Demo Data from VLDB 2026 / reviewers in the wild / expert
Reymond Clavel
dblp:17/3678
· DBLP profile ↗
12ranked-venue papers
0as first author
0since 2021 · last 2011
0009-0008-9532-0870ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 12Systems, architecture and hardware · 12
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
7 papers |
Robot manipulation · 64% Motion planning and robot control · 36% | |
| Human-computer interaction and pervasive computing
2 papers |
Haptics and multimodal interaction · 76% Immersive interaction · 16% Health and well-being technologies · 8% | |
| Computer architecture, parallel and distributed computing, and storage systems
1 paper |
Embedded and real-time systems · 77% Integrated circuit design · 23% |
Topics — the 15 heaviest of 18, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Motion planning and robot control
robot calibration |
0.2 | 2 | 2011 | Ultra-high-precision industrial robots calibration · ICRA 2011 Thermal calibration of a 3 DOF ultra high-precision robot operating in industrial environment · ICRA 2010 |
Robotics › Robot manipulation › micro/nano manipulation
nanorobotic manipulation |
0.1 | 1 | 2009 | NanoLab: A nanorobotic system for automated pick-and-place handling and characterization of CNTs · ICRA 2009 |
Robotics › Robot manipulation › grasping
pick-and-place |
0.1 | 1 | 2009 | NanoLab: A nanorobotic system for automated pick-and-place handling and characterization of CNTs · ICRA 2009 |
Robotics › Robot manipulation › micromanipulation
microgripper |
0.1 | 2 | 2009 | Shape Memory Alloy Microgripper for Robotic Microassembly of Tissue Engineering Scaffolds · ICRA 2004 NanoLab: A nanorobotic system for automated pick-and-place handling and characterization of CNTs · ICRA 2009 |
Robotics › Robot manipulation
parallel manipulator |
0.0 | 1 | 2004 | Study of the Sources of Inaccuracy of a 3 DOF Flexure Hinge-based Parallel Manipulator · ICRA 2004 |
Haptics and multimodal interaction
haptic interface |
0.0 | 2 | 1998 | Haptic Interface for Virtual Reality Based Minimally Invasive Surgery Simulation · ICRA 1998 The PantoScope: a spherical remote-center-of-motion parallel manipulator for force reflection · ICRA 1997 |
Robotics › Motion planning and robot control › robot control › motion control
precision control |
0.0 | 1 | 2011 | Ultra-high-precision industrial robots calibration · ICRA 2011 |
Robotics › Robot manipulation › micromanipulation
microassembly |
0.0 | 1 | 2002 | Robotic Micro-Assembly of Scaffold/Cell Constructs with a Shape Memory Alloy Gripper · ICRA 2002 |
Robotics › Motion planning and robot control › robot control
parallel robot control |
0.0 | 1 | 2010 | Thermal calibration of a 3 DOF ultra high-precision robot operating in industrial environment · ICRA 2010 |
Embedded and real-time systems › cyber-physical systems › robot systems
microrobotics |
0.0 | 1 | 2000 | Issues in Precision Motion Control and Microhandling · ICRA 2000 |
Haptics and multimodal interaction › haptic feedback
force feedback |
0.0 | 1 | 1997 | The PantoScope: a spherical remote-center-of-motion parallel manipulator for force reflection · ICRA 1997 |
Computational fabrication › assembly
micro assembly |
0.0 | 1 | 2004 | Shape Memory Alloy Microgripper for Robotic Microassembly of Tissue Engineering Scaffolds · ICRA 2004 |
Immersive interaction
virtual reality |
0.0 | 2 | 1998 | Haptic Interface for Virtual Reality Based Minimally Invasive Surgery Simulation · ICRA 1998 The PantoScope: a spherical remote-center-of-motion parallel manipulator for force reflection · ICRA 1997 |
Integrated circuit design
microelectromechanical systems |
0.0 | 1 | 2000 | Issues in Precision Motion Control and Microhandling · ICRA 2000 |
Health and well-being technologies › medical simulation
surgical simulation |
0.0 | 1 | 1998 | Haptic Interface for Virtual Reality Based Minimally Invasive Surgery Simulation · ICRA 1998 |
Methods — techniques the papers use, named apart from their topics
finite element simulation · 0.2nano-indentation · 0.1thermal behavior modeling · 0.1scanning electron microscopy · 0.1mobile microrobots · 0.1laser annealing · 0.1error analysis · 0.1system control · 0.1simulation · 0.0finite element method · 0.0ultraprecision design · 0.0implicit force control · 0.0gravity compensation · 0.0parallel manipulator · 0.0geometric model · 0.0
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2011 | Ultra-high-precision industrial robots calibrationabstractThis paper furnishes the theoretical basis to perform the calibration of one or more ultra-high-precision industrial robots operating in the same workspace. We propose a new calibration procedure that keeps in account the factors that lower the robot accuracy at nanometer scale. To validate this approach, we present the practical case of the calibration of a two industrial robots system. Finally, we propose nano-indentation as an alternative method to evaluate the final accuracy reached by the system after calibration. Emanuele Lubrano, Mohamed Bouri, Reymond Clavel |
ICRA | 3 |
