Demo Data from SIGIR 2026 / reviewers in the wild / expert
Yoshikazu Nakajima
dblp:67/4667
· DBLP profile ↗
18ranked-venue papers
3as first author
1since 2021 · last 2022
0000-0003-3067-6290ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 11 · 2 first-authorGraphics, computer vision, multimedia, augmented reality and games · 9 · 2 first-authorArtificial intelligence and machine learning · 7 · 1 first-author · 1 since 2021Systems, architecture and hardware · 5 · 1 since 2021
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
4 papers |
Robot manipulation · 83% Efficient and distributed learning · 12% Motion planning and robot control · 3% | |
| Human-computer interaction and pervasive computing
1 paper |
Accessibility and assistive technology · 100% | |
| Interdisciplinary, comprehensive, and emerging computing
3 papers |
Medical and health informatics · 100% |
Topics — the 8 heaviest of 9, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Robot manipulation › actuation
pneumatic artificial muscle |
0.6 | 1 | 2022 | Online Assistance Control of a Pneumatic Gait Assistive Suit Using Physical Reservoir Computing Exploiting Air Dynamics · ICRA 2022 |
Robotics › Robot manipulation › soft robotics
soft actuator |
0.6 | 1 | 2022 | Online Assistance Control of a Pneumatic Gait Assistive Suit Using Physical Reservoir Computing Exploiting Air Dynamics · ICRA 2022 |
Accessibility and assistive technology › locomotion assistance
gait assistance |
0.6 | 1 | 2022 | Online Assistance Control of a Pneumatic Gait Assistive Suit Using Physical Reservoir Computing Exploiting Air Dynamics · ICRA 2022 |
Medical and health informatics › computer-assisted surgery
computer-assisted orthopedic surgery |
0.2 | 3 | 2008 | Deformation analysis and active compensation of surgical milling robot based on system error evaluation · ICRA 2008 Toolpath Optimization for a Milling Robot of Minimally Invasive Orthopedic Surgery · ICRA 2007 Adaptive Controlled Milling Robot for Orthopedic Surgery · ICRA 2007 |
Machine learning › Optimization for machine learning
error compensation |
0.0 | 1 | 2008 | Deformation analysis and active compensation of surgical milling robot based on system error evaluation · ICRA 2008 |
Robotics › Motion planning and robot control
collision avoidance |
0.0 | 1 | 2007 | Toolpath Optimization for a Milling Robot of Minimally Invasive Orthopedic Surgery · ICRA 2007 |
Robotics › Motion planning and robot control › robot control
force control |
0.0 | 1 | 2007 | Adaptive Controlled Milling Robot for Orthopedic Surgery · ICRA 2007 |
Image and video processing
motion analysis |
0.0 | 1 | 1997 | Acquisition of Symbolic Description from Flow Fields: A New Approach Based on a Fluid Model · IEEE Trans. Pattern Anal. Mach. Intell. 1997 |
Methods — techniques the papers use, named apart from their topics
pneumatic analog computation · 1.1physical reservoir computing · 1.1error map · 0.2active compensation · 0.2redundant axis · 0.1predictive mode · 0.1geometric optimization · 0.1adaptive control · 0.1holomorphic complex function theory · 0.0fluid model · 0.0
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2022 | Online Assistance Control of a Pneumatic Gait Assistive Suit Using Physical Reservoir Computing Exploiting Air DynamicsabstractWearable gait assistive devices have been im-proved by soft robotics in terms of safety and physical burden of the wearer. Currently, electrical sensors and computers around the wearer are bottlenecks in enhancing the wearer's activities. In this paper, we present a wearable gait assistive system using soft pneumatic system for all the actuation, sensing, and computation. Pneumatic artifical muscles (PAMs) on the thighs were used to generate assistance force, and thin PAMs on the whole legs were used for sensing the wearer's