Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Samuel Frishman

dblp:203/5426 · DBLP profile ↗
← Back
3ranked-venue papers
1as first author
2since 2021 · last 2025
0000-0003-2047-9875ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 3 · 1 first-author · 2 since 2021Systems, architecture and hardware · 3 · 1 first-author · 2 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
2 papers
Robot manipulation · 100%
Interdisciplinary, comprehensive, and emerging computing
2 papers
Medical and health informatics · 100%
Human-computer interaction and pervasive computing
1 paper
Haptics and multimodal interaction · 100%

Topics — the 5 heaviest of 6, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation › actuator design
cable-driven transmission
0.912025
Design and Evaluation of High-Performance Motion-Decoupled Cable Transmission Modules · ICRA 2025
Robotics › Robot manipulation
robot actuation
0.912025
Design and Evaluation of High-Performance Motion-Decoupled Cable Transmission Modules · ICRA 2025
Robotics › Robot manipulation › medical robotics
needle insertion
0.312017
A rolling-diaphragm hydrostatic transmission for remote MR-guided needle insertion · ICRA 2017
Medical and health informatics › surgical robotics
robot-assisted surgery
0.312025
Design and Evaluation of High-Performance Motion-Decoupled Cable Transmission Modules · ICRA 2025
Medical and health informatics › image-guided intervention
MRI-guided intervention
0.112017
A rolling-diaphragm hydrostatic transmission for remote MR-guided needle insertion · ICRA 2017

Methods — techniques the papers use, named apart from their topics

rolling-plus-twist joint design · 1.7ball-bearing supported cable capstan · 1.7rolling-diaphragm hydrostatic transmission · 0.9cable-capstan drive · 0.9
YearPublicationVenuePosition
2025 Design and Evaluation of High-Performance Motion-Decoupled Cable Transmission Modules
abstract
Cable transmissions are commonly used in robotics for remote force transmission, offering a lightweight, compact, and efficient solution for transmitting high forces between input and output. However, cables in flexible compression housings (Bowden cables), exhibit high static friction, which increases exponentially with total bend angle. Alternatively, internally routed ball-bearing supported cable capstan transmissions are low friction, but complex and present challenges in routing multiple sets of cables. In this paper, we propose motion-decoupled cable transmission modules that address these challenges, occupying the middle ground, functioning as discrete-joint ball-bearing supported Bowden cables. Our rolling-plus-twist joint design decouples pairs of routed cables from changing significantly in tension, length, or friction during large angle motion of the linked transmission. Using sub-1 mm diameter high-strength synthetic cable, the transmission exhibits a maximum coupling motion of only 0.15 mm over the full range of motion of the cable-transmission mechanism, approximately 10% of pretension in combined hysteresis and friction, a transmission stiffness of 10 N/mm, weighing just 9 g per rolling joint and 5 g per twist joint. Two applications are demonstrated: cable routing alongside a robot arm for, say, gripper remote actuation, and remote needle advancement for an MRI-safe needle biopsy robot.
Ryo Takei, Samuel Frishman, John Peter Whitney
ICRA2
2021 A Multi-Axis FBG-Based Tactile Sensor for Gripping in Space
abstract
Tactile sensing can improve end-effector control and grasp quality, especially for free-flying robots where target approach and alignment present particular challenges. However, many current tactile sensing technologies are not suitable for the harsh environment of space. We present a tactile sensor that measures normal and biaxial shear strains in the pads of a gripper using a single optical fiber with Bragg grating (FBG) sensors. Compared to conventional wired solutions, the encapsulated optical fibers are immune to electromagnetic interference — critical in the harsh environment of space. Sampling is possible at over 1 kHz to detect dynamic events. We mount sensor pads on a custom two-fingered gripper with independent control of the distal and proximal phalanges, allowing for grip readjustment based on sensing data. Calibrated sensor data for forces match those from a commercial multiaxial load cell with an average 96.2% RMS for all taxels. We demonstrate the gripper on tasks motivated by the Astrobee free-flying robots in the International Space Station (ISS): gripping corners, detecting misaligned grasps, and improving load sharing over the contact areas in pinch grasps.
Samuel Frishman, Julia Di, Zulekha Karachiwalla, Richard J. Black, Kian Moslehi, Trey Smith, Brian Coltin, Bijan Moslehi, Mark R. Cutkosky
IROS1
2017 A rolling-diaphragm hydrostatic transmission for remote MR-guided needle insertion
abstract
Magnetic resonance imaging (MRI) offers many benefits, including unsurpassed soft-tissue characterization and the ability to combine detection and biopsy into a single procedure. However, limited patient access in the narrow scanner bore requires tedious iterative positioning or use of robotic assistants that isolate the physician from the patient. As an alternative, we present a teleoperation technology for percutaneous procedures to meet the needs of interventional radiologists and overcome challenges imposed by the MR environment. The technology is demonstrated for a 1-DOF needle insertion procedure. The technology uses rolling diaphragms, a clutch, and a cable-capstan drive to propel the needle while relaying forces and motions to the operator. The system demonstrates excellent position tracking (< 0.7° error in the unloaded case) and reliably transmits changes in force. During needle teleoperation, users were able to detect light membrane punctures and differentiate spring stiffnesses nearly as accurately as by hand manipulation.
Natalie Burkhard, Samuel Frishman, Alexander Gruebele, John Peter Whitney, Roger E. Goldman, Bruce Lewis Daniel, Mark R. Cutkosky
ICRA2