Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

James Handa

dblp:84/866 · also James T. Handa · DBLP profile ↗
← Back
13ranked-venue papers
0as first author
0since 2021 · last 2014
0000-0003-1314-1745ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 7Systems, architecture and hardware · 7Graphics, computer vision, multimedia, augmented reality and games · 5Applied, interdisciplinary, general and emerging computing · 5Human-computer interaction and ubiquitous computing · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
4 papers
Medical and health informatics · 100%
Artificial intelligence
3 papers
Robot manipulation · 100%

Topics — the 4 heaviest of 5, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics
surgical robotics
0.422014
A multi-function force sensing instrument for variable admittance robot control in retinal microsurgery · ICRA 2014
A novel dual force sensing instrument with cooperative robotic assistant for vitreoretinal surgery · ICRA 2013
Robotics › Robot manipulation
force sensing
0.332014
Towards robot-assisted vitreoretinal surgery: Force-sensing micro-forceps integrated with a handheld micromanipulator · ICRA 2014
Development and preliminary data of novel integrated optical micro-force sensing tools for retinal microsurgery · ICRA 2009
A comparative study for robot assisted vitreoretinal surgery: Micron vs. the Steady-Hand Robot · ICRA 2013
Medical and health informatics › surgical robotics
robot-assisted surgery
0.222014
A comparative study for robot assisted vitreoretinal surgery: Micron vs. the Steady-Hand Robot · ICRA 2013
Towards robot-assisted vitreoretinal surgery: Force-sensing micro-forceps integrated with a handheld micromanipulator · ICRA 2014
Medical and health informatics › ophthalmology
vitreoretinal surgery
0.222014
A comparative study for robot assisted vitreoretinal surgery: Micron vs. the Steady-Hand Robot · ICRA 2013
Towards robot-assisted vitreoretinal surgery: Force-sensing micro-forceps integrated with a handheld micromanipulator · ICRA 2014

