Demo Data from SIGIR 2026 / reviewers in the wild / expert
Holger Weiss
dblp:93/2482
· DBLP profile ↗
1ranked-venue papers
0as first author
0since 2021 · last 2006
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 1Systems, architecture and hardware · 1
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
1 paper |
Motion planning and robot control · 87% 3D vision · 13% | |
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% |
Topics — the 4 heaviest of 4, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Motion planning and robot control › robot control
impedance control |
0.1 | 1 | 2006 | A Hands-on-robot for Accurate Placement of Pedicle Screws · ICRA 2006 |
Robotics › Motion planning and robot control
robot control |
0.1 | 1 | 2006 | A Hands-on-robot for Accurate Placement of Pedicle Screws · ICRA 2006 |
Medical and health informatics
surgical robotics |
0.1 | 1 | 2006 | A Hands-on-robot for Accurate Placement of Pedicle Screws · ICRA 2006 |
Computer vision › 3D vision
optical navigation |
0.0 | 1 | 2006 | A Hands-on-robot for Accurate Placement of Pedicle Screws · ICRA 2006 |
Methods — techniques the papers use, named apart from their topics
torque sensing · 0.1preoperative planning · 0.1optical tracking · 0.1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2006 | A Hands-on-robot for Accurate Placement of Pedicle ScrewsabstractThis paper presents a novel system for accurate placement of pedicle screws. The system consists of a new light-weight (<10 kg), kinematically redundant, and fully torque controlled robot. Additionally, the pose of the robot tool-center point is tracked by an optical navigation system, serving as an external reference source. Therefore, it is possible to measure and to compensate deviations between the intraoperative and the preoperatively planned pose. The robotic arm itself is impedance controlled. This allows for a new intuitive man-machine-interface as the joint units are equipped with torque sensors: the robot can be moved just by pulling/pushing its structure. The surgeon has full control of the robot at every step of the intervention. The hand-eye-coordination problems known from manual pedicle screw placement can be omitted Tobias Ortmaier, Holger Weiss, Ulrich Hagn, Markus Grebenstein, Matthias Nickel, Alin Albu-Schäffer, Christian Ott 0001, Stefan Jörg, Rainer Konietschke, Luc Le Tien, Gerd Hirzinger |
ICRA | 2 |