Demo Data from SIGIR 2026 / reviewers in the wild / expert
Fabrizio Vecchi
dblp:91/6317
· DBLP profile ↗
11ranked-venue papers
0as first author
0since 2021 · last 2013
0000-0002-8546-0246ORCID · reported
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 9Systems, architecture and hardware · 8Applied, interdisciplinary, general and emerging computing · 3Human-computer interaction and ubiquitous computing · 1
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Human-computer interaction and pervasive computing
3 papers |
Health and well-being technologies · 42% Human-robot interaction · 33% Accessibility and assistive technology · 23% | |
| Artificial intelligence
1 paper |
Motion planning and robot control · 50% Robot manipulation · 50% |
Topics — the 7 heaviest of 9, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Health and well-being technologies › rehabilitation technology
rehabilitation robotics |
0.3 | 2 | 2013 | NEUROExos: A Powered Elbow Exoskeleton for Physical Rehabilitation · IEEE Trans. Robotics 2013 NEUROExos: A variable impedance powered elbow exoskeleton · ICRA 2011 |
Human-robot interaction
physical human-robot interaction |
0.2 | 2 | 2013 | NEUROExos: A Powered Elbow Exoskeleton for Physical Rehabilitation · IEEE Trans. Robotics 2013 NEUROExos: A variable impedance powered elbow exoskeleton · ICRA 2011 |
Robotics › Motion planning and robot control
robot control |
0.2 | 1 | 2013 | NEUROExos: A Powered Elbow Exoskeleton for Physical Rehabilitation · IEEE Trans. Robotics 2013 |
Robotics › Robot manipulation › actuator design › compliant actuator
variable impedance actuation |
0.2 | 1 | 2013 | NEUROExos: A Powered Elbow Exoskeleton for Physical Rehabilitation · IEEE Trans. Robotics 2013 |
Accessibility and assistive technology › assistive technology
assistive exoskeleton |
0.1 | 1 | 2011 | NEUROExos: A variable impedance powered elbow exoskeleton · ICRA 2011 |
Accessibility and assistive technology › prosthetics
prosthetic hand |
0.1 | 1 | 2006 | Hybrid Bionic Systems for the Replacement of Hand Function · Proc. IEEE 2006 |
Wearable and physiological sensing
electromyography |
0.0 | 1 | 2006 | Hybrid Bionic Systems for the Replacement of Hand Function · Proc. IEEE 2006 |
Methods — techniques the papers use, named apart from their topics
torque control · 0.3impedance control · 0.3variable impedance actuation · 0.1antagonistic actuator · 0.1peripheral nerve interface · 0.1electromyographic signal recording · 0.1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2013 | NEUROExos: A Powered Elbow Exoskeleton for Physical RehabilitationabstractThis paper presents the design and experimental testing of the robotic elbow exoskeleton NEUROBOTICS Elbow Exoskeleton (NEUROExos). The design of NEUROExos focused on three solutions that enable its use for poststroke physical rehabilitation. First, double-shelled links allow an ergonomic physical human-robot interface and, consequently, a comfortable interaction. Second, a four-degree-of-freedom passive mechanism, embedded in the link, allows the user's elbow and robot axes to be constantly aligned during movement. The robot axis can passively rotate on the frontal and horizontal planes 30° and 40°, respectively, and translate on the horizontal plane 30 mm. Finally, a variable impedance antagonistic actuation system allows NEUROExos to be controlled with two alternative strategies: independent control of the joint position and stiffness, for robot-in-charge rehabilitation mode, and near-zero impedance torque control, for patient-in-charge rehabilitation mode. In robot-in-charge mode, the passive joint stiffness can be changed in the range of 24-56 N·m/rad. In patient-in-charge mode, NEUROExos output impedance ranges from 1 N·m/rad, for 0.3 Hz motion, to 10 N·m/rad, for 3.2 Hz motion. Nicola Vitiello, Tommaso Lenzi, Stefano Roccella, Stefano Marco Maria De Rossi, Emanuele Cattin, Francesco Giovacchini, Fabrizio Vecchi, Maria Chiara Carrozza |
IEEE Trans. Robotics | 7 |
| 2011 | NEUROExos: A variable impedance powered elbow exoskeletonabstractThis paper introduces NEUROExos, an elbow powered exoskeleton for rehabilitation. The NEUROExos is provided with three novel characteristics which address the major problems arising in rehabilitation robotics. A double shell link structure allows for a comfortable human-robot interaction, while a 4-DOF passive mechanism gives a perfect kinematic compatibility with the user. Moreover, NEUROExos is powered by a variable impedance antagonistic actuator, which provides the exoskeleton with a software-controllable passive compliance. We present the main characteristics of the exoskeleton, with a focus on the actuation and control of the platform. Additionally, results on a healthy subject show the relevance of this design during a prototypical rehabilitation task. Tommaso Lenzi, Nicola Vitiello, Stefano Marco Maria De Rossi, Stefano Roccella, Fabrizio Vecchi, Maria Chiara Carrozza |
ICRA | 5 |