Methods — techniques the papers use, named apart from their topics

force sensing · 0.7tremor cancellation · 0.4fiber bragg grating sensing · 0.4comparative evaluation · 0.3fiber bragg grating strain sensing · 0.2
YearPublicationVenuePosition
2014 Towards robot-assisted vitreoretinal surgery: Force-sensing micro-forceps integrated with a handheld micromanipulator
abstract
In vitreoretinal practice, controlled tremor-free motion and limitation of applied forces to the retina are two highly desired features. This study addresses both requirements with a new integrated system: a force-sensing motorized micro-forceps combined with an active tremor-canceling handheld micromanipulator, known as Micron. The micro-forceps is a 20 Ga instrument that is mechanically decoupled from its handle and senses the transverse forces at its tip with an accuracy of 0.3 mN. Membrane peeling trials on a bandage phantom revealed a 60-95% reduction in the 2-20 Hz band in both the tip force and position spectra, while peeling forces remained below the set safety threshold.
Berk Gonenc, Ellen Feldman, Peter Gehlbach, James Handa, Russell H. Taylor, Iulian Iordachita
ICRA4
2014 A multi-function force sensing instrument for variable admittance robot control in retinal microsurgery
abstract
Robotic systems have the potential to assist vitreoretinal surgeons in extremely difficult surgical tasks inside the human eye. In addition to reducing hand tremor and improving tool positioning, a robotic assistant can provide assistive motion guidance using virtual fixtures, and incorporate real-time feedback from intraocular force sensing ophthalmic instruments to present tissue manipulation forces, that are otherwise physically imperceptible to the surgeon. This paper presents the design of an FBG-based, multi-function instrument that is capable of measuring mN-level forces at the instrument tip located inside the eye, and also the sclera contact location on the instrument shaft and the corresponding contact force. The given information is used to augment cooperatively controlled robot behavior with variable admittance control. This effectively creates an adaptive remote center-of-motion (RCM) constraint to minimize eye motion, but also allows the translation of the RCM location if the instrument is not near the retina. In addition, it provides force scaling for sclera force feedback. The calibration and validation of the multi-function force sensing instrument are presented, along with demonstration and performance assessment of the variable admittance robot control on an eye phantom.
Xingchi He, Marcin Balicki, Peter Gehlbach, James Handa, Russell H. Taylor, Iulian Iordachita
ICRA4
2013 A comparative study for robot assisted vitreoretinal surgery: Micron vs. the Steady-Hand Robot
abstract
In vitreoretinal surgery, application of excessive forces and unintentional motion due to hand-tremor can easily result in serious complications. Robotic assistance when combined with tool-to-tissue force sensing capabilities has significant potential to improve such practice. In this paper, we evaluate the membrane peeling performance of a single user for two distinct robotic systems with integrated force sensing capabilities: Micron and the Steady-Hand Robot. We show that these systems provide promising performance improvement with similar impact on peeling forces and comparable tremor cancellation trends.
Berk Gonenc, James Handa, Peter Gehlbach, Russell H. Taylor, Iulian Iordachita
ICRA2
2013 A novel dual force sensing instrument with cooperative robotic assistant for vitreoretinal surgery
abstract
Robotic assistants and smart surgical instruments have been developed to overcome many significant physiological limitations faced by vitreoretinal surgeons, one of which is lack of force perception below 7.5 mN. This paper reports the development of a new force sensor based on fiber Bragg grating (FBG) with the ability to sense forces at the tip of the surgical instrument located inside the eye and also provide information about instrument interaction with the sclera. The sclera section provides vital feedback for cooperative robot control to minimize potentially dangerous forces on the eye. Preliminary results with 2×2 degree-of-freedom (DOF) sensor and force scaling robot control demonstrate significant reduction of forces on the sclera. The design and analysis of the sensor is presented along with a simulated robot assisted retinal membrane peeling on a phantom with sclera constraints and audio feedback.
Xingchi He, Marcin Balicki, Peter Gehlbach, James Handa, Russell H. Taylor, Iulian Iordachita
ICRA4
2013 Comparison of Baseline Tremor under Various Microsurgical Conditions
abstract
This paper presents the characterization and comparison of physiological tremor for pointing tasks in multiple environments, as a baseline for performance evaluation of microsurgical robotics. Previous studies have examined the characteristics of physiological tremor under laboratory settings as well as different operating conditions. However, different test methods make the comparison of results across trials and conditions difficult. Two vitroretinal microsurgeons were evaluated while performing a pointing task with no entry-point constraint, constrained by an artificial eye model, and constrained by a rabbit eye in vivo. For the three respective conditions the 3D RMS positioning error was 144 μm, 258 μm, and 285 μm, and maximum 3D error was 349 μm, 647 μm, and 696 μm. A spectral analysis was also performed, confirming a distinct peak near in the 6-12 Hz frequency range, characteristic of hand tremor during tasks in all three environments.
Trent S. Wells, Sungwook Yang, Robert A. MacLachlan, James Handa, Peter Gehlbach, Cameron N. Riviere
SMC4
2012 Preliminary evaluation of a micro-force sensing handheld robot for vitreoretinal surgery
abstract
