Demo Data from VLDB 2026 / reviewers in the wild / expert
Samuel Frishman
dblp:203/5426
· DBLP profile ↗
3ranked-venue papers
1as first author
2since 2021 · last 2025
0000-0003-2047-9875ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 3 · 1 first-author · 2 since 2021Systems, architecture and hardware · 3 · 1 first-author · 2 since 2021
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
2 papers |
Robot manipulation · 100% | |
| Interdisciplinary, comprehensive, and emerging computing
2 papers |
Medical and health informatics · 100% | |
| Human-computer interaction and pervasive computing
1 paper |
Haptics and multimodal interaction · 100% |
Topics — the 5 heaviest of 6, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Robot manipulation › actuator design
cable-driven transmission |
0.9 | 1 | 2025 | Design and Evaluation of High-Performance Motion-Decoupled Cable Transmission Modules · ICRA 2025 |
Robotics › Robot manipulation
robot actuation |
0.9 | 1 | 2025 | Design and Evaluation of High-Performance Motion-Decoupled Cable Transmission Modules · ICRA 2025 |
Robotics › Robot manipulation › medical robotics
needle insertion |
0.3 | 1 | 2017 | A rolling-diaphragm hydrostatic transmission for remote MR-guided needle insertion · ICRA 2017 |
Medical and health informatics › surgical robotics
robot-assisted surgery |
0.3 | 1 | 2025 | Design and Evaluation of High-Performance Motion-Decoupled Cable Transmission Modules · ICRA 2025 |
Medical and health informatics › image-guided intervention
MRI-guided intervention |
0.1 | 1 | 2017 | A rolling-diaphragm hydrostatic transmission for remote MR-guided needle insertion · ICRA 2017 |
Methods — techniques the papers use, named apart from their topics
rolling-plus-twist joint design · 1.7ball-bearing supported cable capstan · 1.7rolling-diaphragm hydrostatic transmission · 0.9cable-capstan drive · 0.9
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2025 | Design and Evaluation of High-Performance Motion-Decoupled Cable Transmission ModulesabstractCable transmissions are commonly used in robotics for remote force transmission, offering a lightweight, compact, and efficient solution for transmitting high forces between input and output. However, cables in flexible compression housings (Bowden cables), exhibit high static friction, which increases exponentially with total bend angle. Alternatively, internally routed ball-bearing supported cable capstan transmissions are low friction, but complex and present challenges in routing multiple sets of cables. In this paper, we propose motion-decoupled cable transmission modules that address these challenges, occupying the middle ground, functioning as discrete-joint ball-bearing supported Bowden cables. Our rolling-plus-twist joint design decouples pairs of routed cables from changing significantly in tension, length, or friction during large angle motion of the linked transmission. Using sub-1 mm diameter high-strength synthetic cable, the transmission exhibits a maximum coupling motion of only 0.15 mm over the full range of motion of the cable-transmission mechanism, approximately 10% of pretension in combined hysteresis and friction, a transmission stiffness of 10 N/mm, weighing just 9 g per rolling joint and 5 g per twist joint. Two applications are demonstrated: cable routing alongside a robot arm for, say, gripper remote actuation, and remote needle advancement for an MRI-safe needle biopsy robot. Ryo Takei, Samuel Frishman, John Peter Whitney |
ICRA | 2 |
| 2021 | A Multi-Axis FBG-Based Tactile Sensor for Gripping in SpaceabstractTactile sensing can improve end-effector control and grasp quality, especially for free-flying robots where target approach and alignment present particular challenges. However, many current tactile sensing technologies are not suitable for the harsh environment of space. We present a tactile sensor that measures normal and biaxial shear strains in the pads of a gripper using a single optical fiber with Bragg grating (FBG) sensors. Compared to conventional wired solutions, the encapsulated optical fibers are immune to electromagnetic interference — critical in the harsh environment of space. Sampling is possible at over 1 kHz to detect dynamic events. We mount sensor pads on a custom two-fingered gripper with independent control of the distal and proximal phalanges, allowing for grip readjustment based on sensing data. Calibrated sensor data for forces match those from a commercial multiaxial load cell with an average 96.2% RMS for all taxels. We demonstrate the gripper on tasks motivated by the Astrobee free-flying robots in the International Space Station (ISS): gripping corners, detecting misaligned grasps, and improving load sharing over the contact areas in pinch grasps. Samuel Frishman, Julia Di, Zulekha Karachiwalla, Richard J. Black, Kian Moslehi, Trey Smith, Brian Coltin, Bijan Moslehi, Mark R. Cutkosky |
IROS | 1 |
| 2017 | A rolling-diaphragm hydrostatic transmission for remote MR-guided needle insertionabstractMagnetic resonance imaging (MRI) offers many benefits, including unsurpassed soft-tissue characterization and the ability to combine detection and biopsy into a single procedure. However, limited patient access in the narrow scanner bore requires tedious iterative positioning or use of robotic assistants that isolate the physician from the patient. As an alternative, we present a teleoperation technology for percutaneous procedures to meet the needs of interventional radiologists and overcome challenges imposed by the MR environment. The technology is demonstrated for a 1-DOF needle insertion procedure. The technology uses rolling diaphragms, a clutch, and a cable-capstan drive to propel the needle while relaying forces and motions to the operator. The system demonstrates excellent position tracking (< 0.7° error in the unloaded case) and reliably transmits changes in force. During needle teleoperation, users were able to detect light membrane punctures and differentiate spring stiffnesses nearly as accurately as by hand manipulation. Natalie Burkhard, Samuel Frishman, Alexander Gruebele, John Peter Whitney, Roger E. Goldman, Bruce Lewis Daniel, Mark R. Cutkosky |
ICRA | 2 |