Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Ton T. H. Duong

dblp:246/1073 · DBLP profile ↗
← Back
2ranked-venue papers
2as first author
1since 2021 · last 2021
0000-0002-2529-5875ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 2 · 2 first-author · 1 since 2021Systems, architecture and hardware · 2 · 2 first-author · 1 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Human-computer interaction and pervasive computing
1 paper
Wearable and physiological sensing · 100%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 1 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics
assistive technology
0.112020
An Outsole-Embedded Optoelectronic Sensor to Measure Shear Ground Reaction Forces During Locomotion · ICRA 2020

Methods — techniques the papers use, named apart from their topics

optoelectronic sensing · 0.9inverse dynamics · 0.9
YearPublicationVenuePosition
2021 Gaussian Process Regression for COP Trajectory Estimation in Healthy and Pathological Gait Using Instrumented Insoles
abstract
Research in powered prostheses and orthoses has relied on COP measurements to inform a device’s controller about the body’s progression through the gait cycle, and to provide sensory substitution for prosthesis users, thereby helping them maintain balance during locomotion. Obtaining accurate COP measurements in out-of-the-lab contexts currently requires pressure sensitive insoles with dense arrays of sensing elements, which are expensive and bulky, limiting the accessibility and scalability of this technology. In this paper, we present a new method to reconstruct COP trajectories in over-ground walking tasks, using an affordable sensor array with eight sensing elements embedded in shoe insoles. The method leverages Gaussian Process Regression (GPR) to perform predictions from raw sensor data using Bayesian inference. A preliminary validation was carried out with a convenience sample of healthy individuals and patients with neuromuscular disorders. Combined mediolateral (ML) and anteroposterior (AP) errors where 2% and 3% for healthy individuals and patients, respectively. The analysis evidenced larger stride-to-stride variability in the ML COP excursion for the patient group, suggesting higher levels of motor noise associated with selective muscle weakness. These promising results indicate the potential of the proposed method to accurately estimate COP trajectories for future applications in wearable robotics and out-of-the-lab clinical gait assessments.
Ton T. H. Duong, David Uher, Sally Dunaway Young, Tina Duong, Monica Sangco, Kayla M. Cornett, Jacqueline Montes, Damiano Zanotto
IROS1
2020 An Outsole-Embedded Optoelectronic Sensor to Measure Shear Ground Reaction Forces During Locomotion
abstract
Online estimation of 3D ground reaction forces (GRFs) is becoming increasingly important for closed-loop control of lower-extremity robotic exoskeletons. Through in-verse dynamics and optimization models, 3D GRFs can be used to estimate net joint torques and approximate muscle forces. Although instrumented footwear to measure vertical GRFs in out-of-the-lab environments is available, accurately measuring shear GRFs with foot-mounted sensors still remains a challenging task. In this paper, a new outsole-embedded optoelectronic sensor configuration that is able to measure biaxial shear GRFs is proposed. Compared with traditional strain-gauge based solutions, optoelectronic sensors allow for a more affordable design. To mitigate the risk of altering the wearer's natural gait, the proposed solution does not involve external modifications to the footwear structure. A preliminary validation of the outsole-embedded sensor was conducted against validated laboratory equipment. The test involved two sessions of treadmill walking at different speeds. Experimental results suggest that the proposed design may be a promising solution for measuring shear GRFs in unconstrained environments.
Ton T. H. Duong, David R. Whittaker, Damiano Zanotto
ICRA1