Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Ruola Ning

dblp:88/858 · DBLP profile ↗
← Back
4ranked-venue papers
1as first author
0since 2021 · last 2005
0000-0003-0578-9197ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 3 · 1 first-authorGraphics, computer vision, multimedia, augmented reality and games · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer graphics and multimedia
1 paper
Image and video processing · 75% Multimedia analysis and retrieval · 25%

Topics — the 4 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Multimedia analysis and retrieval
image analysis
0.112005
Image Denoising Based on Wavelets and Multifractals for Singularity Detection · IEEE Trans. Image Process. 2005
Image and video processing › image restoration
image denoising
0.112005
Image Denoising Based on Wavelets and Multifractals for Singularity Detection · IEEE Trans. Image Process. 2005
Image and video processing
image restoration
0.112005
Image Denoising Based on Wavelets and Multifractals for Singularity Detection · IEEE Trans. Image Process. 2005
Image and video processing
singularity detection
0.112005
Image Denoising Based on Wavelets and Multifractals for Singularity Detection · IEEE Trans. Image Process. 2005

Methods — techniques the papers use, named apart from their topics

wavelet transform · 0.1multifractal analysis · 0.1minimum mean squared error estimation · 0.1fuzzy weighted mean filter · 0.1
YearPublicationVenuePosition
2005 Image Denoising Based on Wavelets and Multifractals for Singularity Detection
abstract
This paper presents a very efficient algorithm for image denoising based on wavelets and multifractals for singularity detection. A challenge of image denoising is how to preserve the edges of an image when reducing noise. By modeling the intensity surface of a noisy image as statistically self-similar multifractal processes and taking advantage of the multiresolution analysis with wavelet transform to exploit the local statistical self-similarity at different scales, the pointwise singularity strength value characterizing the local singularity at each scale was calculated. By thresholding the singularity strength, wavelet coefficients at each scale were classified into two categories: the edge-related and regular wavelet coefficients and the irregular coefficients. The irregular coefficients were denoised using an approximate minimum mean-squared error (MMSE) estimation method, while the edge-related and regular wavelet coefficients were smoothed using the fuzzy weighted mean (FWM) filter aiming at preserving the edges and details when reducing noise. Furthermore, to make the FWM-based filtering more efficient for noise reduction at the lowest decomposition level, the MMSE-based filtering was performed as the first pass of denoising followed by performing the FWM-based filtering. Experimental results demonstrated that this algorithm could achieve both good visual quality and high PSNR for the denoised images.
Junmei Zhong, Ruola Ning
IEEE Trans. Image Process.2
2004 Image denoising based on multiscale singularity detection for cone beam CT breast imaging
abstract
It was recently reported that the real-time flat panel detector-based cone-beam computed tomography (CBCT) breast imaging can help improve the detectability of small breast tumors with an X-ray dose comparable to that of the conventional mammography. In this paper, an efficient denoising algorithm is proposed to further reduce the X-ray exposure level required by a CBCT scan to acquire acceptable image quality. The proposed wavelet-based denoising algorithm possesses three significant characteristics: 1) wavelet coefficients at each scale are classified into two categories: irregular coefficients, and edge-related and regular coefficients; 2) noise in irregular coefficients is reduced as much as possible without producing artifacts to the denoised images; and 3) for the edge-related and regular coefficients, if they are at the first decomposition level, they are further denoised, otherwise, no modifications are made to them so as to obtain good visual quality for diagnosis. By applying the proposed denoising algorithm to the filtered projection images, the X-ray exposure level necessary for the CBCT scan can be reduced by up to 60% while obtaining clinically acceptable image quality. This denoising result indicates that in the clinical application of CBCT breast imaging, the patient radiation dose can be significantly reduced.
Junmei Zhong, Ruola Ning, David Conover
IEEE Trans. Medical Imaging2
2000 Flat Panel Detector-Based Cone Beam Volume CT Angiography Imaging: System Evaluation
abstract
Preliminary evaluation of recently developed large-area flat panel detectors (FPDs) indicates that FPDs have some potential advantages: compactness, absence of geometric distortion and veiling glare with the benefits of high resolution, high detective quantum efficiency (DQE), high frame rate and high dynamic range, small image lag (< 1%), and excellent linearity (approximately 1%). The advantages of the new FPD make it a promising candidate for cone-beam volume computed tomography (CT) angiography (CBVCTA) imaging. The purpose of this study is to characterize a prototype FPD-based imaging system for CBVCTA applications. A prototype FPD-based CBVCTA imaging system has been designed and constructed around a modified GE 8800 CT scanner. This system is evaluated for a CBVCTA imaging task in the head and neck using four phantoms and a frozen rat. The system is first characterized in terms of linearity and dynamic range of the detector. Then, the optimal selection of kVps for CBVCTA is determined and the effect of image lag and scatter on the image quality of the CBVCTA system is evaluated. Next, low-contrast resolution and high-contrast spatial resolution are measured. Finally, the example reconstruction images of a frozen rat are presented. The results indicate that the FPD-based CBVCT can achieve 2.75-lp/mm spatial resolution at 0% modulation transfer function (MTF) and provide more than enough low-contrast resolution for intravenous CBVCTA imaging in the head and neck with clinically acceptable entrance exposure level. The results also suggest that to use an FPD for large cone-angle applications, such as body angiography, further investigations are required.
Ruola Ning, Rongfeng Yu, David Conover, Yi Ning
IEEE Trans. Medical Imaging1
1999 A Cone-Beam Reconstruction Algorithm for Circle-Plus-Arc Data Acquisition Geometry
abstract
In cone-beam computerized tomography (CT), projections acquired with the focal spot constrained on a planar orbit cannot provide a complete set of data to reconstruct the object function exactly. There are severe distortions in the reconstructed noncentral transverse planes when the cone angle is large. In this work, a new method is proposed which can obtain a complete set of data by acquiring cone-beam projections along a circle-plus-arc orbit. A reconstruction algorithm using this circle-plus-arc orbit is developed, based on the Radon transform and Grangeat's formula. This algorithm first transforms the cone-beam projection data of an object to the first derivative of the three-dimensional (3-D) Radon transform, using Grangeat's formula, and then reconstructs the object using the inverse Radon transform. In order to reduce interpolation errors, new rebinning equations have been derived accurately, which allows one-dimensional (1-D) interpolation to be used in the rebinning process instead of 3-D interpolation. A noise-free Defrise phantom and a Poisson noise-added Shepp-Logan phantom were simulated and reconstructed for algorithm validation. The results from the computer simulation indicate that the new cone-beam data-acquisition scheme can provide a complete set of projection data and the image reconstruction algorithm can achieve exact reconstruction. Potentially, the algorithm can be applied in practice for both a standard CT gantry-based volume tomographic imaging system and a C-arm-based cone-beam tomographic imaging system, with little mechanical modification required.
Ruola Ning
IEEE Trans. Medical Imaging2