Demo Data from SIGIR 2026 / reviewers in the wild / expert
Kyle N. Winfree
dblp:77/7809
· DBLP profile ↗
4ranked-venue papers
2as first author
0since 2021 · last 2018
0000-0002-3552-4803ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 2 · 1 first-authorSystems, architecture and hardware · 2 · 1 first-authorApplied, interdisciplinary, general and emerging computing · 2 · 1 first-author
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Human-computer interaction and pervasive computing
3 papers |
Health and well-being technologies · 67% Haptics and multimodal interaction · 24% Human-robot interaction · 9% | |
| Artificial intelligence
1 paper |
Robot manipulation · 100% |
Topics — the 2 heaviest of 4, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Health and well-being technologies › rehabilitation technology
rehabilitation robotics |
0.3 | 2 | 2013 | Rehabilitation Exoskeleton Design: Exploring the Effect of the Anterior Lunge Degree of Freedom · IEEE Trans. Robotics 2013 Degrees-of-freedom of a robotic exoskeleton and human adaptation to new gait templates · ICRA 2012 |
Robotics › Robot manipulation › wearable robotics › exoskeleton
exoskeleton design |
0.0 | 1 | 2013 | Rehabilitation Exoskeleton Design: Exploring the Effect of the Anterior Lunge Degree of Freedom · IEEE Trans. Robotics 2013 |
Methods — techniques the papers use, named apart from their topics
human-subject experiment · 0.2human subject experiment · 0.2degrees-of-freedom analysis · 0.1position-p-at-time-t commands · 0.1packet-based control · 0.1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2018 | Modeling Clinically Validated Physical Activity Assessments Using Commodity HardwareabstractConsumer-grade wearable activity devices such as Fitbits are increasingly being used in research settings to promote physical activity (PA) due to their low-cost and widespread popularity. However, Fitbit-derived measures of activity intensity are consistently reported to be less accurate than intensity estimates obtained from research-grade accelerometers (i.e., ActiGraph). As such, the potential for using a Fitbit to measure PA intensity within research contexts remains limited. This study aims to model ActiGraph-based intensity estimates from the validated Freedson vector magnitude (VM3) algorithm using measures of steps, metabolic equivalents, and intensity levels obtained from Fitbit. Minute-level data collected from 19 subjects, who concurrently wore the ActiGraph GT3X and Fitbit Flex devices for an average of 1.8 weeks, were used to generate the model. After testing several modeling methods, a naïve Bayes classifier was chosen based on the lowest achieved error rate. Overall, the model reduced Fitbit to ActiGraph errors from 19.97% to 16.32%. Moreover, the model reduced misclassification of Fitbit-based estimates of moderate-to-vigorous physical activity (MVPA) by 40%, eliminating a statistically significant difference between MVPA estimates derived from ActiGraph and Fitbit. Study findings support the general utility of the model for measuring MVPA with the Fitbit Flex in place of the more costly ActiGraph GT3X accelerometer for young healthy adults. Kyle N. Winfree, Gregory Dominick |
IEEE J. Biomed. Health Informatics | 1 |
| 2013 | Rehabilitation Exoskeleton Design: Exploring the Effect of the Anterior Lunge Degree of FreedomabstractAs our robotics community advances its understanding toward the optimal design of robotic exoskeletons for human gait training, the question we ask in this paper is how the anterior lunge degree of freedom in the robotic exoskeleton affects human gait training. Answering this question requires both novel robotic design and novel protocols for human gait training to characterize this effect. To the best of the authors' knowledge, this is the first study to characterize the effect of an exoskeleton's degrees of freedom on human gait adaptation. We explored this question using the Active Leg EXoskeleton (ALEX) II. The study presented was performed using ALEX II under the following two configurations: 1) locking the anterior/posterior translation in the exoskeleton, while allowing other degrees-of-freedom (labeled as locked mode) and 2) keeping the anterior/posterior degree of freedom unlocked (labeled as unlocked mode). Healthy subjects walked at self-selected speeds on a treadmill and were trained to walk with a new gait template, scaled down from their normal template. While both groups showed adaptation and retention over a 26-min period following training, the unlocked group showed better performance in terms of adaptation and retention compared with the locked group. Paul Stegall, Kyle N. Winfree, Damiano Zanotto, Sunil K. Agrawal |
IEEE Trans. Robotics | 2 |
| 2012 | Degrees-of-freedom of a robotic exoskeleton and human adaptation to new gait templatesabstractThis paper addresses an important question in the field of rehabilitation robotics that can help engineers to develop and optimize future gait training robotic exoskeletons. This question can be posed as follows: Do the exoskeleton's degrees-of-freedom at the pelvis affect human adaptation to new gait templates? More specifically, would additional degrees-of-freedom in the exoskeleton that allow the human trunk to translate and rotate, and the hips to abduct/adduct increase human gait adaptation with an exoskeleton? Paul Stegall, Kyle N. Winfree, Sunil K. Agrawal |
ICRA | 2 |
| 2010 | Control of a high fidelity ungrounded torque feedback device: The iTorqU 2.1abstractThis paper outlines how a control moment gyroscope can be used to generate haptic torque feedback while minimizing the effects of a constrained gimbal workspace. We present the design of the iTorqU 2.1 and discuss how it compares to previously developed systems. We then detail the control algorithms we have developed for both transparency and torque output modes. The prescribed transparency controller is typical in design, but the torque output algorithm is novel to this type of haptic device. It makes use of a series of position-p-at-time-t commands, which we call packets. Five packet designs were considered in this research, but we have included only the most important three in this paper. While this research deals with torque feedback, it ultimately presents a method for working with devices that are limited by the need for continuous reset to a home position before subsequent outputs. Kyle N. Winfree, Joseph M. Romano, Jamie Gewirtz, Katherine J. Kuchenbecker |
ICRA | 1 |