Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Gregory A. Cole

dblp:88/9962 · DBLP profile ↗
← Back
3ranked-venue papers
1as first author
0since 2021 · last 2012
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 3 · 1 first-authorSystems, architecture and hardware · 3 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
2 papers
Robot manipulation · 72% Motion planning and robot control · 28%
Interdisciplinary, comprehensive, and emerging computing
2 papers
Medical and health informatics · 100%

Topics — the 8 heaviest of 8, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation › medical robotics
needle steering
0.112011
Real-time MRI-guided needle placement robot with integrated fiber optic force sensing · ICRA 2011
Robotics › Motion planning and robot control
robot control
0.112011
Real-time MRI-guided needle placement robot with integrated fiber optic force sensing · ICRA 2011
Robotics › Robot manipulation › medical robotics
MRI-compatible robot
0.112009
Design of a robotic system for MRI-guided deep brain stimulation electrode placement · ICRA 2009
Robotics › Robot manipulation
robot design
0.112009
Design of a robotic system for MRI-guided deep brain stimulation electrode placement · ICRA 2009
Medical and health informatics
computer-assisted surgery
0.112009
Design of a robotic system for MRI-guided deep brain stimulation electrode placement · ICRA 2009
Medical and health informatics › image-guided intervention
MRI-guided intervention
0.112009
Design of a robotic system for MRI-guided deep brain stimulation electrode placement · ICRA 2009
Medical and health informatics
surgical robotics
0.112009
Design of a robotic system for MRI-guided deep brain stimulation electrode placement · ICRA 2009
Medical and health informatics › medical robotics
robot-assisted intervention
0.012011
Real-time MRI-guided needle placement robot with integrated fiber optic force sensing · ICRA 2011

Methods — techniques the papers use, named apart from their topics

piezoelectric actuation · 0.2fiber optic force sensing · 0.2fabry-perot interferometer · 0.2workspace analysis · 0.2mechanism design · 0.2MR compatibility evaluation · 0.2
YearPublicationVenuePosition
2012 A MRI-guided concentric tube continuum robot with piezoelectric actuation: A feasibility study
abstract
This paper presents a versatile magnetic resonance imaging (MRI) compatible concentric tube continuum robotic system. The system enables MR image-guided placement of a curved, steerable active cannula. It is suitable for a variety of clinical applications including image-guided neurosurgery and percutaneous interventions, along with procedures that involve accessing a desired image target, through a curved trajectory. This 6 degree-of-freedom (DOF) robotic device is piezoelectrically actuated to provide precision motion with joint-level precision of better than 0.03mm, and is fully MRI-compatible allowing simultaneous robotic motion and imaging with no image quality degradation. The MRI compatibility of the robot has been evaluated under 3 Tesla MRI using standard prostate imaging sequences, with an average signal to noise ratio loss of less than 2% during actuator motion. The accuracy of active cannula control was evaluated in benchtop trials using an external optical tracking system with RMS error in tip placement of 1.00mm. Preliminary phantom trials of three active cannula placements in the MRI scanner showed cannula trajectories that agree with our kinematic model, with a RMS tip placement error of 0.61 - 2.24 mm.
Hao Su 0002, Diana C. Cardona, Weijian Shang, Alexander Camilo, Gregory A. Cole, D. Caleb Rucker, Robert J. Webster III, Gregory S. Fischer
ICRA5
2011 Real-time MRI-guided needle placement robot with integrated fiber optic force sensing
abstract
This paper presents the first prototype of a magnetic resonance imaging (MRI) compatible piezoelectric actuated robot integrated with a high-resolution fiber optic sensor for prostate brachytherapy with real-time in situ needle steering capability in 3T MRI. The 6-degrees-of-freedom (DOF) robot consists of a modular 3-DOF needle driver with fiducial tracking frame and a 3-DOF actuated Cartesian stage. The needle driver provides needle cannula rotation and translation (2-DOF) and stylet translation (1-DOF). The driver mimics the manual physician gesture by two point grasping. To render proprioception associated with prostate interventions, a Fabry Perot interferometer based fiber optic strain sensor is designed to provide high-resolution axial needle insertion force measurement and is robust to large range of temperature variation. The paper explains the robot mechanism, controller design, optical modeling and opto-mechanical design of the force sensor. MRI compatibility of the robot is evaluated under 3T MRI using standard prostate imaging sequences and average signal noise ratio (SNR) loss is limited to 2% during actuator motion. A dynamic needle insertion is performed and bevel tip needle steering capability is demonstrated under continuous real-time MRI guidance, both with no visually identifiable interference during robot motion. Fiber optic sensor calibration validates the theoretical modeling with satisfactory sensing range and resolution for prostate intervention.
Hao Su 0002, Michael Zervas, Gregory A. Cole, Cosme Furlong, Gregory S. Fischer
ICRA3
2009 Design of a robotic system for MRI-guided deep brain stimulation electrode placement
abstract
Deep brain stimulation (DBS) is a technique for influencing brain function though the use of implanted electrodes. Direct magnetic resonance (MR) image guidance during DBS insertion would provide many benefits; most significantly, interventional MRI can be used for planning, monitoring of tissue deformation, real-time visualization of insertion, and confirmation of placement. The accuracy of standard stereotactic insertion is limited by registration errors and brain movement during surgery. With real-time acquisition of high-resolution MR images during insertion, probe placement can be confirmed intra-operatively. Direct MR guidance has not yet taken hold because it is often confounded by a number of issues including: MR-compatibility of existing stereotactic surgery equipment and patient access in the scanner bore. The high resolution images required for neurosurgical planning and guidance require high-field MR (1.5-3 T); thus, any system must be capable of working within the constraints of a closed, long-bore diagnostic magnet. Currently, no technological solution exists to assist MRI guided neurosurgical interventions in an accurate, simple, and economical manner.We present the design of a robotic assistant system that overcomes these difficulties and promises safe and reliable electrode placement in the brain inside closed high-field MRI scanners. The robot performs the insertion under real-time 3 T MR image guidance. This paper described analysis of the workspace requirements, MR compatibility evaluation, and mechanism design.
Gregory A. Cole, Julie Pilitsis, Gregory S. Fischer
ICRA1