Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Christopher Siviy

dblp:181/4007 · DBLP profile ↗
← Back
3ranked-venue papers
0as first author
1since 2021 · last 2024
0000-0003-0789-0109ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 3 · 1 since 2021Systems, architecture and hardware · 3 · 1 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Human-computer interaction and pervasive computing
3 papers
Human-robot interaction · 54% Health and well-being technologies · 35% Accessibility and assistive technology · 7%
Artificial intelligence
1 paper
Motion planning and robot control · 100%

Topics — the 10 heaviest of 11, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Human-robot interaction
wearable robot
1.122024
Design & Systematic Evaluation of Power Transmission Efficiency of an Ankle Exoskeleton for Walking Post-Stroke · ICRA 2024
A Lightweight and Efficient Portable Soft Exosuit for Paretic Ankle Assistance in Walking After Stroke · ICRA 2018
Human-robot interaction › wearable robot › exoskeleton
ankle exoskeleton
0.812024
Design & Systematic Evaluation of Power Transmission Efficiency of an Ankle Exoskeleton for Walking Post-Stroke · ICRA 2024
Health and well-being technologies › rehabilitation technology
post-stroke gait rehabilitation
0.812024
Design & Systematic Evaluation of Power Transmission Efficiency of an Ankle Exoskeleton for Walking Post-Stroke · ICRA 2024
Health and well-being technologies
rehabilitation technology
0.812024
Design & Systematic Evaluation of Power Transmission Efficiency of an Ankle Exoskeleton for Walking Post-Stroke · ICRA 2024
Human-robot interaction › wearable robot
soft exosuit
0.622018
A Lightweight and Efficient Portable Soft Exosuit for Paretic Ankle Assistance in Walking After Stroke · ICRA 2018
IMU-based iterative control for hip extension assistance with a soft exosuit · ICRA 2016
Robotics › Motion planning and robot control › robot control
exoskeleton control
0.312018
A Lightweight and Efficient Portable Soft Exosuit for Paretic Ankle Assistance in Walking After Stroke · ICRA 2018
Accessibility and assistive technology
assistive technology
0.312018
A Lightweight and Efficient Portable Soft Exosuit for Paretic Ankle Assistance in Walking After Stroke · ICRA 2018
Human-robot interaction
physical human-robot interaction
0.212016
IMU-based iterative control for hip extension assistance with a soft exosuit · ICRA 2016
Health and well-being technologies › rehabilitation technology › rehabilitation robotics
gait rehabilitation
0.112018
A Lightweight and Efficient Portable Soft Exosuit for Paretic Ankle Assistance in Walking After Stroke · ICRA 2018
Health and well-being technologies
rehabilitation
0.112018
A Lightweight and Efficient Portable Soft Exosuit for Paretic Ankle Assistance in Walking After Stroke · ICRA 2018

Methods — techniques the papers use, named apart from their topics

walking trials · 0.8systematic power loss quantification · 0.8biomechanical assessment · 0.7assistive force control · 0.7iterative control · 0.2gait detection · 0.2IMU-based state estimation · 0.2
YearPublicationVenuePosition
2024 Design & Systematic Evaluation of Power Transmission Efficiency of an Ankle Exoskeleton for Walking Post-Stroke
abstract
Community-based locomotor training post-stroke has shown improvements in independent ambulation by increasing dose, intensity, and specificity of walking practice. Robotic ankle exoskeletons hold the potential to facilitate continued rehabilitation at home, but understanding what aspects of the design are most relevant for successful translation to the community presents a challenge. Here, we design a portable rigid ankle exoskeleton to use as a research platform for investigating the effect of assistance on post-stroke gait during overground, community-based walking. We first test our device with stroke survivors and validate its potential for future community use. We then present a systematic method for quantifying power transmission losses at each transmission stage from the battery to the wearer, using data gathered from walking trials with healthy participants. Our evaluation method revealed inefficiencies in power transfer at the interface level, likely resulting from the compliance in the structural components of the system, which motivates future redesign considerations. Overall, our method provides a framework to identify and characterize the components that must be redesigned to lower exoskeleton weight and maximize performance.
Myles Cooper, Santiago Canete, Asa M. Eckert-Erdheim, Aidan Kimberley, Christopher Siviy, Teresa Baker, Terry Ellis, Patrick Slade, Conor J. Walsh
ICRA5
2018 A Lightweight and Efficient Portable Soft Exosuit for Paretic Ankle Assistance in Walking After Stroke
abstract
Hemiparetic gait after stroke is typically asymmetric and energetically inefficient. A major contributor to walking deficits is impaired paretic ankle function. Impaired paretic ankle plantarflexion (PF) reduces forward propulsion symmetry and impaired paretic ankle dorsiflexion (DF) diminishes ground clearance during swing. We have developed soft wearable robots (soft exosuits) to assist paretic PF and DF during walking after stroke. Through experimental studies with poststroke patients, we have demonstrated that exosuits can improve forward propulsion symmetry and ground clearance in walking, ultimately reducing the metabolic cost of walking. This paper presents an optimized soft exosuit aimed at use in clinical gait training for patients poststroke. The optimized exosuit is lightweight, easy to don and doff, and capable of efficiently delivering mechanical assistance to the paretic ankle. This paper focuses on the optimized controller that can deliver well-timed consistent ankle assistance to patients. A preliminary study was performed using this exosuit with three poststroke patients with heterogeneous gait patterns. Results showed that compared to a previously published controller, more consistent assistive force profiles could be delivered to individuals poststroke while consuming 50% less electrical power. Additionally, a preliminary biomechanical assessment was performed during overground walking.
Jaehyun Bae, Christopher Siviy, Michael Rouleau, Nicolas Menard, Kathleen O'Donnell, Ignacio Galiana, Maria Athanassiu, Danielle Ryan, Christine Bibeau, Lizeth Sloot, Pawel Kudzia, Terry Ellis, Louis Awad, Conor J. Walsh
ICRA2
2016 IMU-based iterative control for hip extension assistance with a soft exosuit
abstract
In this paper we describe an IMU-based iterative controller for hip extension assistance where the onset timing of assistance is based on an estimate of the maximum hip flexion angle. The controller was implemented on a mono-articular soft exosuit coupled to a lab-based multi-joint actuation platform that enables rapid reconfiguration of different sensors and control strategy implementation. The controller design is motivated by a model of the suit-human interface and utilizes an iterative control methodology that includes gait detection and step-by-step actuator position profile generation to control the onset timing, peak timing, and peak magnitude of the delivered force. This controller was evaluated on eight subjects walking on a treadmill at a speed of 1.5 m/s while carrying a load of 23 kg. Results showed that assistance could be delivered reliably across subjects. Specifically, for a given profile, the average delivered force started concurrently with the timing of the maximum hip flexion angle and reached its peak timing 22.7 ± 0.63% later in the gait cycle (desired 23%) with a peak magnitude of 198.2 ± 1.6 N (desired 200 N), equivalent to an average peak torque of 30.5 ± 4.7 Nm. This control approach was used to assess the metabolic effect of four different assistive profiles. Metabolic reductions ranging from 5.7% to 8.5% were found when comparing the powered conditions with the unpowered condition. This work enables studies to assess the biomechanical and physiological responses to different assistive profiles to determine the optimal hip extension assistance during walking.
Ignacio Galiana, Christopher Siviy, Fausto A. Panizzolo, Conor J. Walsh
ICRA3