Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Rajarshi Roy 0005

dblp:94/4026-5 · DBLP profile ↗
← Back
5ranked-venue papers
2as first author
0since 2021 · last 2016
0000-0003-2795-056XORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 4 · 1 first-authorSystems, architecture and hardware · 4 · 1 first-authorApplied, interdisciplinary, general and emerging computing · 1 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
3 papers
Robot manipulation · 72% Robot navigation and mapping · 28%
Interdisciplinary, comprehensive, and emerging computing
3 papers
Medical and health informatics · 100%
Theoretical computer science
1 paper
Mathematical optimization · 100%

Topics — the 8 heaviest of 8, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation
medical robotics
0.212016
Using Bayesian optimization to guide probing of a flexible environment for simultaneous registration and stiffness mapping · ICRA 2016
Robotics › Robot manipulation › contact modeling
stiffness mapping
0.212016
Using Bayesian optimization to guide probing of a flexible environment for simultaneous registration and stiffness mapping · ICRA 2016
Robotics › Robot navigation and mapping
surgical navigation
0.212016
Using Bayesian optimization to guide probing of a flexible environment for simultaneous registration and stiffness mapping · ICRA 2016
Medical and health informatics
computer-assisted surgery
0.212016
Complementary model update: A method for simultaneous registration and stiffness mapping in flexible environments · ICRA 2016
Medical and health informatics › surgical robotics
robot-assisted surgery
0.212016
Concurrent nonparametric estimation of organ geometry and tissue stiffness using continuous adaptive palpation · ICRA 2016
Mathematical optimization
bayesian optimization
0.212016
Using Bayesian optimization to guide probing of a flexible environment for simultaneous registration and stiffness mapping · ICRA 2016
Robotics › Robot manipulation › deformable object manipulation
deformation compensation
0.112016
Complementary model update: A method for simultaneous registration and stiffness mapping in flexible environments · ICRA 2016
Robotics › Robot manipulation
tactile sensing
0.112016
Concurrent nonparametric estimation of organ geometry and tissue stiffness using continuous adaptive palpation · ICRA 2016