| 2009 | HANDEXOS: Towards an exoskeleton device for the rehabilitation of the handabstractThis paper introduces a novel exoskeleton device (HANDEXOS) for the rehabilitation of the hand for post-stroke patients. The nature of the impaired hand can be summarized in a limited extension, abduction and adduction leaving the fingers in a flexed position, so the exoskeleton goal is to train a safe extension motion from the typical closed position of the impaired hand. The mechanical design of HANDEXOS offers the possibility to overcome the exoskeleton limits often related to the general high level of complexity of the structure, mechanism and actuation. We describe the mechanical design of the index finger module, the dynamic model and some preliminary experimental results. Azzurra Chiri, Francesco Giovacchini, Nicola Vitiello, Emanuele Cattin, Stefano Roccella, Fabrizio Vecchi, Maria Chiara Carrozza |
IROS | 6 |
| 2007 | The NEURARM: towards a platform for joint neuroscience experiments on human motion control theoriesabstractThis paper presents the development of new transmission components and position controller of the NEURARM hydraulic actuation unit as critical components of a novel robotic arm specifically designed to perform joint experiments between neuroscience and robotics. NEURARM replicates the main functions and characteristics of the human arm during the execution of planar movements like reaching and catching, and it was used to investigate human motion control theories, to develop and evaluate models of control, of learning and of sensory-motor interaction. Nicola Vitiello, Emanuele Cattin, Stefano Roccella, Francesco Giovacchini, Fabrizio Vecchi, Maria Chiara Carrozza, Paolo Dario |
IROS | 5 |
| 2006 | Towards a New Generation of Hybrid Bionic Systems for Telepresence: the Lamprey ModelabstractThis paper introduces the main objectives of the neurobotics project aimed at designing and developing innovative hybrid bionic systems (HBSs) by fusing neuroscience and robotics. Eight different HBSs have been jointly designed and are being developed. This paper presents in detail the telepresence platform. The neurobotics artificial lamprey model has been designed to validate a number of neuroscience models and to investigate new telepresence strategies Paolo Dario, Cesare Stefanini, Arianna Menciassi, Cecilia Laschi, Fabrizio Vecchi |
RO-MAN | 5 |
| 2006 | Hybrid Bionic Systems for the Replacement of Hand FunctionabstractIn recent years, thanks to the advancement of robotics and mechatronics, new and more effective devices for the restoration and replacement of sensory-motor function in disabled people have been developed. In all these systems, user acceptability is strictly connected to several issues such as the residual abilities of the subject, the mechatronic characteristics of the robot, and also the interface chosen to link them. It is possible to figure out different "human-interface-device" combinations [also defined as "hybrid bionic systems" (HBSs)] characterized by different properties in terms of level of hybridness, connection, and augmentation. In particular, in HBSs the interface has to be customized according to the characteristics of the robotic artefact to be controlled and to the desires and needs of the final users. In this paper, our attention has been focused on the problem of the replacement of hand function after amputation. Three HBSs characterized by different levels of complexity, dexterity, and sensorization are presented in order to show the possibility of developing acceptable and effective systems by choosing different levels of connection and hybridness (i.e., different interfaces) for different devices and applications. The following case studies are presented: 1) the use of invasive interfaces to the peripheral nervous system to control a dexterous and highly sensorized hand prosthesis; 2) the use of electromyographic signals recorded using surface electrodes to control a compliant adaptive prosthesis; and 3) the use of a foot interface to control a two-degrees-of-freedom prosthesis. The preliminary results achieved so far seem to confirm the idea that the correct choice of the proper interface while developing an HBS can increase effectiveness and usability Silvestro Micera, Maria Chiara Carrozza, Lucia Beccai, Fabrizio Vecchi, Paolo Dario |
Proc. IEEE | 4 |
| 2005 | A Cosmetic Prosthetic Hand with Tendon Driven Under-Actuated Mechanism and Compliant Joints: Ongoing Research and Preliminary ResultsabstractThis paper presents recent results aimed at developing a functional prosthetic hand characterized by an EMG-control and by a simple and low cost fabrication technology. In order to overcome some limitations of current prosthetic hands mainly related to the poor functionality and controllability, the prosthetic hand has been designed following a biomechatronic approach based on biologically-inspired design solutions. The core of the project described in this paper is the fabrication of a compliant under-actuated prosthetic hand: the structure of the hand (both palm and fingers) is moulded as a soft polymeric single part with compliant joints and embedded tendon driven underactuated mechanism for providing adaptive grasp. In order to make user trials, the hand is equipped with simple but functional EMG-based control of the single motor incorporated in the hand, and is integrated with a prosthesis socket. The paper presents the biomechatronics design, the fabrication process, the integration of the prosthetic device and first experimental results. Maria Chiara Carrozza, Giovanni Cappiello, Giovanni Stellin, Franco Zaccone, Fabrizio Vecchi, Silvestro Micera, Paolo Dario |