Highly accurate positioning is fundamental to the performance of vitreoretinal microsurgery. Of vitreoretinal procedures, membrane peeling is among the most prone to complications since extremely delicate manipulation of retinal tissue is required. Associated tool-to-tissue interaction forces are usually below the threshold of human perception, and the surgical tools are moved very slowly, within the 0.1-0.5 mm/s range. During the procedure, unintentional tool motion and excessive forces can easily give rise to vision loss or irreversible damage to the retina. A successful surgery includes two key features: controlled tremor-free tool motion and control of applied force. In this study, we present the potential benefits of a micro-force sensing robot in vitreoretinal surgery. Our main contribution is implementing fiber Bragg grating based force sensing in an active tremor canceling handheld micromanipulator, known as Micron, to measure tool-to-tissue interaction forces in real time. Implemented auditory sensory substitution assists in reducing and limiting forces. In order to test the functionality and performance, the force sensing Micron was evaluated in peeling experiments with adhesive bandages and with the inner shell membrane from chicken eggs. Our findings show that the combination of active tremor canceling together with auditory sensory substitution is the most promising aid that keeps peeling forces below 7 mN with a significant reduction in 2-20 Hz oscillations.
Berk Gonenc, Marcin Balicki, James Handa, Peter Gehlbach, Cameron N. Riviere, Russell H. Taylor, Iulian Iordachita
IROS3
2010 Micro-force Sensing in Robot Assisted Membrane Peeling for Vitreoretinal Surgery
Marcin Balicki, Ali Uneri, Iulian Iordachita, James Handa, Peter Gehlbach, Russell H. Taylor
MICCAI (3)4
2010 Adaptive Multispectral Illumination for Retinal Microsurgery
Raphael Sznitman, Diego Rother, James Handa, Peter Gehlbach, Gregory D. Hager, Russell H. Taylor
MICCAI (3)3
2009 Development and preliminary data of novel integrated optical micro-force sensing tools for retinal microsurgery
abstract
This paper reports the development of novel micro-force sensing tools for retinal microsurgery. Retinal microsurgery requires extremely delicate manipulation of retinal tissue, and tool-to-tissue interaction forces are frequently below human perceptual thresholds. Further, the interaction between the tool shaft and sclera makes accurate sensing of forces exerted on the retina very difficult with previously developed force sensing schemes, in which the sensor is located outside the eye. In the work reported here, we incorporate 160 µm Fiber Bragg Grating (FBG) strain sensors into the tool shaft to sense forces distal to the sclera. The sensor is applicable both with robotically manipulated and freehand tools. Preliminary results with a 1 degree-of-freedom (DOF) sensor have demonstrated 0.25 mN resolution, and work is underway to develop 2 and 3 DOF tools. The design and analysis of the force sensing tool is presented with preliminary testing data and some initial experiments using the tool with both freehand and robotic manipulation.
Zhenglong Sun 0001, Marcin Balicki, Jin U. Kang, James Handa, Russell H. Taylor, Iulian Iordachita
ICRA4
2009 Single Fiber Optical Coherence Tomography Microsurgical Instruments for Computer and Robot-Assisted Retinal Surgery
Marcin Balicki, Jae-Ho Han, Iulian Iordachita, Peter Gehlbach, James Handa, Russell H. Taylor, Jin U. Kang
MICCAI (1)5
2008 Cooperative Robot Assistant for Retinal Microsurgery
Ioana Fleming, Marcin Balicki, John Koo, Iulian Iordachita, Ben Mitchell, James Handa, Gregory D. Hager, Russell H. Taylor
MICCAI (2)6
2008 Intraoperative Visualization of Anatomical Targets in Retinal Surgery
abstract
Certain surgical procedures require a high degree of precise manual control within a very restricted area. Retinal surgeries are part of this group of procedures. During vitreoretinal surgery, the surgeon must visualize, using a microscope, an area spanning a few hundreds of microns in diameter and manually correct the potential pathology using direct contact, free hand techniques. In addition, the surgeon must find an effective compromise between magnification, depth perception, field of view, and clarity of view. Pre-operative images are used to locate interventional targets, and also to assess and plan the surgical procedure. This paper proposes a method of fusing information contained in pre-operative imagery, such as fundus and OCT images, with intra-operative video to increase accuracy in finding the target areas. We describe methods for maintaining, in real-time, registration with anatomical features and target areas using image processing. This registration allows us to produce information enhanced displays that ensure that the retinal surgeon is always in visual contact with his/her area of interest.
Ioana Fleming, Sandrine Voros, Balázs Vágvölgyi, Zachary A. Pezzementi, James Handa, Russell H. Taylor, Gregory D. Hager
WACV5
2007 Development and Application of a New Steady-Hand Manipulator for Retinal Surgery
abstract
This paper describes the development and initial testing of a new and optimized version of a steady-hand manipulator for retinal microsurgery. In the steady-hand paradigm, the surgeon and the robot share control of a tool attached to the robot through a force sensor. The robot controller senses forces exerted by the operator on the tool and uses this information in various control modes to provide smooth, tremor-free, precise positional control and force scaling. The steady-hand manipulator reported here has been specifically designed with the unique constraints of retinal microsurgery in mind. In particular, the system makes use of a compact wrist design that places the bulk of the robot away from the operating field. The resulting system has high efficacy, flexibility and ergonomics while meeting the accuracy and safety requirements of microsurgery. We have now tested this robot on a biological model system and we report a protocol for reliably cannulating ~80 mum OD veins (the size of veins in the human retina) using the system
Ben Mitchell, John Koo, Iulian Iordachita, Peter Kazanzides, Ankur Kapoor, James Handa, Gregory D. Hager, Russell H. Taylor
ICRA6