Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Yoshikazu Nakajima

dblp:67/4667 · DBLP profile ↗
← Back
18ranked-venue papers
3as first author
1since 2021 · last 2022
0000-0003-3067-6290ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 11 · 2 first-authorGraphics, computer vision, multimedia, augmented reality and games · 9 · 2 first-authorArtificial intelligence and machine learning · 7 · 1 first-author · 1 since 2021Systems, architecture and hardware · 5 · 1 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
4 papers
Robot manipulation · 83% Efficient and distributed learning · 12% Motion planning and robot control · 3%
Human-computer interaction and pervasive computing
1 paper
Accessibility and assistive technology · 100%
Interdisciplinary, comprehensive, and emerging computing
3 papers
Medical and health informatics · 100%

Topics — the 8 heaviest of 9, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation › actuation
pneumatic artificial muscle
0.612022
Online Assistance Control of a Pneumatic Gait Assistive Suit Using Physical Reservoir Computing Exploiting Air Dynamics · ICRA 2022
Robotics › Robot manipulation › soft robotics
soft actuator
0.612022
Online Assistance Control of a Pneumatic Gait Assistive Suit Using Physical Reservoir Computing Exploiting Air Dynamics · ICRA 2022
Accessibility and assistive technology › locomotion assistance
gait assistance
0.612022
Online Assistance Control of a Pneumatic Gait Assistive Suit Using Physical Reservoir Computing Exploiting Air Dynamics · ICRA 2022
Medical and health informatics › computer-assisted surgery
computer-assisted orthopedic surgery
0.232008
Deformation analysis and active compensation of surgical milling robot based on system error evaluation · ICRA 2008
Toolpath Optimization for a Milling Robot of Minimally Invasive Orthopedic Surgery · ICRA 2007
Adaptive Controlled Milling Robot for Orthopedic Surgery · ICRA 2007
Machine learning › Optimization for machine learning
error compensation
0.012008
Deformation analysis and active compensation of surgical milling robot based on system error evaluation · ICRA 2008
Robotics › Motion planning and robot control
collision avoidance
0.012007
Toolpath Optimization for a Milling Robot of Minimally Invasive Orthopedic Surgery · ICRA 2007
Robotics › Motion planning and robot control › robot control
force control
0.012007
Adaptive Controlled Milling Robot for Orthopedic Surgery · ICRA 2007
Image and video processing
motion analysis
0.011997
Acquisition of Symbolic Description from Flow Fields: A New Approach Based on a Fluid Model · IEEE Trans. Pattern Anal. Mach. Intell. 1997

Methods — techniques the papers use, named apart from their topics

pneumatic analog computation · 1.1physical reservoir computing · 1.1error map · 0.2active compensation · 0.2redundant axis · 0.1predictive mode · 0.1geometric optimization · 0.1adaptive control · 0.1holomorphic complex function theory · 0.0fluid model · 0.0
YearPublicationVenuePosition
2022 Online Assistance Control of a Pneumatic Gait Assistive Suit Using Physical Reservoir Computing Exploiting Air Dynamics
abstract
Wearable gait assistive devices have been im-proved by soft robotics in terms of safety and physical burden of the wearer. Currently, electrical sensors and computers around the wearer are bottlenecks in enhancing the wearer's activities. In this paper, we present a wearable gait assistive system using soft pneumatic system for all the actuation, sensing, and computation. Pneumatic artifical muscles (PAMs) on the thighs were used to generate assistance force, and thin PAMs on the whole legs were used for sensing the wearer's motion. All thin PAMs were connected to each other by tubes, and the pressure response in the tubes were exploited to compute the wearer's motion in manner of physical reservoir computing. The left thigh angular velocity estimated from the reservoir response was used for control the PAMs for actuation. Our experiment with the use of gait assistance showed that the system worked correctly. This paper shows that the pneumatic analog computation system for sensing soft body can help the functionality of soft wearable assistive devices.
Hiroyuki Hayashi, Toshihiro Kawase, Tetsuro Miyazaki, Maina Sogabe, Yoshikazu Nakajima, Kenji Kawashima
ICRA5
2010 Hazard analysis of fracture-reduction robot and its application to safety design of fracture-reduction assisting robotic system
abstract
In this paper, we discuss the issue of safety in robot-assisted fracture reduction. We define the hazards of robot-assisted fracture reduction and design safety control methods. Although a large reduction force is required to reduce femoral neck fractures, an unexpectedly large force produced by a robot may cause injury to the patient. We have designed two mechanical failsafe units and a software force limiter; this along with velocity control can guarantee a safe operation in reduction force. In addition, to reduce the movement of bone fragments as much as possible, we devised spatially constrained control methods for fracture-reduction robots. The fracture-reduction system was evaluated using simulated fracture reductions.