motion. All thin PAMs were connected to each other by tubes, and the pressure response in the tubes were exploited to compute the wearer's motion in manner of physical reservoir computing. The left thigh angular velocity estimated from the reservoir response was used for control the PAMs for actuation. Our experiment with the use of gait assistance showed that the system worked correctly. This paper shows that the pneumatic analog computation system for sensing soft body can help the functionality of soft wearable assistive devices. Hiroyuki Hayashi, Toshihiro Kawase, Tetsuro Miyazaki, Maina Sogabe, Yoshikazu Nakajima, Kenji Kawashima |
ICRA | 5 |
| 2010 | Hazard analysis of fracture-reduction robot and its application to safety design of fracture-reduction assisting robotic systemabstractIn this paper, we discuss the issue of safety in robot-assisted fracture reduction. We define the hazards of robot-assisted fracture reduction and design safety control methods. Although a large reduction force is required to reduce femoral neck fractures, an unexpectedly large force produced by a robot may cause injury to the patient. We have designed two mechanical failsafe units and a software force limiter; this along with velocity control can guarantee a safe operation in reduction force. In addition, to reduce the movement of bone fragments as much as possible, we devised spatially constrained control methods for fracture-reduction robots. The fracture-reduction system was evaluated using simulated fracture reductions. Sanghyun Joung, Hongen Liao, Etsuko Kobayashi, Mamoru Mitsuishi, Yoshikazu Nakajima, Nobuhiko Sugano, Masahiko Bessho, Satoru Ohashi, Takuya Matsumoto, Isao Ohnishi, Ichiro Sakuma |
ICRA | 5 |
| 2008 | Deformation analysis and active compensation of surgical milling robot based on system error evaluationabstractThe increase of precision and minimal invasiveness is an important current issue in orthopedic surgery. The femur and the tibia must be shaped to fit an artificial joint for successful knee arthroplasty. The recent trend towards MIS (Minimally Invasive Surgery) to decrease the length of the required incision has increased surgical difficulty, since the open access area is small. In this paper, registration and cutting error were analyzed with a robotic surgery system being developed first as an example, and a method of active compensation of robot deformation by gravity and cutting force was proposed and tried based on the error map with the expectation that the precision will increase. Naohiko Sugita, Takayuki Osa, Yoshikazu Nakajima, Mamoru Mitsuishi |
ICRA | 3 |
| 2008 | A Robot Assisted Hip Fracture Reduction with a Navigation System
Sanghyun Joung, Hirokazu Kamon, Hongen Liao, Junichiro Iwaki, Touji Nakazawa, Mamoru Mitsuishi, Yoshikazu Nakajima, Tsuyoshi Koyama, Nobuhiko Sugano, Yuki Maeda, Masahiko Bessho, Satoru Ohashi, Takuya Matsumoto, Isao Ohnishi, Ichiro Sakuma |
MICCAI (2) | 7 |
| 2007 | Adaptive Controlled Milling Robot for Orthopedic SurgeryabstractAdaptive control of the machining process in orthopedic surgery will increase not only productivity but also the safety issues of tool usage. The authors have developed a technology for an adaptive control system. The system has two modes, the "predictive mode" and the "adaptive mode." The predictive mode is used to shorten the air cutting time. In the adaptive mode, the system monitors the cutting force and the cutting temperature, and controls the feed override according to the difference between the real and the desired cutting force. The software is implemented on the robot controller and its effectiveness is evaluated with a urethane bone. Naohiko Sugita, Fumiaki Genma, Yoshikazu Nakajima, Mamoru Mitsuishi |
ICRA | 3 |
