Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Paul M. Novotny

dblp:70/4138 · DBLP profile ↗
← Back
8ranked-venue papers
5as first author
0since 2021 · last 2008
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 5 · 2 first-authorSystems, architecture and hardware · 5 · 2 first-authorApplied, interdisciplinary, general and emerging computing · 3 · 3 first-authorGraphics, computer vision, multimedia, augmented reality and games · 2 · 2 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
4 papers
Motion planning and robot control · 32% Robot manipulation · 29% Autonomous driving · 29%
Interdisciplinary, comprehensive, and emerging computing
2 papers
Medical and health informatics · 100%

Topics — the 10 heaviest of 10, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation › medical robotics
surgical robotics
0.112008
Quasiperiodic predictive filtering for robot-assisted beating heart surgery · ICRA 2008
Robotics › Autonomous driving
trajectory prediction
0.112008
Quasiperiodic predictive filtering for robot-assisted beating heart surgery · ICRA 2008
Robotics › Motion planning and robot control › robot control › sensor-based control
visual servoing
0.112007
Real-Time Visual Servoing of a Robot Using Three-Dimensional Ultrasound · ICRA 2007
Medical and health informatics › medical imaging › ultrasound imaging
3d ultrasound
0.112006
Real-time 3D Ultrasound-based Servoing of a Surgical Instrument · ICRA 2006
Medical and health informatics
medical imaging
0.112006
Real-time 3D Ultrasound-based Servoing of a Surgical Instrument · ICRA 2006
Medical and health informatics
medical robotics
0.112006
Real-time 3D Ultrasound-based Servoing of a Surgical Instrument · ICRA 2006
Computer vision › 3D vision
range sensing
0.011999
Using Infrared Sensors and the Phong Illumination Model to Measure Distances · ICRA 1999
Medical and health informatics
surgical robotics
0.012007
Real-Time Visual Servoing of a Robot Using Three-Dimensional Ultrasound · ICRA 2007
Robotics › Motion planning and robot control
robot control
0.012006
Real-time 3D Ultrasound-based Servoing of a Surgical Instrument · ICRA 2006
Robotics › Robot navigation and mapping
sensor fusion
0.011999
Using Infrared Sensors and the Phong Illumination Model to Measure Distances · ICRA 1999

Methods — techniques the papers use, named apart from their topics

image-based tracking · 0.1GPU-accelerated tracking · 0.1passive instrument marker · 0.1line detection · 0.1image processing · 0.1extended kalman filter · 0.1cardiac motion model · 0.1sonar sensing · 0.0phong illumination model · 0.0
YearPublicationVenuePosition
2008 Quasiperiodic predictive filtering for robot-assisted beating heart surgery
abstract
Beating heart procedures promise significant health benefits to patients but the fast motion of the heart poses a serious challenge to the surgeon. Robotic motion synchronization to heart movements could facilitate these surgeries, although for intracardiac procedures this requires the development of a predictive filter to compensate for the measurement noise and time delay present in 3D ultrasound imaging. In this paper, we present a quasiperiodic cardiac motion model and apply the extended Kalman filter to estimation of its parameters in real-time. We experimentally demonstrate high accuracy robot tracking to heart motion using this filter.
Shelten G. Yuen, Paul M. Novotny, Robert D. Howe
ICRA2
2007 Real-Time Visual Servoing of a Robot Using Three-Dimensional Ultrasound
abstract
This paper presents a robotic system capable of using three-dimensional ultrasound to guide a surgical instrument to a tracked target location. Tracking of both the surgical instrument and target was done using image based algorithms on the real-time 3D ultrasound data. The tracking techniques are shown to be especially amenable for execution on powerful graphics processor units. By harnessing a graphics card, it was possible to detect both a surgical instrument and a surgical target at a rate of 25 Hz. The high update rate permits the use of tracked instrument and target locations for controlling a robot. Validation of the system was done in a water tank, where the robot moved the instrument to the target site with a mean error of 1.2 mm
Paul M. Novotny, Jeffrey A. Stoll, Pierre E. Dupont, Robert D. Howe
ICRA1
2007 An active motion compensation instrument for beating heart mitral valve surgery
abstract
New 3D ultrasound visualization has enabled minimally invasive, beating-heart intracardiac procedures. However, rapid motion of internal heart structures limits the realization of these new procedures. This paper investigates the concept of using a single actuator to compensate for tissue motions which occur largely in one direction. We characterize mitral valve annulus motion and show that it is well approximated by a ID model. The subsequent development of a motion-compensating tool (MCT) is described. The resulting instrument was tested in user trials under a series of positional error and tracking delay conditions. Results indicate that the MCT provides an approximately 50% increase in dexterity and 50% decrease in applied force in comparison to a solid tool. The study also shows that MCT tracking efficacy is highly dependent on tracking delays, indicating the importance of predictive, cyclical control algorithms.
Daniel T. Kettler, Richard D. Plowes, Paul M. Novotny, Nikolay V. Vasilyev, Pedro J. del Nido, Robert D. Howe
IROS3
2007 GPU based real-time instrument tracking with three-dimensional ultrasound
Paul M. Novotny, Jeffrey A. Stoll, Nikolay V. Vasilyev, Pedro J. del Nido, Pierre E. Dupont, Todd E. Zickler, Robert D. Howe
Medical Image Anal.1
2006 Real-time 3D Ultrasound-based Servoing of a Surgical Instrument
abstract
This paper presents a real-time 3D ultrasoundguided robotic system, designed to autonomously navigate a surgical instrument to surgeon-specified target points. The system tracks the instrument in real-time (2 Hz) using image processing. Thus, it does not require tracking of the ultrasound scan head. It makes use of a line detection algorithm and a passive instrument marker, which together report the instrument's position and orientation (6 d.o.f.) from a single ultrasound image. Validation experiments are presented. The system controlled instrument position in a variety of image locations with a mean error of 0.8 mm
Jeffrey A. Stoll, Paul M. Novotny, Robert D. Howe, Pierre E. Dupont
ICRA2
2006 GPU Based Real-Time Instrument Tracking with Three Dimensional Ultrasound
Paul M. Novotny, Jeffrey A. Stoll, Nikolay V. Vasilyev, Pedro J. del Nido, Pierre E. Dupont, Robert D. Howe
MICCAI (1)1
2003 Tool Localization in 3D Ultrasound Images
Paul M. Novotny, Jeremy W. Cannon, Robert D. Howe
MICCAI (2)1
1999 Using Infrared Sensors and the Phong Illumination Model to Measure Distances
abstract
Currently, the viability of infrared (IR) as an accurate means of measuring distance depends on extensive prior knowledge of the surface. More specifically, the manner in which a surface scatters, reflects, and absorbs infrared energy is needed to interpret the sensor output as a distance measure. In order to use IR in an unknown environment, one must determine the surface properties during robot operation. The paper details a method of determining the properties of a surface, vis-a-vis infrared reflectance, and subsequently calculating the distance to the surface and the relative orientation of the surface using previously acquired sensory data. We present examples of IR distance measures for various surfaces using known environments as well as examples where the prior knowledge edge has been acquired using sonar sensing. Our results demonstrate that infrared sensors can provide accurate range measurements when used in conjunction with other sensing modalities to fit model parameters during robot operation (i.e. in real-time).
Paul M. Novotny, Nicola J. Ferrier
ICRA1