Sanghyun Joung, Hongen Liao, Etsuko Kobayashi, Mamoru Mitsuishi, Yoshikazu Nakajima, Nobuhiko Sugano, Masahiko Bessho, Satoru Ohashi, Takuya Matsumoto, Isao Ohnishi, Ichiro Sakuma
ICRA5
2008 Deformation analysis and active compensation of surgical milling robot based on system error evaluation
abstract
The increase of precision and minimal invasiveness is an important current issue in orthopedic surgery. The femur and the tibia must be shaped to fit an artificial joint for successful knee arthroplasty. The recent trend towards MIS (Minimally Invasive Surgery) to decrease the length of the required incision has increased surgical difficulty, since the open access area is small. In this paper, registration and cutting error were analyzed with a robotic surgery system being developed first as an example, and a method of active compensation of robot deformation by gravity and cutting force was proposed and tried based on the error map with the expectation that the precision will increase.
Naohiko Sugita, Takayuki Osa, Yoshikazu Nakajima, Mamoru Mitsuishi
ICRA3
2008 A Robot Assisted Hip Fracture Reduction with a Navigation System
Sanghyun Joung, Hirokazu Kamon, Hongen Liao, Junichiro Iwaki, Touji Nakazawa, Mamoru Mitsuishi, Yoshikazu Nakajima, Tsuyoshi Koyama, Nobuhiko Sugano, Yuki Maeda, Masahiko Bessho, Satoru Ohashi, Takuya Matsumoto, Isao Ohnishi, Ichiro Sakuma
MICCAI (2)7
2007 Adaptive Controlled Milling Robot for Orthopedic Surgery
abstract
Adaptive control of the machining process in orthopedic surgery will increase not only productivity but also the safety issues of tool usage. The authors have developed a technology for an adaptive control system. The system has two modes, the "predictive mode" and the "adaptive mode." The predictive mode is used to shorten the air cutting time. In the adaptive mode, the system monitors the cutting force and the cutting temperature, and controls the feed override according to the difference between the real and the desired cutting force. The software is implemented on the robot controller and its effectiveness is evaluated with a urethane bone.
Naohiko Sugita, Fumiaki Genma, Yoshikazu Nakajima, Mamoru Mitsuishi
ICRA3
2007 Toolpath Optimization for a Milling Robot of Minimally Invasive Orthopedic Surgery
abstract
Toolpath generation and optimization is considered as a challenging problem in the minimally invasive orthopedic surgery with a milling robot. The objective of this paper is to minimize the collision of the cutting tool with the soft tissues. A novel approach of toolpath generation and optimization is proposed. A redundant axis is implemented to avoid the collision in the robot. Some important components are modeled based on the physical requirements. A geometric optimization approach based on the model is proposed to improve the toolpath. Case studies show the validity of this approach. Software is developed for this application and the effectiveness is evaluated with a cadaveric bone.
Naohiko Sugita, Fumiaki Genma, Yoshikazu Nakajima, Mamoru Mitsuishi
ICRA3
2007 Cutting Tool System to Minimize Soft Tissue Damage for Robot-Assisted Minimally Invasive Orthopedic Surgery
Naohiko Sugita, Yoshikazu Nakajima, Mamoru Mitsuishi, Shosaku Kawata, Kazuo Fujiwara, Nobuhiro Abe, Toshifumi Ozaki, Masahiko Suzuki
MICCAI (1)2
2005 Development of the Needle Insertion Robot for Percutaneous Vertebroplasty
Shinya Onogi, K. Morimoto, Ichiro Sakuma, Yoshikazu Nakajima, Tsuyoshi Koyama, Nobuhiko Sugano, Yuichi Tamura, S. Yonenobu, Yasuyuki Momoi
MICCAI (2)4
2004 Improvement of depth position in 2-D/3-D registration of knee implants using single-plane fluoroscopy
abstract
Two-dimensional (2-D)/three-dimensional (3-D) registration techniques using single-plane fluoroscopy are highly important for analyzing 3-D kinematics in applications such as total knee arthroplasty (TKA) implants. The accuracy of single-plane fluoroscopy-based techniques in the determination of translation perpendicular to the image plane (depth position), however, is relatively poor because a change in the depth position causes only small changes in the 2-D silhouette. Accuracies achieved in depth position using conventional 2-D/3-D registration techniques are insufficient for clinical applications. Therefore, we propose a technique for improving the accuracy of depth position determination in order to develop a system for analyzing knee kinematics over the full six degrees of freedom (6 DOF) using single-plane fluoroscopy. In preliminary experiments, the behaviors of errors for each free variable were quantified as evaluation curves by examining changes in cost function with variations in the free variable. The evaluation curve for depth position was more jagged, and the curve peak less pointy, compared to the evaluation curves of the other five variables, and the curve was found to behave differently. Depth position is therefore optimized independently of the other variables, using an approximate evaluation curve of depth position prepared after initial registration. Accuracy of the proposed technique was evaluated by computer simulation and in vitro tests, with validation of absolute position and orientation performed for each knee component. In computer simulation tests, root-mean-square error (RMSE) in depth position was improved from 2.6 mm (conventional) to 0.9 mm (proposed), whereas for in vitro tests, RMSE improved from 3.2 mm to 1.4 mm. Accuracy of the estimation of the remaining two translational and three rotational variables was found to be almost the same as that obtained by conventional techniques. Results of in vivo tests are also described in which the possibility of full 6 DOF kinematic analysis of TKA implants is shown.
