Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Csaba Csoma

dblp:81/414 · DBLP profile ↗
← Back
5ranked-venue papers
0as first author
0since 2021 · last 2008
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Graphics, computer vision, multimedia, augmented reality and games · 3Applied, interdisciplinary, general and emerging computing · 3Artificial intelligence and machine learning · 2Systems, architecture and hardware · 2

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
2 papers
Robot manipulation · 72% Robot navigation and mapping · 22% Motion planning and robot control · 6%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%
Human-computer interaction and pervasive computing
1 paper
Health and well-being technologies · 100%

Topics — the 5 heaviest of 7, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation
medical robotics
0.222008
Integrated system for robot-assisted in prostate biopsy in closed MRI scanner · ICRA 2008
Pneumatically operated MRI-compatible needle placement robot for prostate interventions · ICRA 2008
Robotics › Robot manipulation › medical robotics
robotic biopsy
0.112008
Integrated system for robot-assisted in prostate biopsy in closed MRI scanner · ICRA 2008
Medical and health informatics
image-guided intervention
0.112008
Pneumatically operated MRI-compatible needle placement robot for prostate interventions · ICRA 2008
Robotics › Robot manipulation › actuator design
pneumatic actuation
0.012008
Pneumatically operated MRI-compatible needle placement robot for prostate interventions · ICRA 2008
Robotics › Motion planning and robot control
robot control
0.012008
Pneumatically operated MRI-compatible needle placement robot for prostate interventions · ICRA 2008

Methods — techniques the papers use, named apart from their topics

transperineal needle insertion · 0.2pneumatic actuation · 0.2magnetic resonance imaging · 0.2intra-operative MRI · 0.2
YearPublicationVenuePosition
2008 Pneumatically operated MRI-compatible needle placement robot for prostate interventions
abstract
Magnetic Resonance Imaging (MRI) has potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. The strong magnetic field prevents the use of conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intra-prostatic needle placement inside closed high-field MRI scanners. The robot performs needle insertion under real-time 3T MR image guidance; workspace requirements, MR compatibility, and workflow have been evaluated on phantoms. The paper explains the robot mechanism and controller design and presents results of preliminary evaluation of the system.
Gregory S. Fischer, Iulian Iordachita, Csaba Csoma, Junichi Tokuda, Philip Walter Mewes, Clare M. Tempany, Nobuhiko Hata, Gabor Fichtinger
ICRA3
2008 Integrated system for robot-assisted in prostate biopsy in closed MRI scanner
abstract
Prostate cancer biopsy is a routine medical procedure, yet conventional techniques suffer from low sensitivity attributed to suboptimal image guidance and needle placement. Targeting small lesions and foci (5 mm in diameter) is particularly prone to errors. We developed an integrated system to perform robot-assisted transperineal needle insertions into the prostate, under Magnetic Resonance Imaging (MRI) guidance. The system provides arbitrary needle trajectories and allows for simultaneous surveillance and correction of the needle path, based on intra-operative MRI. System functionality and data transfer and processing tests were conducted. Five lesions embedded in the gel phantom were targeted successfully, while communication delays (due to higher image frame rates) had no adverse affect on robot-software communication. The system was sufficiently resistant to high network loads and performed with an acceptable transfer rate.
Philip Walter Mewes, Junichi Tokuda, Simon P. DiMaio, Gregory S. Fischer, Csaba Csoma, David G. Gobbi, Clare M. Tempany, Gabor Fichtinger, Nobuhiko Hata
ICRA5
2008 MRI Compatibility of Robot Actuation Techniques - A Comparative Study
Gregory S. Fischer, Axel Krieger, Iulian Iordachita, Csaba Csoma, Louis L. Whitcomb, Gabor Fichtinger
MICCAI (2)4
2008 Software Strategy for Robotic Transperineal Prostate Therapy in Closed-Bore MRI
Junichi Tokuda, Gregory S. Fischer, Csaba Csoma, Simon P. DiMaio, David G. Gobbi, Gabor Fichtinger, Clare M. Tempany, Nobuhiko Hata
MICCAI (2)3
2007 Design and Preliminary Accuracy Studies of an MRI-Guided Transrectal Prostate Intervention System
Axel Krieger, Csaba Csoma, Iulian Iordachita, Peter Guion, Anurag K. Singh, Gabor Fichtinger, Louis L. Whitcomb
MICCAI (2)2