Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Samuel Victor Lichtenstein

dblp:86/4744 · DBLP profile ↗
← Back
3ranked-venue papers
0as first author
0since 2021 · last 2015
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 2Systems, architecture and hardware · 2Graphics, computer vision, multimedia, augmented reality and games · 1Applied, interdisciplinary, general and emerging computing · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
2 papers
Robot manipulation · 80% Motion planning and robot control · 20%

Topics — the 3 heaviest of 3, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation › medical robotics
surgical robotics
0.222015
On the feasibility of heart motion compensation on the daVinci® surgical robot for coronary artery bypass surgery: Implementation and user studies · ICRA 2015
Stabilizer and Surgical Arm Design for Cardiac Surgery · ICRA 1998
Robotics › Motion planning and robot control
teleoperation
0.112015
On the feasibility of heart motion compensation on the daVinci® surgical robot for coronary artery bypass surgery: Implementation and user studies · ICRA 2015
Robotics › Robot manipulation › medical robotics
surgical robot arm design
0.011998
Stabilizer and Surgical Arm Design for Cardiac Surgery · ICRA 1998

Methods — techniques the papers use, named apart from their topics

spectral line decomposition · 0.2open-loop control · 0.2kinematic design · 0.0force measurement · 0.0
YearPublicationVenuePosition
2015 On the feasibility of heart motion compensation on the daVinci® surgical robot for coronary artery bypass surgery: Implementation and user studies
abstract
This paper describes the implementation of a heart motion compensation system on the da Vinci surgical system (Intuitive Surgical Inc.) for coronary artery bypass surgery. By introducing a robot-assisted solution, this surgery could be performed completely minimally invasively and on a beating heart. In this work we describe the development of open loop controllers based on spectral line decomposition and the assumption of a periodic trajectory. This allows the da Vinci patient-side manipulators to track an actual heart trajectory with sub-millimetre error. Further, to simulate a virtually stabilized environment, we present the novel concept of maintaining the camera fixed relative to the heart target, effectively decoupling the vision tracking and arm tracking challenges. Finally, we executed preliminary experiments to evaluate surgeons' ability to perform simulated suturing and peg transfer tasks on a moving target. Performance for the simulated suturing was evaluated based on task completion time, accuracy of needle placement, and number of errors. For the suture task, the number of missed targets decreased from 37% to 13% when compensation was enabled, the number of hit targets increased from 26% to 41%, and completion time decreased. For the peg transfer tasks, again completion time and number of errors were measured. Though the margin for error was larger, there was less perceived difficulty of the task when compensation was enabled.
Angelica Ruszkowski, Omid Mohareri, Samuel Victor Lichtenstein, Richard Cook, Tim Salcudean
ICRA3
1999 On the Feasibility of a Moving Support for Surgery on the Beating Heart
Ana Luisa Trejos, Tim Salcudean, Farrokh Sassani, Samuel Victor Lichtenstein
MICCAI4
1998 Stabilizer and Surgical Arm Design for Cardiac Surgery
abstract
Presents the design of a cardiac tissue stabilizing device with fixating surgical arm, developed for open-heart cardiac surgery to stabilize anastomosis sites during off-pump coronary artery bypass grafting surgeries. The stabilization device is a "C"-shaped hollow ring that holds the heart using vacuum pressure. The arm is a seven link, 18-DOF, redundant, passive, serial linkage. As it attaches directly to the patient on the chest retractor, the arm has a stable mechanical ground protecting the patient from injury should they move during surgery. Measured forces and torques from two pigs' hearts were scaled to human magnitudes to determine stabilizer lifting and arm braking requirements.
Terence J. Gilhuly, Tim Salcudean, K. Ashe, Samuel Victor Lichtenstein, Peter D. Lawrence
ICRA4