| 2010 | Thermal calibration of a 3 DOF ultra high-precision robot operating in industrial environmentabstractWhile dealing with sub-micrometer precision robots, thermal expansion is the most significant source of inaccuracy. Thermal variations in the environment, in the robot parts and in the frame change the robot geometry, lowering the robot precision. In this article we propose a strategy to model and compensate such effects. The thermal behavior of a 3 DOF (Degree(s)-of-freedom) parallel robot has been studied using a high-precision measuring system. A model of the robot thermal behavior has been built and implemented in the controller. By using it, thermal deformations are compensated in real-time and an absolute accuracy of ±71 nm has been reached. Emanuele Lubrano, Reymond Clavel |
ICRA | 2 |
| 2009 | NanoLab: A nanorobotic system for automated pick-and-place handling and characterization of CNTsabstractCarbon nanotubes (CNTs) are one of the most promising materials for nanoelectronic applications. Before bringing CNTs into large-scale production, a reliable nanorobotic system for automated handling and characterization as well as prototyping of CNT-based components is essential. This paper presents the NanoLab setup, a nanorobotic system that combines specially developed key components such as electrothermal microgrippers and mobile microrobots inside a scanning electron microscope. The working principle and fabrication of mobile microrobots and electrothermal microgripper as well as their interaction and integration is described. Furthermore, the NanoLab is used to explore novel key strategies such as automated locating of CNTs for pick-and-place handling and methods for electrical characterization of CNTs. The results have been achieved within the framework of a European research project where the scientific knowledge will be transfered into an industrial system that will be commercially available for potential customers. Volkmar Eichhorn, Sergej Fatikow, Tim Wortmann, Christian Stolle, Christoph Edeler, Daniel Jasper, Ozlem Sardan, Peter Bøggild, Guillaume Boetsch, Christophe Canales, Reymond Clavel |
ICRA | 11 |
| 2008 | Pelvic motion measurement during over ground walking, analysis and implementation on the WalkTrainer reeducation deviceabstractPelvic motions are of great importance while walking, and have thus to be taken into account when developing and controlling rehabilitation devices. This paper will first introduce a new reeducation device for paraplegic people: the WalkTrainer. This device is composed of a leg and pelvic orthosis, an active bodyweight support and closed loop muscle stimulation. Second, the six degrees of freedom (DOF) of the pelvis will be measured by using the WalkTrainer on a population of twenty healthy subjects. Each DOF was successfully measured and can be analyzed as a function of time or gait cycle. Third several models that predict the pelvic motion amplitude as a function of various parameters (speed, size, ...) will be proposed and analyzed. Fourth, pelvic trajectories will be programmed on the WalkTrainer and applied on healthy subjects by the mean of the pelvic orthosis. In that phase one of the previously proposed models will be implemented. A force reduction of 20% is measured on the pelvic orthosis when the pelvic motion amplitude prediction model is used. At last muscle identification and stimulation will be introduced in the future works chapter. Yves Stauffer, Yves Allemand, Mohamed Bouri, Jacques J. A. Fournier, Reymond Clavel, Patrick Metrailler, Roland Brodard, Fabienne Reynard |
IROS | 5 |
| 2007 | Friction based locomotion module for mobile MEMS robotsabstractThe "modulated friction inertial drive (MFID) principle" is presented as a locomotion solution for mm- size micro robots dealing with both size constraints and limitations in terms of power consumption. Based on one of the configurations of this locomotion principle a locomotion module (10 times 10 mm2) with two degrees of freedom (X, thetasz) has been developed. It consists of two horizontally vibrating masses actuated by electrostatic comb drives and fabricated by DRIE on a SOI wafer. The design as well as calculated and measured actuator displacements and resonance frequencies are presented. First locomotion experiments have shown a linear velocity of 0.207 mm/s for a driving voltage of 30 Vp2pand a power consumption of only 16.6 muW. Walter Driesen, Amar Rida, Jean-Marc Breguet, Reymond Clavel |
IROS | 4 |
| 2004 | Study of the Sources of Inaccuracy of a 3 DOF Flexure Hinge-based Parallel ManipulatorabstractIn this paper a 3 DOF in translation high-precision parallel manipulator having flexure hinges is considered for the purpose of studying its performances in terms of absolute positioning accuracy in presence of different sources of inaccuracy. Manufacturing errors, gravity and temperature gradients are the sources of inaccuracy analyzed by means of FEM simulation models. The obtained data is used to benchmark the different sources studied and to establish a theoretical limit for the positioning performances of the manipulator. The kinematic analysis is performed using simulation models. Tiavina F. Niaritsiry, Nuno Fazenda, Reymond Clavel |
ICRA | 3 |