| 2007 | Toolpath Optimization for a Milling Robot of Minimally Invasive Orthopedic SurgeryabstractToolpath generation and optimization is considered as a challenging problem in the minimally invasive orthopedic surgery with a milling robot. The objective of this paper is to minimize the collision of the cutting tool with the soft tissues. A novel approach of toolpath generation and optimization is proposed. A redundant axis is implemented to avoid the collision in the robot. Some important components are modeled based on the physical requirements. A geometric optimization approach based on the model is proposed to improve the toolpath. Case studies show the validity of this approach. Software is developed for this application and the effectiveness is evaluated with a cadaveric bone. Naohiko Sugita, Fumiaki Genma, Yoshikazu Nakajima, Mamoru Mitsuishi |
ICRA | 3 |
| 2007 | Cutting Tool System to Minimize Soft Tissue Damage for Robot-Assisted Minimally Invasive Orthopedic Surgery
Naohiko Sugita, Yoshikazu Nakajima, Mamoru Mitsuishi, Shosaku Kawata, Kazuo Fujiwara, Nobuhiro Abe, Toshifumi Ozaki, Masahiko Suzuki |
MICCAI (1) | 2 |
| 2005 | Development of the Needle Insertion Robot for Percutaneous Vertebroplasty
Shinya Onogi, K. Morimoto, Ichiro Sakuma, Yoshikazu Nakajima, Tsuyoshi Koyama, Nobuhiko Sugano, Yuichi Tamura, S. Yonenobu, Yasuyuki Momoi |
MICCAI (2) | 4 |
| 2004 | Improvement of depth position in 2-D/3-D registration of knee implants using single-plane fluoroscopyabstractTwo-dimensional (2-D)/three-dimensional (3-D) registration techniques using single-plane fluoroscopy are highly important for analyzing 3-D kinematics in applications such as total knee arthroplasty (TKA) implants. The accuracy of single-plane fluoroscopy-based techniques in the determination of translation perpendicular to the image plane (depth position), however, is relatively poor because a change in the depth position causes only small changes in the 2-D silhouette. Accuracies achieved in depth position using conventional 2-D/3-D registration techniques are insufficient for clinical applications. Therefore, we propose a technique for improving the accuracy of depth position determination in order to develop a system for analyzing knee kinematics over the full six degrees of freedom (6 DOF) using single-plane fluoroscopy. In preliminary experiments, the behaviors of errors for each free variable were quantified as evaluation curves by examining changes in cost function with variations in the free variable. The evaluation curve for depth position was more jagged, and the curve peak less pointy, compared to the evaluation curves of the other five variables, and the curve was found to behave differently. Depth position is therefore optimized independently of the other variables, using an approximate evaluation curve of depth position prepared after initial registration. Accuracy of the proposed technique was evaluated by computer simulation and in vitro tests, with validation of absolute position and orientation performed for each knee component. In computer simulation tests, root-mean-square error (RMSE) in depth position was improved from 2.6 mm (conventional) to 0.9 mm (proposed), whereas for in vitro tests, RMSE improved from 3.2 mm to 1.4 mm. Accuracy of the estimation of the remaining two translational and three rotational variables was found to be almost the same as that obtained by conventional techniques. Results of in vivo tests are also described in which the possibility of full 6 DOF kinematic analysis of TKA implants is shown. Takaharu Yamazaki, Tetsu Watanabe, Yoshikazu Nakajima, Kazuomi Sugamoto, Tetsuya Tomita, Hideki Yoshikawa, Shinichi Tamura |
IEEE Trans. Medical Imaging | 3 |
| 2003 | Camera Model and Calibration Procedure for Oblique-Viewing Endoscope