Methods — techniques the papers use, named apart from their topics

gaussian process · 1.2bayesian optimization · 0.8objective function minimization · 0.5continuous adaptive palpation · 0.5complementary model update · 0.5
YearPublicationVenuePosition
2016 Using Bayesian optimization to guide probing of a flexible environment for simultaneous registration and stiffness mapping
abstract
One of the goals of computer-aided surgery is to register intraoperative data to preoperative model of the anatomy, and hence add complementary information that can facilitate the task of surgical navigation. In this context, mechanical palpation can reveal critical anatomical features such as arteries and cancerous lumps which are stiffer than the surrounding tissue. This work uses position and force measurements obtained during mechanical palpation for registration and stiffness mapping. Prior approaches, including our own, exhaustively palpated the entire organ to achieve this goal. To overcome the costly palpation of the entire organ, a Bayesian optimization framework is introduced to guide the end effector to palpate stiff regions while simultaneously updating the registration of the end effector to an a priori geometric model of the organ, hence enabling the fusion of intraoperative data into the a priori model obtained through imaging. This new framework uses Gaussian processes to model the stiffness distribution and Bayesian optimization to direct where to sample next for maximum information gain. The proposed method was evaluated with experimental data obtained using a Cartesian robot interacting with a silicone organ model and an ex vivo porcine liver.
Elif Ayvali, Rangaprasad Arun Srivatsan, Long Wang 0007, Rajarshi Roy 0005, Nabil Simaan, Howie Choset
ICRA4
2016 Concurrent nonparametric estimation of organ geometry and tissue stiffness using continuous adaptive palpation
abstract
Surgeons often manually palpate tissue or organs in order to find tumors or other anatomical structures. Information about organ geometry and tissue stiffness gained from palpation can also be extremely useful in robotic surgery for diagnosis, surgical guidance, and registration to other preoperative information. However, it is not always easy to obtain, even if the robot is equipped with force sensors. This paper reports our approach for concurrent estimation of stiffness and surface geometry, using a continuous motion similar to a sweeping palpation motion used by surgeons. Our method relies on force data captured by a tactile sensor rigidly attached to an end-effector probe. We use Gaussian processes to simultaneously estimate geometry and stiffness. The method is not tied to any specific robotic platform and is consistent with a variety of palpation strategies. For simplicity, we discuss the results based on two different palpation primitives. This is our first step towards developing an adaptive high fidelity model reconstruction and path optimization technique.
Preetham Chalasani, Long Wang 0007, Rajarshi Roy 0005, Nabil Simaan, Russell H. Taylor, Marin Kobilarov
ICRA3
2016 Investigation of effects of dynamics on intrinsic wrench sensing in continuum robots
abstract
Multi-backbone continuum robots have been demonstrated to possess wrench sensing capabilities by measuring the actuation load on each backbone and then using elaborate statics models. The ability to sense forces of interaction allows these robots to also control their interaction with the environment. In past studies, the force sensing models were subject to quasi-static assumptions. The goal of this paper is threefold: to update the wrench sensing model taking into account dynamic forces, to investigate the effect of these dynamic forces on the wrench sensing abilities of these robots and to present design atlases that help designers with the determination of critical dimensions ensuring bounded effect of dynamics on wrench sensing. The paper presents a simplified dynamics model using a Lagrangian formulation. This dynamics model is then used to update the wrench estimation model for a single-segment continuum robot. Finally, a set of normalized parameters is used to produce design atlases that help designers predict the effect of dynamics on the wrench estimation model. These results will allow improved performance in force sensing and control for multi-backbone continuum robots. Employing the methods presented in the paper, continuum robots, that have previously demonstrated excellent distal dexterity, will be able to control their force interaction with the anatomy better in future - thereby improving safety and the finesse of surgery.
Rajarshi Roy 0005, Long Wang 0007, Nabil Simaan
ICRA1
2016 Complementary model update: A method for simultaneous registration and stiffness mapping in flexible environments
abstract
Registering a surgical tool to an a priori model of the environment is an important first step in computer-aided surgery. In this paper we present an approach for simultaneous registration and stiffness mapping using blind exploration of flexible environments. During contact-based exploration of flexible environments, the physical interaction with the environment can induce local deformation, leading to erroneous registration if not accounted for. To overcome this issue, a new registration method called complementary model update (CMU), is introduced. By incorporating measurements of the contact force, and contact location, we minimize a unique objective function to cancel out the effect of local deformation. We are thus able to acquire the necessary registration parameters using both geometry and stiffness information. The proposed CMU method is evaluated in simulation and using experimental data obtained by probing silicone models and an ex vivo organ.
Rangaprasad Arun Srivatsan, Elif Ayvali, Long Wang 0007, Rajarshi Roy 0005, Nabil Simaan, Howie Choset
ICRA4
2013 A Semi-Automated Positioning System for Contact-Mode Atomic Force Microscopy (AFM)
abstract
Human breast tissue is by nature heterogeneous, and in the samples we studied, epithelial tissue is formed by groups of functional breast epithelial cells that are surrounded by stromal tissue in a complex intertwined way. Therefore sampling a specific cell type on an unstained specimen is very difficult. To aid us, we use digital stained images of the same tissue annotated by a certified pathologist to identify the region of interest (ROI) at a coarse magnification and an image-guided positioning system to place the unstained tissue near the AFM probe tip. Using our setup, we could considerably reduce AFM operating time and we believe that our setup is a viable supplement to commercial AFM stages with limited X-Y range.
Rajarshi Roy 0005, Wenjin Chen, Lei Cong, Lauri A. Goodell, David J. Foran, Jaydev P. Desai
IEEE Trans Autom. Sci. Eng.1