| 2004 | Shape Memory Alloy Microgripper for Robotic Microassembly of Tissue Engineering ScaffoldsabstractThis paper presents a monolithic shape memory alloy (SMA) microgripper, which was developed to assemble microscopic building blocks of width 60 /spl mu/m into tissue engineering scaffolds. It consists of two small fingers for grasping, an actuator which changes its shape upon heating by Joule effect and a parallel elastic structure to provide a pullback force on cooling as well as to guide the finger movement. All the elements are laser-cut from the same Ni-Ti-Cu sheet but have different mechanical properties and are used for different functions. Using local laser annealing, a local shape memory effect is introduced on the actuator while leaving other areas in a cold-worked state, i.e. no shape memory effect occurs. The material has nonlinear mechanics and the actuator undergoes large deflections. A numerical method is introduced to compute the nonlinear dynamics of the coupled system formed by the actuator and pullback spring. The predicted deflection and force are in good agreement with the measured ones, and this model can be used to optimize the design. Yves Bellouard, Etienne Burdet, Reymond Clavel, Aun Neow Poo, Dietmar Werner Hutmacher |
ICRA | 4 |
| 2002 | Robotic Micro-Assembly of Scaffold/Cell Constructs with a Shape Memory Alloy GripperabstractDescribes an integrated approach to design and fabricate scaffold/cell constructs for tissue engineering. With this approach it becomes possible to produce scaffolds with controlled distribution of living cells and growth factors, a critical condition for successful grafting. Our idea consists of building a scaffold/cell construct by robotic micro-assembly of microscopic polymer building blocks. The paper introduces the rationale and concept of this interdisciplinary project and presents some realized steps. A 3D contact FEM simulation has been carried out to study the forces involved on the scaffold elements and micro-gripper during assembly. An error analysis has been performed to evaluate the accumulated error when building a scaffold/cell construct. A dedicated monolithic shape memory alloy micro-gripper has been realized and tested, which is able to handle parts in the range of 50-100 microns. Etienne Burdet, Dietmar Werner Hutmacher, Aun Neow Poo, Yves Bellouard, Reymond Clavel, Thomas Sidler |
ICRA | 6 |
| 2000 | Issues in Precision Motion Control and MicrohandlingabstractIllustrates with various practical examples an activity at the intersection of MEMS, system control, robotics and ultraprecision design. The resulting new application domains include microrobotics, microfactories and nanotechnologies. Hannes Bleuler, Reymond Clavel, Jean-Marc Breguet, Hans Langen, Eric Pernette |
ICRA | 2 |
| 2000 | Piezoactuators for motion control from centimeter to nanometerabstractThis paper presents several approaches for piezoactuators in motion control over a large dynamic range (cm to nm). The devices include monolithic two-degree-of-freedom actuators with mechanical amplification, stick-slip actuators and 6-DOF designs of micro-positioners. Closed loop feedback is of course necessary for good performance. All the proposed solutions have been realized and experimental results are discussed, application examples in scanning probe microscopy and biology are shortly presented. Jean-Marc Breguet, Arvid Bergander, Carl Schmitt, Reymond Clavel, Hannes Bleuler |
IROS | 5 |
| 1998 | Haptic Interface for Virtual Reality Based Minimally Invasive Surgery SimulationabstractThis paper deals with the mechanical design and control of a novel 4-DOF force-reflecting manual man-machine interface for virtual reality based minimally invasive surgery simulation for training purposes. The realized force feedback manipulator is based on a novel spherical remote-center-of-motion mechanical structure, and features compactness, high sustained output force capability, low friction, zero backlash, and a particularly large, singularity-free workspace. An implicit force control scheme is employed for virtual object impedance simulations. Active compensation of manipulator gravity and actuator friction allows one to simulate static and dynamic object attributes including weight, elasticity, and viscosity over a wide dynamic range of approximately 1:100. Finally, a novel 'supervisory control' concept is proposed which allows one to connect the haptic feedback system to the corresponding graphical simulation environment with highly differing bandwidth requirements. Roger A. Baumann, Reymond Clavel |
ICRA | 2 |
| 1997 | The PantoScope: a spherical remote-center-of-motion parallel manipulator for force reflectionabstractForce reflecting manual man-machine interfaces can provide the user with useful kinesthetic information in teleoperation tasks and virtual reality applications. In this paper we discuss the design of a novel spherical remote-center-of-motion manipulator for force reflection in a laparoscopic surgery simulation environment. A description of the pantograph-linkage based parallel structure is presented together with a discussion of its direct and inverse geometric models, instantaneous kinematics and statics, and usable workspace. Roger A. Baumann, Willy Maeder, Dominique Glauser, Reymond Clavel |
ICRA | 4 |