Demo Data from VLDB 2026 / reviewers in the wild / expert
Benjamin Filtjens
dblp:218/7658
· DBLP profile ↗
4ranked-venue papers
1as first author
3since 2021 · last 2026
0000-0003-2609-6883ORCID · verified
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 2 · 1 since 2021Graphics, computer vision, multimedia, augmented reality and games · 2 · 1 since 2021Applied, interdisciplinary, general and emerging computing · 2 · 1 first-author · 1 since 2021
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% | |
| Artificial intelligence
1 paper |
3D vision · 100% | |
| Human-computer interaction and pervasive computing
1 paper |
Health and well-being technologies · 100% |
Topics — the 3 heaviest of 4, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Computer vision › 3D vision
human mesh recovery |
0.9 | 1 | 2025 | Care-PD: A Multi-Site Anonymized Clinical Dataset for Parkinson's Disease Gait Assessment · NeurIPS 2025 |
Medical and health informatics
gait analysis |
0.9 | 1 | 2025 | Care-PD: A Multi-Site Anonymized Clinical Dataset for Parkinson's Disease Gait Assessment · NeurIPS 2025 |
Medical and health informatics
parkinson's disease |
0.9 | 1 | 2025 | Care-PD: A Multi-Site Anonymized Clinical Dataset for Parkinson's Disease Gait Assessment · NeurIPS 2025 |
Methods — techniques the papers use, named apart from their topics
motion encoder · 2.6keypoint lifting · 2.6
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2026 | GAITGen: Disentangled Motion-Pathology Impaired Gait Generative Model - Bringing Motion Generation to the Clinical DomainabstractGait analysis is crucial for the diagnosis and monitoring of movement disorders like Parkinson's Disease. While computer vision models have shown potential for objectively evaluating parkinsonian gait, their effectiveness is limited by scarce clinical datasets and the challenge of collecting large and well-labelled data, impacting model accuracy and risk of bias. To address these gaps, we propose GAITGen, a novel framework that generates realistic gait sequences conditioned on specified pathology severity levels. GAITGen employs a Conditional Residual Vector Quantized Variational Autoencoder to learn disentangled representations of motion dynamics and pathology-specific factors, coupled with Mask and Residual Transformers for conditioned sequence generation. GAITGen generates realistic, diverse gait sequences across severity levels, enriching datasets and enabling large-scale model training in parkinsonian gait analysis. Experiments on our new PD-GaM (real) dataset demonstrate that GAITGen outperforms adapted state-of-the-art models in both reconstruction fidelity and generation quality, accurately capturing critical pathology-specific gait features. A clinical user study confirms the realism and clinical relevance of our generated sequences. Moreover, incorporating GAITGen-generated data into downstream tasks improves parkinsonian gait severity estimation, highlighting its potential for advancing clinical gait analysis. Vida Adeli, Soroush Mehraban, Majid Mirmehdi, Alan L. Whone, Benjamin Filtjens, Amirhossein Dadashzadeh, Alfonso Fasano, Andrea Iaboni, Babak Taati |
WACV | 5 |
| 2025 | Care-PD: A Multi-Site Anonymized Clinical Dataset for Parkinson's Disease Gait AssessmentabstractObjective gait assessment in Parkinson’s Disease (PD) is limited by the absence of large, diverse, and clinically annotated motion datasets. We introduce Care-PD, the largest publicly available archive of 3D mesh gait data for PD, and the first multi-site collection spanning 9 cohorts from 8 clinical centers. All recordings (RGB video or motion capture) are converted into anonymized SMPL meshes via a harmonized preprocessing pipeline. Care-PD supports two key benchmarks: supervised clinical score prediction (estimating Unified Parkinson’s Disease Rating Scale, UPDRS, gait scores) and unsupervised motion pretext tasks (2D-to-3D keypoint lifting and full-body 3D reconstruction). Clinical prediction is evaluated under four generalization protocols: within-dataset, cross-dataset, leave-one-dataset-out, and