Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Tianyao Chen

dblp:164/8228 · DBLP profile ↗
← Back
5ranked-venue papers
1as first author
0since 2021 · last 2019
0000-0002-5832-6930ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 3Systems, architecture and hardware · 2Applied, interdisciplinary, general and emerging computing · 2 · 1 first-authorGraphics, computer vision, multimedia, augmented reality and games · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
4 papers
Robot manipulation · 66% Efficient and distributed learning · 26% Image recognition and object detection · 4%
Human-computer interaction and pervasive computing
2 papers
Health and well-being technologies · 84% Haptics and multimodal interaction · 16%

Topics — the 10 heaviest of 12, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation › wearable robotics
exoskeleton
0.412019
An Elbow Exoskeleton for Upper Limb Rehabilitation With Series Elastic Actuator and Cable-Driven Differential · IEEE Trans. Robotics 2019
Robotics › Robot manipulation › medical robotics
rehabilitation robotics
0.412019
An Elbow Exoskeleton for Upper Limb Rehabilitation With Series Elastic Actuator and Cable-Driven Differential · IEEE Trans. Robotics 2019
Robotics › Robot manipulation › actuator design › compliant actuator
series elastic actuator
0.412019
An Elbow Exoskeleton for Upper Limb Rehabilitation With Series Elastic Actuator and Cable-Driven Differential · IEEE Trans. Robotics 2019
Machine learning › Efficient and distributed learning › automated machine learning › neural architecture search
network morphism
0.312018
Efficient Architecture Search by Network Transformation · AAAI 2018
Machine learning › Efficient and distributed learning › automated machine learning
neural architecture search
0.312018
Efficient Architecture Search by Network Transformation · AAAI 2018
Robotics › Robot manipulation › wearable robotics › prosthetic device
ankle-foot prosthesis
0.212015
An ankle-foot prosthesis emulator with control of plantarflexion and inversion-eversion torque · ICRA 2015
Robotics › Robot manipulation › wearable robotics
prosthetic device
0.212015
An ankle-foot prosthesis emulator with control of plantarflexion and inversion-eversion torque · ICRA 2015
Robotics › Legged, aerial and field robots › legged robots
bipedal walking
0.112018
An Ankle-Foot Prosthesis Emulator With Control of Plantarflexion and Inversion-Eversion Torque · IEEE Trans. Robotics 2018
Computer vision › Image recognition and object detection
image classification
0.112018
Efficient Architecture Search by Network Transformation · AAAI 2018
Haptics and multimodal interaction
haptic rendering
0.112015
An ankle-foot prosthesis emulator with control of plantarflexion and inversion-eversion torque · ICRA 2015

