Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Tiancheng Li 0003

dblp:92/250-3 · DBLP profile ↗
← Back
3ranked-venue papers
2as first author
3since 2021 · last 2025
0000-0003-2215-1232ORCID · conflict

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 2 · 1 first-author · 2 since 2021Systems, architecture and hardware · 2 · 1 first-author · 2 since 2021Graphics, computer vision, multimedia, augmented reality and games · 1 · 1 first-author · 1 since 2021Applied, interdisciplinary, general and emerging computing · 1 · 1 first-author · 1 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%
Artificial intelligence
1 paper
3D vision · 100%

Topics — the 2 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics › computer-assisted surgery
computer-assisted orthopedic surgery
0.912025
Partial-to-Full Registration based on Gradient-SDF for Computer-Assisted Orthopedic Surgery · ICRA 2025
Computer vision › 3D vision
point cloud registration
0.312025
Partial-to-Full Registration based on Gradient-SDF for Computer-Assisted Orthopedic Surgery · ICRA 2025

Methods — techniques the papers use, named apart from their topics

signed distance field registration · 1.7gradient-SDF · 1.7
YearPublicationVenuePosition
2025 Partial-to-Full Registration based on Gradient-SDF for Computer-Assisted Orthopedic Surgery
abstract
In computer-assisted orthopedic surgery (CAOS), accurate pre-operative to intra-operative bone registration is an essential and critical requirement for providing navigational guidance. This registration process is challenging since the intra-operative 3D points are sparse, only partially overlapped with the pre-operative model, and disturbed by noise and outliers. The commonly used method in current state-of-the-art orthopedic robotic system is bony landmarks based registration, but it is very time-consuming for the surgeons. To address these issues, we propose a novel partial-to-full registration framework based on gradient-SDF for CAOS. The simulation experiments using bone models from publicly available datasets and the phantom experiments performed under both optical tracking and electromagnetic tracking systems demonstrate that the proposed method can provide more accurate results than standard benchmarks and be robust to 90% outliers. Importantly, our method achieves convergence in less than 1 second in real scenarios and mean target registration error values as low as 2.198 mm for the entire bone model. Finally, it only requires random acquisition of points for registration by moving a surgical probe over the bone surface without the need for correspondences, thus showing significant potential clinical value. The code of the framework is available*.
Tiancheng Li 0003, Peter Walker, Danial Hammoud, Liang Zhao 0003, Shoudong Huang
ICRA1
2025 Physical Human-Robot Collaboration-Assisted Acetabular Preparation for Total Hip Replacement Surgery
abstract
When performing total hip replacement (THR) surgery, high-quality preparation of acetabulum is critical as it contributes to the patient’s recovery speed and the consistency of bone ingrowth. Conventionally, surgeons prepare the acetabulum manually by reaming it with a handheld electric drill and a reamer. It not only increases the surgeon’s workload but more importantly, it is difficult to control the reaming depth and direction accurately. Utilizing an admittance-controlled (AC) collaborative robot (cobot) to enable physical human-robot collaboration (pHRC) possesses a promising solution. For primitive AC, a compromise must be made between compliance and task accuracy. In this paper, we present a novel variable admittance control (VAC) design that considers the reactive force of bone while ensuring the passivity and stability of the system during pHRC-assisted acetabular preparation. The qualitative results show that VAC was more desirable by users than the conventional manual reaming method. Compared to other pHRC controls, quantitative results on user energy consumption, reaming error, and smoothness showed the proposed VAC can achieve a balance between physical workload and acetabular quality. Compared to manual reaming, VAC reduced the reaming error by 67.47% and improved the final acetabulum surface smoothness by 18.30%.
Tiancheng Li 0003, Marc Carmichael, Shoudong Huang
IROS2
2023 A Closed-Form Solution to Electromagnetic Sensor Based Intraoperative Limb Length Measurement in Total Hip Arthroplasty
Tiancheng Li 0003, Yang Song 0028, Peter Walker, Kai Pan, Victor A. van de Graaf, Liang Zhao 0003, Shoudong Huang
MICCAI (9)1