Tetsuzo Yamaguchi, Masahiko Nakamoto, Yoshinobu Sato, Yoshikazu Nakajima, Kozo Konishi, Makoto Hashizume, Takashi Nishii, Nobuhiko Sugano, Hideki Yoshikawa, Kazuo Yonenobu, Shinichi Tamura |
MICCAI (2) | 4 |
| 2003 | Physics-based flow estimation of fluids
Yoshikazu Nakajima, Hiroshi Inomata, Hiroki Nogawa, Yoshinobu Sato, Shinichi Tamura, Kozo Okazaki, Seiji Torii |
Pattern Recognit. | 1 |
| 2002 | Preoperative Analysis of Optimal Imaging Orientation in Fluoroscopy for Voxel-Based 2-D/3-D Registration
Yoshikazu Nakajima, Yuichi Tamura, Yoshinobu Sato, Takahito Tashiro, Nobuhiko Sugano, Kazuo Yonenobu, Hideki Yoshikawa, Takahiro Ochi, Shinichi Tamura |
MICCAI (2) | 1 |
| 2002 | 3D Ultrasound System Using a Magneto-optic Hybrid Tracker for Augmented Reality Visualization in Laparoscopic Liver Surgery
Masahiko Nakamoto, Yoshinobu Sato, Masaki Miyamoto, Yoshikazu Nakajima, Kozo Konishi, Mitsuo Shimada, Makoto Hashizume, Shinichi Tamura |
MICCAI (2) | 4 |
| 2002 | A Novel Laser Guidance System for Alignment of Linear Surgical Tools: Its Principles and Performance Evaluation as a Man-Machine System
Toshihiko Sasama, Nobuhiko Sugano, Yoshinobu Sato, Yasuyuki Momoi, Tsuyoshi Koyama, Yoshikazu Nakajima, Ichiro Sakuma, Masakatsu G. Fujie, Kazuo Yonenobu, Takahiro Ochi, Shinichi Tamura |
MICCAI (2) | 6 |
| 2001 | Accuracy Validation of Cone-Beam CT Based Registration
Yoshikazu Nakajima, Toshihiko Sasama, Yoshinobu Sato, Takashi Nishii, Nobuhiko Sugano, Takashi Ishikawa, Kazuo Yonenobu, Takahiro Ochi, Shinichi Tamura |
MICCAI | 1 |
| 2001 | 3D Ultrasound Image Acquisition Using a Magneto-optic Hybrid Sensor for Laparoscopic Surgery
Yoshinobu Sato, Masaki Miyamoto, Masahiko Nakamoto, Yoshikazu Nakajima, Mitsuo Shimada, Makoto Hashizume, Shinichi Tamura |
MICCAI | 4 |
| 1998 | Image guidance of breast cancer surgery using 3D ultrasonic images and augmented reality visualizationabstractThis paper describes augmented reality visualization for the guidance of breast-conservative cancer surgery using ultrasonic images acquired in the operating room just before surgical resection. By combining an optical three-dimensional (3-D) position sensor, the position and orientation of each ultrasonic cross section are precisely measured to reconstruct geometrically accurate 3-D tumor models from the acquired ultrasonic images. Similarly, the 3-D position and orientation of a video camera are obtained to integrate video and ultrasonic images in a geometrically accurate manner. Superimposing the 3-D tumor models onto live video images of the patient's breast enables the surgeon to perceive the exact 3-D position of the tumor, including irregular cancer invasions which cannot be perceived by touch, as if it were visible through the breast skin. Using the resultant visualization, the surgeon can determine the region for surgical resection in a more objective and accurate manner, thereby minimizing the risk of a relapse and maximizing breast conservation. The system was shown to be effective in experiments using phantom and clinical data. Yoshinobu Sato, Masahiko Nakamoto, Toshihiko Sasama, Yasuhiro Tamaki, I. Sakita, Yoshikazu Nakajima, Shinichi Tamura, Morito Monden |
IEEE Trans. Medical Imaging | 6 |
| 1997 | Acquisition of Symbolic Description from Flow Fields: A New Approach Based on a Fluid ModelabstractWe propose a new model and new algorithm for acquiring symbolic description from a flow field. Our model is derived from physical data, and our algorithm is based on holomorphic complex function theory. Application of this method enables both qualitative and quantitative information to be obtained from a flow field. We also demonstrate the robustness of our method using a simulated flow field and a real image sequence. Hiroki Nogawa, Yoshikazu Nakajima, Yoshinobu Sato, Shinichi Tamura |
IEEE Trans. Pattern Anal. Mach. Intell. | 2 |