Methods — techniques the papers use, named apart from their topics

closed-loop torque control · 1.1strain gauge sensing · 0.7series elasticity · 0.7strain gages · 0.4torque control · 0.4impedance control · 0.4reinforcement learning · 0.3function-preserving transformations · 0.3
YearPublicationVenuePosition
2019 An Elbow Exoskeleton for Upper Limb Rehabilitation With Series Elastic Actuator and Cable-Driven Differential
abstract
Movement impairments resulting from neurologic injuries, such as stroke, can be treated with robotic exoskeletons that assist with movement retraining. Exoskeleton designs benefit from low impedance and accurate torque control. We designed a 2 degree-of-freedom tethered exoskeleton that can provide independent torque control on elbow flexion/extension and forearm supination/pronation. Two identical series elastic actuators (SEAs) are used to actuate the exoskeleton. The two SEAs are coupled through a novel cable-driven differential. The exoskeleton is compact and lightweight, with a mass of 0.9 kg. Applied RMS torque errors were less than 0.19 Nm. Benchtop tests demonstrated a torque rise time of approximately 0.1 s, a torque control bandwidth of 3.7 Hz and an impedance of less than 0.03 Nm/deg at 1 Hz. The controller can simulate a stable maximum wall stiffness of 0.45 Nm/deg. The overall performance is adequate for robotic therapy applications and the novelty of the design is discussed.
Tianyao Chen, Rafael Casas, Peter S. Lum
IEEE Trans. Robotics1
2018 Efficient Architecture Search by Network Transformation
abstract
Techniques for automatically designing deep neural network architectures such as reinforcement learning based approaches have recently shown promising results. However, their success is based on vast computational resources (e.g. hundreds of GPUs), making them difficult to be widely used. A noticeable limitation is that they still design and train each network from scratch during the exploration of the architecture space, which is highly inefficient. In this paper, we propose a new framework toward efficient architecture search by exploring the architecture space based on the current network and reusing its weights. We employ a reinforcement learning agent as the meta-controller, whose action is to grow the network depth or layer width with function-preserving transformations. As such, the previously validated networks can be reused for further exploration, thus saves a large amount of computational cost. We apply our method to explore the architecture space of the plain convolutional neural networks (no skip-connections, branching etc.) on image benchmark datasets (CIFAR-10, SVHN) with restricted computational resources (5 GPUs). Our method can design highly competitive networks that outperform existing networks using the same design scheme. On CIFAR-10, our model without skip-connections achieves 4.23% test error rate, exceeding a vast majority of modern architectures and approaching DenseNet. Furthermore, by applying our method to explore the DenseNet architecture space, we are able to achieve more accurate networks with fewer parameters.
Han Cai, Tianyao Chen, Weinan Zhang 0001, Yong Yu 0001, Jun Wang 0012
AAAI2
2018 An Ankle-Foot Prosthesis Emulator With Control of Plantarflexion and Inversion-Eversion Torque
abstract
Ankle inversion-eversion compliance is an important feature of conventional prosthetic feet, and control of inversion, or roll, in active prostheses could improve balance for people with amputation. We designed a tethered ankle-foot prosthesis with two independently actuated toes that are coordinated to provide plantarflexion and inversion-eversion torques. A Bowden cable tether provides series elasticity. The prosthesis is simple and lightweight, with a mass of 0.72kg. Strain gauges on the toes measure torque with less than 1% root mean squared (RMS) error. Benchtop tests demonstrated a step response rise time of less than 33 ms, peak torques of 250 N·m in plantarflexion and ±30 N·m in inversion-eversion, and peak power above 3 kW. The phase-limited closed-loop torque bandwidth is 20 Hz with a chirp from 10 to 90 N·m in plantarflexion, and 24 Hz with a chirp from -20 to 20 N·m in inversion. The system has low sensitivity to toe position disturbances at frequencies of up to 18 Hz. Walking trials with an amputee subject demonstrated RMS torque tracking errors of less than 5.1 N·m in plantarflexion and less than 1.5 N·m in inversion-eversion. These properties make the platform suitable for testing inversion-related prosthesis features and controllers in experiments with humans.
Myunghee Kim, Tianjian Chen, Tianyao Chen, Steven H. Collins
IEEE Trans. Robotics3
2016 A hybrid hydrostatic transmission and human-safe haptic telepresence robot
abstract
We present a new type of hydrostatic transmission that uses a hybrid air-water configuration, analogous to N+1 cable-tendon transmissions, using N hydraulic lines and 1 pneumatic line for a system with N degrees of freedom (DOFs). The common air-filled line preloads all DOFs in the system, allowing bidirectional operation of every joint. This configuration achieves the high stiffness of a water-filled transmission with half the number of bulky hydraulic lines. We implemented this transmission using pairs of rolling-diaphragm cylinders to form rotary hydraulic actuators, with a new design achieving a 600-percent increase in specific work density per cycle. These actuators were used to build a humanoid robot with two 4-DOF arms, connected via the hydrostatic transmission to an identical master. Stereo cameras mounted on a 2-DOF servo-controlled neck stream live video to the operator's head-mounted display, which in turn sends the real-time attitude of the operator's head to the neck servos in the robot. The operator is visually immersed in the robot's physical workspace, and through the bilateral coupling of the low-impedance hydrostatic transmission, directly feels interaction forces between the robot and external environment. We qualitatively assessed the performance of this system for remote object manipulation and use as a platform to safely study physical human-robot interaction.
John Peter Whitney, Tianyao Chen, John Mars, Jessica K. Hodgins
ICRA2
2015 An ankle-foot prosthesis emulator with control of plantarflexion and inversion-eversion torque
abstract
Ankle inversion-eversion compliance is an important feature of conventional prosthetic feet, and control of inversion, or roll, in robotic prostheses could improve balance for people with amputation. We designed a tethered ankle-foot prosthesis with two independently-actuated toes that are coordinated to provide plantarflexion and inversion-eversion torques. This configuration allows a simple lightweight structure with a total mass of 0.72 kg. Strain gages on the toes measure torque with less than 2.7% RMS error, while compliance in the Bowden cable tether provides series elasticity. Benchtop tests demonstrated a 90% rise time of less than 33 ms and peak torques of 180 N·m in plantarflexion and ±30 N·m in inversion-eversion. The phase-limited closedloop torque bandwidth is 20 Hz with a 90 N·m amplitude chirp in plantarflexion, and 24 Hz with a 20 N·m amplitude chirp in inversion-eversion. The system has low sensitivity to toe position disturbances at frequencies of up to 18 Hz. Walking trials with five values of constant inversion-eversion torque demonstrated RMS torque tracking errors of less than 3.7% in plantarflexion and less than 5.9% in inversion-eversion. These properties make the platform suitable for haptic rendering of virtual devices in experiments with humans, which may reveal strategies for improving balance or allow controlled comparisons of conventional prosthesis features. A similar morphology may be effective for autonomous devices.
Steven H. Collins, Myunghee Kim, Tianjian Chen, Tianyao Chen
ICRA4