Retrieval Based on Similarity LearningabstractWe explore the use of various learning algorithms to predict the user's measure of similarity between a given query image and images in a database. Our aim is to obtain a similarity coefficient, for use in image retrieval, that more accurately reflects that of the user. The performance of a variety of learning machines was evaluated using statistical resampling to estimate the prediction error and retrieval effectiveness. The proposed approach was demonstrated using synthetic shape and texture examples. The results of the study are very promising, especially those obtained by the general regression neural network and the support vector machine/radial basis function method. Issam El-Naqa, Miles N. Wernick, Yongyi Yang, Nikolas P. Galatsanos |
ICIP | 2 |
| 2000 | A New Approach for Image-Content Adaptive Mesh GenerationabstractA new, effective approach is proposed for content-adaptive mesh generation used for image representation. The proposed approach employs the Floyd-Steinberg (1975) method, a classical error-diffusion algorithm for image halftoning, to distribute the mesh nodes in the domain of an image based on its gradient magnitude. Consequently, fine mesh elements are placed automatically in regions of the image containing high-frequency features while coarse mesh elements are used in smooth regions. The proposed algorithm is non-iterative and easy to implement. Numerical results demonstrate that it can yield a compact, accurate representation of images. Yongyi Yang, Miles N. Wernick |
ICIP | 3 |
| 2000 | Improved image quality and computation reduction in 4D reconstruction of cardiac gated SPECT imagesabstractSpatiotemporal reconstruction of cardiac-gated SPECT images permits us to obtain valuable information related to cardiac function. However, the task of reconstructing this four-dimensional (4-D) data set is computation intensive. Typically, these studies are reconstructed frame-by-frame: a nonoptimal approach because temporal correlations in the signal are not accounted for. In this work, we show that the compression and signal decorrelation properties of the Karhunen-Loève (KL) transform may be used to greatly simplify the spatiotemporal reconstruction problem. The gated projections are first KL transformed in the temporal direction. This results in a sequence of KL-transformed projection images for which the signal components are uncorrelated along the time axis. As a result, the 4-D reconstruction task is simplified to a series of three-dimensional (3-D) reconstructions in the KL domain. The reconstructed KL components are subsequently inverse KL transformed to obtain the entire spatiotemporal reconstruction set. Our simulation and clinical results indicate that KL processing provides image sequences that are less noisy than are conventional frame-by-frame reconstructions. Additionally, by discarding high-order KL components that are dominated by noise, we can achieve savings in computation time because fewer reconstructions are needed in comparison to conventional frame-by-frame reconstructions. Manoj V. Narayanan, Michael A. King, Miles N. Wernick, Charles L. Byrne, Edward J. Soares, P. Hendrik Pretorius |
IEEE Trans. Medical Imaging | 3 |
| 1999 | Tomographic Image Reconstruction for Systems with Partially-Known BlurabstractIn tomographic image reconstruction, it is usually assumed that the system matrix is known exactly, although this is not usually the case in practice. We investigate the potential benefit of modeling the system matrix as the sum of a known part and an unknown random error. Using some of simplifying assumptions, we develop a penalized weighted least squares (PWLS) reconstruction algorithm for this problem. Our experiments indicate that this approach can, indeed lead to significant improvements in the reconstructed image, both visually and quantitatively. Jovan G. Brankov, Jaksa Djordjevic, Miles N. Wernick, Nikolas P. Galatsanos |
ICIP (3) | 3 |
| 1999 | Fast Optimal Image Reconstruction for Dynamic PETabstractIn tomographic imaging, dynamic images are typically obtained by reconstructing the frames of a time sequence independently, one by one. A disadvantage of this frame-by-frame reconstruction approach is that it fails to account. For temporal correlations in the signal. Ideally, one should treat the entire image sequence as a single spatio-temporal signal. However, the resulting reconstruction task becomes computationally intensive. Fortunately, as the authors show in this paper, the spatio-temporal reconstruction problem call be greatly simplified by first applying a temporal Karhunen-Loeve (KL) transformation to the imaging equation. The authors show that if the regularization operator is chosen to be separable into space and time components, penalized weighted least squares reconstruction of the entire image sequence is approximately equivalent to frame-by-frame reconstruction in the space-KL domain. By this approach, spatio-temporal reconstruction can be achieved at reasonable computational cost. One can achieve further computational savings by discarding high-order KL components to avoid reconstructing them. Performance of the method is demonstrated through statistical evaluations of the bias-variance tradeoff obtained by computer simulation reconstruction. Miles N. Wernick, E. James Infusino, Milos Milosevic |
