Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Toshio Chiba

dblp:90/2190 · DBLP profile ↗
← Back
7ranked-venue papers
0as first author
0since 2021 · last 2011
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 4Systems, architecture and hardware · 4Applied, interdisciplinary, general and emerging computing · 3Graphics, computer vision, multimedia, augmented reality and games · 2Human-computer interaction and ubiquitous computing · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
3 papers
Robot manipulation · 100%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%
Human-computer interaction and pervasive computing
1 paper
Health and well-being technologies · 100%

Topics — the 5 heaviest of 6, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation › medical robotics
surgical robotics
0.222011
Development of 6-DOF wire-driven robotic manipulator for minimally invasive fetal surgery · ICRA 2011
Micro Manipulators for Intrauterine Fetal Surgery in an Open MRI · ICRA 2005
Robotics › Robot manipulation › medical robotics › surgical robotics
minimally invasive surgery
0.112011
Development of 6-DOF wire-driven robotic manipulator for minimally invasive fetal surgery · ICRA 2011
Robotics › Robot manipulation › medical robotics
surgical manipulator
0.112007
Bending Laser Manipulator for Intrauterine Surgery and Viscoelastic Model of Fetal Rat Tissue · ICRA 2007
Robotics › Robot manipulation
micromanipulator
0.112005
Micro Manipulators for Intrauterine Fetal Surgery in an Open MRI · ICRA 2005
Medical and health informatics
surgical robotics
0.012007
Bending Laser Manipulator for Intrauterine Surgery and Viscoelastic Model of Fetal Rat Tissue · ICRA 2007