Takaharu Yamazaki, Tetsu Watanabe, Yoshikazu Nakajima, Kazuomi Sugamoto, Tetsuya Tomita, Hideki Yoshikawa, Shinichi Tamura
IEEE Trans. Medical Imaging3
2003 Camera Model and Calibration Procedure for Oblique-Viewing Endoscope
Tetsuzo Yamaguchi, Masahiko Nakamoto, Yoshinobu Sato, Yoshikazu Nakajima, Kozo Konishi, Makoto Hashizume, Takashi Nishii, Nobuhiko Sugano, Hideki Yoshikawa, Kazuo Yonenobu, Shinichi Tamura
MICCAI (2)4
2003 Physics-based flow estimation of fluids
Yoshikazu Nakajima, Hiroshi Inomata, Hiroki Nogawa, Yoshinobu Sato, Shinichi Tamura, Kozo Okazaki, Seiji Torii
Pattern Recognit.1
2002 Preoperative Analysis of Optimal Imaging Orientation in Fluoroscopy for Voxel-Based 2-D/3-D Registration
Yoshikazu Nakajima, Yuichi Tamura, Yoshinobu Sato, Takahito Tashiro, Nobuhiko Sugano, Kazuo Yonenobu, Hideki Yoshikawa, Takahiro Ochi, Shinichi Tamura
MICCAI (2)1
2002 3D Ultrasound System Using a Magneto-optic Hybrid Tracker for Augmented Reality Visualization in Laparoscopic Liver Surgery
Masahiko Nakamoto, Yoshinobu Sato, Masaki Miyamoto, Yoshikazu Nakajima, Kozo Konishi, Mitsuo Shimada, Makoto Hashizume, Shinichi Tamura
MICCAI (2)4
2002 A Novel Laser Guidance System for Alignment of Linear Surgical Tools: Its Principles and Performance Evaluation as a Man-Machine System
Toshihiko Sasama, Nobuhiko Sugano, Yoshinobu Sato, Yasuyuki Momoi, Tsuyoshi Koyama, Yoshikazu Nakajima, Ichiro Sakuma, Masakatsu G. Fujie, Kazuo Yonenobu, Takahiro Ochi, Shinichi Tamura
MICCAI (2)6
2001 Accuracy Validation of Cone-Beam CT Based Registration
Yoshikazu Nakajima, Toshihiko Sasama, Yoshinobu Sato, Takashi Nishii, Nobuhiko Sugano, Takashi Ishikawa, Kazuo Yonenobu, Takahiro Ochi, Shinichi Tamura
MICCAI1
2001 3D Ultrasound Image Acquisition Using a Magneto-optic Hybrid Sensor for Laparoscopic Surgery
Yoshinobu Sato, Masaki Miyamoto, Masahiko Nakamoto, Yoshikazu Nakajima, Mitsuo Shimada, Makoto Hashizume, Shinichi Tamura
MICCAI4
1998 Image guidance of breast cancer surgery using 3D ultrasonic images and augmented reality visualization
abstract
This paper describes augmented reality visualization for the guidance of breast-conservative cancer surgery using ultrasonic images acquired in the operating room just before surgical resection. By combining an optical three-dimensional (3-D) position sensor, the position and orientation of each ultrasonic cross section are precisely measured to reconstruct geometrically accurate 3-D tumor models from the acquired ultrasonic images. Similarly, the 3-D position and orientation of a video camera are obtained to integrate video and ultrasonic images in a geometrically accurate manner. Superimposing the 3-D tumor models onto live video images of the patient's breast enables the surgeon to perceive the exact 3-D position of the tumor, including irregular cancer invasions which cannot be perceived by touch, as if it were visible through the breast skin. Using the resultant visualization, the surgeon can determine the region for surgical resection in a more objective and accurate manner, thereby minimizing the risk of a relapse and maximizing breast conservation. The system was shown to be effective in experiments using phantom and clinical data.
Yoshinobu Sato, Masahiko Nakamoto, Toshihiko Sasama, Yasuhiro Tamaki, I. Sakita, Yoshikazu Nakajima, Shinichi Tamura, Morito Monden
IEEE Trans. Medical Imaging6
1997 Acquisition of Symbolic Description from Flow Fields: A New Approach Based on a Fluid Model
abstract
We propose a new model and new algorithm for acquiring symbolic description from a flow field. Our model is derived from physical data, and our algorithm is based on holomorphic complex function theory. Application of this method enables both qualitative and quantitative information to be obtained from a flow field. We also demonstrate the robustness of our method using a simulated flow field and a real image sequence.
Hiroki Nogawa, Yoshikazu Nakajima, Yoshinobu Sato, Shinichi Tamura
IEEE Trans. Pattern Anal. Mach. Intell.2