multi-dataset in-domain adaptation.To assess clinical relevance, we compare state-of-the-art motion encoders with a traditional gait-feature baseline, finding that encoders consistently outperform handcrafted features. Pretraining on Care-PD reduces MPJPE (from 60.8mm to 7.5mm) and boosts PD severity macro-F1 by 17\%, underscoring the value of clinically curated, diverse training data. Care-PD and all benchmark code are released for non-commercial research (Code, Data). Vida Adeli, Ivan Klabucar, Javad Rajabi, Benjamin Filtjens, Soroush Mehraban, Diwei Wang, Trung-Hieu Hoang, Minh N. Do, Hyewon Seo, Candice Müller, Daniel Boari Coelho, Claudia de Oliveira, Pieter Ginis, Moran Gilat, Alice Nieuwboer, Joke Spildooren, J. Lucas McKay, Hyeokhyen Kwon, Gari D. Clifford, Christine D. Esper, Stewart A. Factor, Imari Genias, Amirhossein Dadashzadeh, Leia C. Shum, Alan L. Whone, Majid Mirmehdi, Andrea Iaboni, Babak Taati |
NeurIPS | 4 |
| 2023 | Automated freezing of gait assessment with deep learning and data augmentation from simulated inertial measurement unit dataabstractFreezing of gait (FOG) is a common and severe symptom of Parkinson’s disease (PD). Due to the complex underlying pathophysiology, FOG is difficult to assess, hampering further insight into this phenomenon. Inertial measurement units (IMUs) may enable FOG assessment during everyday life, but lack of standardization, e.g., the number and position of the IMUs, complicates an objective comparison of automatic FOG assessment algorithms. We propose a multi-stage temporal dilated convolutional model to automatically assess FOG based on IMU data. We collected simultaneous optical motion capture (MoCap) and IMU data of ten people with PD and FOG. We devised a simulation pipeline, i.e., generating IMU data from MoCap data, to objectively compare our approach to two state-of-the-art FOG assessment models. The comparison was performed for five simulated IMU configurations, ranging from 1 to 7 IMUs. The results show that our approach outperforms the two state-of-the-art methods on most of the simulated IMU configurations. The complete lower-body IMU setup of 7 IMUs (pelvis and both sides of the talus, tibia, and femur) enables the best FOG detection performance. Lastly, we show that our model trained by incorporating simulated IMU data enabled significantly improved FOG detection performance than our model trained only with real IMU data. In doing so, we demonstrate that retrospective MoCap datasets can be re-used to train expressive IMU-based FOG assessment models, reducing the required amount of dedicated and labor-intensive IMU data collection experiments. Benjamin Filtjens, Po-Kai Yang, Maaike Goris, Moran Gilat, Niklas Kempynck, Pieter Ginis, Alice Nieuwboer, Peter Slaets, Bart Vanrumste |
BSN | 1 |
| 2018 | Dynamic Gait Monitoring Mobile PlatformabstractHuman gait is an important indicator of health. Existing gait analysis systems are either expensive, intrusive, or require structured environments such as a clinic or a laboratory. In this research, a low-cost, non-obtrusive, dynamic gait monitoring platform is presented. By utilizing a mobile robot equipped with a Kinect sensor, comprehensive gait information can be extracted. The mobile platform tracks the skeletal joint movements while following the person. The acquired skeletal joint data is filtered to improve detection. Gait parameters such as step length, cadence and gait cycle time are extracted by processing the filtered data. The proposed approach was validated by using a VICON motion capture system. Results show that the proposed system is able to accurately detect gait parameters but requires a calibration procedure. Even though the camera is moving while tracking, the performance is on par with existing works. Step times can be detected with an average accuracy of around 10 milliseconds. Step length can be detected with an average accuracy of a few centimeters. Robin Amsters, Ali Bin Junaid, Nick Damen, Jeroen Van de Laer, Benjamin Filtjens, Bart Vanrumste, Peter Slaets |
ICT4AWE | 5 |