Methods — techniques the papers use, named apart from their topics

viscoelastic modeling · 0.1creep test · 0.1wire-driven mechanism · 0.1contact force control · 0.1wire-driven bending mechanism · 0.1ball joint mechanism · 0.1
YearPublicationVenuePosition
2011 Development of 6-DOF wire-driven robotic manipulator for minimally invasive fetal surgery
abstract
The clinical target of this study is intratracheal balloon occlusion from minimally invasive fetal surgery for Congenital Diaphragmatic Hernia (CDH). The target for the surgery is prenatal temporary tracheal occlusion which enlarges the fetal lungs, and this procedure is promising for severe cases. A balloon is supposed to be inserted for tracheal occlusion using the manipulator. We propose a novel robotic manipulator for intrauterine fetal surgery for tracheal occlusion. In this study, a prototype of the robotic manipulator using a wire-driven mechanism has been developed. The manipulator is thin in structure and has multiple degrees of freedom to avoid damage to the fragile cells of the fetus. Specifically, we describe our development of the 3-unit robotic manipulator with ball joint-shaped arthroses and shaft diameter of 2.4 mm. The mechanism of the robotic manipulator was designed for providing the bending motion and controlling the contact force at its tip by the tension of the driven wires. Results of the experiment suggested that the contact force was controlled to under 0.04 N to insert the manipulator through the mouth of the fetus into the trachea without causing damage to the fetal tissues or changing the fetal attitude in the uterus.
Bo Zhang 0028, Yo Kobayashi, Yoshinari Maeda, Toshio Chiba, Masakatsu G. Fujie
ICRA4
2011 Development of a robotic manipulator system for Congenital Diaphragmatic Hernia
abstract
The clinical target of this study is intratracheal balloon occlusion from minimally invasive fetal surgery for Congenital Diaphragmatic Hernia (CDH). The target for the surgery is a prenatal temporary tracheal occlusion, which enlarges the fetal lungs, and is a promising procedure for severe cases. A balloon is supposed to be inserted for tracheal occlusion using the manipulator. We propose a novel robotic manipulator for intrauterine fetal surgery for tracheal occlusion. In this study, the 3-unit robotic manipulator with ball joint-shaped arthroses and a shaft diameter of 2.4 mm using a wire-driven mechanism has been developed to approach the fetal trachea without the risk of damage to fetal tissue. The robotic manipulator has a thin structure and 7 degrees of freedom to avoid damage to the fragile fetal cells. However, the positioning control of the robotic manipulator is very difficult. In this paper, the mechanism of the robotic manipulator positioning control was confirmed by measuring the motion of each unit through the experiment. Additionally, a simulation was developed to estimate the mechanism of the robotic manipulator positioning control, and an approach method was considered. The results of the evaluation experiment suggested that the robotic manipulator could approach the fetal trachea through the mouth, and that the contact force was controlled to under 0.05 [N].
Bo Zhang 0028, Yoshinari Maeda, Toshio Chiba, Yo Kobayashi, Masakatsu G. Fujie
SMC3
2009 A Coaxial Laser Endoscope with Arbitrary Spots in Endoscopic View for Fetal Surgery
Noriaki Yamanaka, Hiromasa Yamashita, Ken Masamune, Hongen Liao, Toshio Chiba, Takeyoshi Dohi
MICCAI (1)5
2007 Bending Laser Manipulator for Intrauterine Surgery and Viscoelastic Model of Fetal Rat Tissue
abstract
A bending laser manipulator of 2.4 mm in diameter has been developed for intrauterine fetal surgery. This manipulator deflects a laser fiber in any direction thorough 90 degrees. The results of a positioning test and in vitro/in vivo tests are reported. Meanwhile, creep tests for fetal rat tissue of 16 to 20 days in gestation were performed to evaluate fetal tissue fragility. Unique features of fetal rat tissue compared to other soft organs are discussed and a viscoelastic model of the fetal rat tissue was proposed. The result of the modeling will be used not only for fabricating fetal tissue phantom but also for the force control of robotic application for fetal surgery.
Kanako Harada, Bo Zhang 0028, Shin Enosawa, Toshio Chiba, Masakatsu G. Fujie
ICRA4
2007 Balloon-based manipulator with multiple linkages for intrauterine surgery
abstract
This paper describes a manipulator for controlling position and posture of fetus in uterus and a surgical procedure for supporting the fetus in intrauterine surgery. The manipulator is equipped with multiple linkages and a balloon to support the fetus softly in the uterus. The linkages with two bending mechanisms are designed for inserting the balloon to an optimal position under the fetus. The balloon is fold before the operation and inflated by saline water after arriving at the required position in the uterus. Accuracy evaluation showed that the standard deviations of the bending angle of the wire-driven mechanism and the linkages-driven mechanism were 1.0 degree and 2.5 degree, respectively. Force experiment showed that the balloon-type stabilizer could generate load-bearing power of 500 gf. Furthermore, the manipulator could be well controlled with guidance of ultrasound images. The manipulator could minimize injure to the fetus since the area contacted with the fetus by the balloon could be well controlled.
Noriaki Yamanaka, Kiyoshi Matsumiya, Ken Masamune, Takeyoshi Dohi, Hiromasa Yamashita, Toshio Chiba, Hongen Liao
IROS6
2006 Fetus Support Manipulator with Flexible Balloon-Based Stabilizer for Endoscopic Intrauterine Surgery
Hongen Liao, Hirokazu Suzuki, Kiyoshi Matsumiya, Ken Masamune, Takeyoshi Dohi, Toshio Chiba
MICCAI (1)6
2005 Micro Manipulators for Intrauterine Fetal Surgery in an Open MRI
abstract
We propose a new surgical robotic system for intrauterine fetal surgery in an Open MRI. The target disease of the fetal surgery is spina bifida or myelomeningocele that is incomplete closure in the spinal column and one of the common fetal diseases. In the proposed surgical process, the abdominal wall and uterine wall would not widely be opened but rather surgical instruments inserted through the small holes in both walls to perform minimally invasive surgery. In this paper, a prototype of the micro manipulator of diameter is 2.4mm and bending radius 2.45 mm is presented. The diameter and bending radius of this manipulator is one of the smallest ever developed among surgical robots to the best of the knowledge of the investigating authors. The mechanism of the manipulator includes two ball joints and is driven using four wires able to bend through 90 degrees in any direction. The features of the mechanism include a small diameter, small bending radius, ease of fabrication, high rigidity and applicability for other surgical applications. Although the manipulator is not yet MRI compatible, the feature of the prototype demonstrated the feasibility of robotic intrauterine fetal surgery.
Kanako Harada, Kota Tsubouchi, Toshio Chiba, Masakatsu G. Fujie
ICRA3