Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Haim Azhari

dblp:95/6935 · DBLP profile ↗
← Back
5ranked-venue papers
1as first author
0since 2021 · last 2006
0000-0001-5862-2206ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 4 · 1 first-authorGraphics, computer vision, multimedia, augmented reality and games · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
1 paper
Bioinformatics and computational biology · 44% Medical and health informatics · 44% Computational science and engineering · 13%

Topics — the 3 heaviest of 3, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics
cardiac modeling
0.011988
Three-dimensional computer simulation of the cardiac system · Proc. IEEE 1988
Bioinformatics and computational biology › systems biology
physiological modeling
0.011988
Three-dimensional computer simulation of the cardiac system · Proc. IEEE 1988
Computational science and engineering
finite element analysis
0.011988
Three-dimensional computer simulation of the cardiac system · Proc. IEEE 1988

Methods — techniques the papers use, named apart from their topics

finite element method · 0.0
YearPublicationVenuePosition
2006 Super-resolution in PET imaging
abstract
This paper demonstrates a super-resolution method for improving the resolution in clinical positron emission tomography (PET) scanners. Super-resolution images were obtained by combining four data sets with spatial shifts between consecutive acquisitions and applying an iterative algorithm. Super-resolution attenuation corrected PET scans of a phantom were obtained using the two-dimensional and three-dimensional (3-D) acquisition modes of a clinical PET/computed tomography (CT) scanner (Discovery LS, GEMS). In a patient study, following a standard 18F-FDG PET/CT scan, a super-resolution scan around one small lesion was performed using axial shifts without increasing the patient radiation exposure. In the phantom study, smaller features (3 mm) could be resolved axially with the super-resolution method than without (6 mm). The super-resolution images had better resolution than the original images and provided higher contrast ratios in coronal images and in 3-D acquisition transaxial images. The coronal super-resolution images had superior resolution and contrast ratios compared to images reconstructed by merely interleaving the data to the proper axial location. In the patient study, super-resolution reconstructions displayed a more localized 18F-FDG uptake. A new approach for improving the resolution of PET images using a super-resolution method has been developed and experimentally confirmed, employing a clinical scanner. The improvement in axial resolution requires no changes in hardware.
John A. Kennedy, Ora Israel, Alex Frenkel, Rachel Bar-Shalom, Haim Azhari
IEEE Trans. Medical Imaging5
2002 Speakers' direction finding using estimated time delays in the frequency domain
Baruch Berdugo, Judith Rosenhouse, Haim Azhari
Signal Process.3
2002 Reconstruction in Diffraction Ultrasound Tomography Using Non-Uniform FFT
abstract
We show an iterative reconstruction framework for diffraction ultrasound tomography. The use of broad-band illumination allows significant reduction of the number of projections compared to straight ray tomography. The proposed algorithm makes use of forward nonuniform fast Fourier transform (NUFFT) for iterative Fourier inversion. Incorporation of total variation regularization allows the reduction of noise and Gibbs phenomena while preserving the edges. The complexity of the NUFFT-based reconstruction is comparable to the frequency-domain interpolation (gridding) algorithm, whereas the reconstruction accuracy (in sense of the L2 and the L(infinity) norm) is better.
Michael M. Bronstein, Alexander M. Bronstein, Michael Zibulevsky, Haim Azhari
IEEE Trans. Medical Imaging4
1999 On the Human Left Ventricular Shape
Haim Azhari, Rafael Beyar, Samuel Sideman
Comput. Biomed. Res.1
1988 Three-dimensional computer simulation of the cardiac system
abstract
An integrated approach to modeling the cardiac system is described and related to physiological measurements and other model approaches. The model is composed of a number of parts that will ultimately be used as a tool to study the various functions of the cardiac system. The 3-D geometry of the LV is reconstructed by using a helical coordinate system which provides a quantitative tool for shape description and analysis. Analysis of the regular geometry may be achieved using either the analytical helical system or a finite element technique. A simplified geometry is used to study the physiological interrelationship between the global ventricular function and the transmural temporal distribution of parameters which relate to mechanics, perfusion, energetics, and temperature in the myocardium. Transmural electrical activation maps are calculated based on analytical as well as a finite-element approach, eventually to be used in combination with the mechanical model to study LV contraction.>
Samuel Sideman, Rafael Beyar, Haim Azhari, Efrath Barta, Dan R. Adam, Uri Dinnar
Proc. IEEE3