IEEE Trans. Medical Imaging | 1 |
| 1997 | Impulse restoration-based template-matching using the expectation-maximization algorithmabstractIt has been demonstrated that object recognition can be formulated as an image-restoration problem. In this approach, which we term impulse restoration, the objective is to restore a delta function indicating the object's location. We develop solutions based on impulse restoration for the Gaussian noise case. We propose a new iterative approach, based on the expectation-maximization (EM) algorithm, that simultaneously estimates the background statistics and restores a delta function at the location of the template. We use localization-receiver-operating characteristics (LROC) curves to evaluate quantitatively the performance of this approach and compare it with existing methods. We present experimental results that demonstrate that impulse restoration is a powerful approach for detecting known objects in images severely degraded by noise. Our experiments demonstrate that accurate modeling and estimation of the background and noise statistics are essential to successful object detection. Ahmad Abu-Naser, Nikolas P. Galatsanos, Miles N. Wernick |
ICIP (3) | 3 |
| 1997 | Image Reconstruction for Dynamic PET Based on Low-Order Approximation and Restoration of the SinogramabstractMany image-reconstruction methods have been proposed to improve the spatial resolution of positron emission tomography (PET) images and, thus, to produce better quantification. However, these techniques, which are designed for static images, may be inadequate for good reconstruction from dynamic data. We present a simple, but effective, reconstruction approach intended specifically for dynamic studies. First, the level of noise in dynamic PET data is reduced by smoothing along the time axis using a low-order approximation. Next, the denoised sinograms are restored spatially by the method of projections onto convex sets. Finally, images are reconstructed from the restored sinograms by ordinary filtered backprojection. We present experimental results that demonstrate substantial improvements in region-of-interest quantification in actual and simulated dopamine D-2 neuroreceptor-imaging studies of a monkey brain. Chien-Min Kao, Jeffrey T. Yap, Jogeshwar Mukherjee, Miles N. Wernick |
IEEE Trans. Medical Imaging | 4 |
| 1995 | Iterative maximum a posteriori (MAP) restoration from partially-known blur for tomographic reconstructionabstractAn iterative maximum a posteriori (MAP) algorithm is proposed for simultaneous signal-covariance estimation and restoration when only partial knowledge of the system response matrix (SRM) and the noisy-blurred sinogram of an image to be reconstructed are available. Convergence analysis is performed to ascertain that the proposed covariance estimator converges to the optimal one in the MAP sense. The superiority of the proposed algorithm, in comparison with the iterative linear minimum mean-squared-error (LMMSE) filter for incorrect SRM information, is experimentally verified. Vladimir Z. Mesarovic, Nikolas P. Galatsanos, Miles N. Wernick |
ICIP | 3 |
| 1994 | Lossless Compression of Multi-Dimensional Medical Image Data using Binary-Decomposed High-Order Entropy CodingabstractInformation theory indicates that coding efficiency can be improved by utilizing high-order entropy coding (HOEC). However, serious implementation difficulties limit the practical value of HOEC for grayscale image compression. We present a new approach, called binary-decomposed (BD) high-order entropy coding, that significantly reduces the complexity of the implementation and increases the accuracy in estimating the statistical model. In this approach a grayscale image is first decomposed into a group of binary sub-images, each corresponding to one of the gray levels. When HOEC is applied to these sub-images instead of the original image, the subsequent coding is made simpler and more accurate statistically. We apply this coding technique in lossless compression of medical images and imaging data, and demonstrate that the performance advantage of this approach is significant.> Steve S. Yu, Miles N. Wernick, Nikolas P. Galatsanos |
ICIP (2) | 2 |