ICRA | 5 |
| 2005 | On the development of a novel adaptive prosthetic hand with compliant joints: experimental platform and EMG controlabstractIn this paper, some recent results about the experimental trials we are performing on a functional prosthetic hand characterized by an EMG-control and by a simple and low cost fabrication technology are shown. The innovation described in this paper is the fabrication of a compliant under-actuated prosthetic hand. The structure of the hand (both palm and fingers) is moulded as a soft polymeric single part with compliant joints and embedded tendon driven under-actuated mechanism for providing adaptive grasp. The prosthetic hand has been designed following a biomechatronic approach based on biologically-inspired design solutions. We describe the second release of this prosthesis. The evaluating tests are related to the maximum force exerted during grasping and to the fatigue problems occurring with cables and joint. Maria Chiara Carrozza, Giovanni Cappiello, Giovanni Stellin, Franco Zaccone, Fabrizio Vecchi, Silvestro Micera, Paolo Dario |
IROS | 5 |
| 2005 | A novel wearable foot interface for controlling robotic handsabstractThis paper presents an experimental investigation on a novel interface for high level control of robotic hands, based on selected foot movements. A prototype has been developed that integrates 4 sensitive areas, battery, and electronics for data acquisition and wireless transmission into a wearable insole. The prototype foot interface has been experimentally validated in the control of a robotic hand prosthesis. Comparative experimental trials were conducted with 10 able-bodied subjects, with both the foot interface and an EMG-based control, which represents the most advanced interface currently available in clinical implants for amputees. The results confirmed the effectiveness of the foot interface in the control of the hand prosthesis and showed a significant decrease in required adaptation and learning from the user's side. Maria Chiara Carrozza, Alessandro Persichetti, Cecilia Laschi, Fabrizio Vecchi, Pierpaolo Vacalebri, Vincenzo Tamburrelli, Roberto Lazzarini, Paolo Dario |
IROS | 4 |
| 2003 | Experimental analysis of an innovative prosthetic hand with proprioceptive sensorsabstractThis paper presents an underactuated artificial hand intended for functional replacement of the natural hand in upper limb amputees. The natural hand has three basic functionalities: grasping, manipulation and exploration. To accomplish the goal of restoring these capabilities by implanting an artificial hand, two fundamental steps are necessary: to develop an artificial hand equipped with artificial proprioceptive and exteroceptive sensors and to fabricate an appropriate interface able to exchange sensory-motor signals with the amputee's body and the central nervous system. In order to address these objectives, we have studied an underactuated hand according to a biomimetic approach, and we have exploited robotic and microengineering technologies to design and fabricate its building blocks. The architecture of the hand comprises the following modules: an actuator system embedded in the underactuated mechanical structure (artificial musculoskeletal system), a proprioceptive sensory system (position and force sensors), an exteroceptive sensory system (3D force sensors distributed on the cosmetic glove), an embedded control unit, and a human/machine interface. The first prototype of the artificial hand has been designed and fabricated. The hand is underactuated, and is equipped with opposable thumb and a proprioceptive sensory system. This paper presents the fabrication and experimental characterization of the hand, focusing on the mechanical structure, the actuator system and the proprioceptive sensory system. Maria Chiara Carrozza, Fabrizio Vecchi, Fabrizio Sebastiani 0002, Giovanni Cappiello, Stefano Roccella, Massimiliano Zecca, Roberto Lazzarini, Paolo Dario |
ICRA | 2 |
| 2003 | The Cyberhand: on the design of a cybernetic prosthetic hand intended to be interfaced to the peripheral nervous systemabstractThe objective of the project described in this paper is the development of a cybernetic prosthesis, replicating as much as possible the sensory-motor capabilities of the natural hand. The human hand is not only an effective tool but also an ideal instrument to acquire information from the external environment. The development of a truly human-like artificial hand is probably the most widely known paradigm of "bionics". The Cyberhand Project aims to obtain a cybernetic prosthetic hand interfaced to the peripheral nervous system. In particular this paper is focused on the hand mechanisms design and it presents preliminary results in developing the three fingered anthropomorphic hand prototype and its sensory system. Maria Chiara Carrozza, Paolo Dario, Fabrizio Vecchi, Stefano Roccella, Massimiliano Zecca, Fabrizio Sebastiani 0002 |
IROS | 3 |