VLDB 2026 Research / reviewers in the wild / expert
Yang Li 0147
dblp:37/4190-147
· DBLP profile ↗
10ranked-venue papers
3as first author
3since 2021 · last 2026
0000-0002-0744-4996ORCID · conflict
Domains — the database's venue-derived domains; a paper can count in several
Computer networks · 10 · 3 first-author · 3 since 2021
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Human-computer interaction and pervasive computing
7 papers |
Health and well-being technologies · 36% Wearable and physiological sensing · 34% Ubiquitous computing and smart environments · 29% | |
| Computer networks
5 papers |
Wireless sensing and localization · 64% Internet of things and sensor networks · 36% | |
| Artificial intelligence
2 papers |
Efficient and distributed learning · 82% Robot navigation and mapping · 18% | |
| Computer graphics and multimedia
1 paper |
Multimedia analysis and retrieval · 100% | |
| Network and information security
1 paper |
Authentication and access control · 100% | |
| Computer architecture, parallel and distributed computing, and storage systems
1 paper |
Distributed systems · 100% |
Topics — the 16 heaviest of 20, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Multimedia analysis and retrieval
multimodal action understanding |
1.0 | 1 | 2026 | A Large-Scale Multimodal Dataset and Benchmarks for Human Activity Scene Understanding and Reasoning · MobiSys 2026 |
Ubiquitous computing and smart environments › context recognition
activity recognition |
1.0 | 1 | 2026 | A Large-Scale Multimodal Dataset and Benchmarks for Human Activity Scene Understanding and Reasoning · MobiSys 2026 |
Machine learning › Efficient and distributed learning
federated learning |
0.8 | 1 | 2024 | ADMarker: A Multi-Modal Federated Learning System for Monitoring Digital Biomarkers of Alzheimer's Disease · MobiCom 2024 |
Machine learning › Efficient and distributed learning › federated learning
multimodal federated learning |
0.8 | 1 | 2024 | ADMarker: A Multi-Modal Federated Learning System for Monitoring Digital Biomarkers of Alzheimer's Disease · MobiCom 2024 |
Health and well-being technologies
dementia care |
0.8 | 1 | 2024 | Demo: EmoMarker: A Privacy-Preserving, Multi-Modal Sensing System for Dyadic Digital Biomarkers of Expressed Emotions for Patients with Dementia · MobiSys 2024 |
Health and well-being technologies › digital phenotyping
digital biomarkers |
0.8 | 1 | 2024 | ADMarker: A Multi-Modal Federated Learning System for Monitoring Digital Biomarkers of Alzheimer's Disease · MobiCom 2024 |
Authentication and access control
device authentication |
0.4 | 1 | 2019 | Towards Touch-to-Access Device Authentication Using Induced Body Electric Potentials · MobiCom 2019 |
Authentication and access control › device pairing
touch-to-access pairing |
0.4 | 1 | 2019 | Towards Touch-to-Access Device Authentication Using Induced Body Electric Potentials · MobiCom 2019 |
Distributed systems
clock synchronization |
0.4 | 1 | 2019 | Wearables Clock Synchronization Using Skin Electric Potentials · IEEE Trans. Mob. Comput. 2019 |
Internet of things and sensor networks
wireless sensor network |
0.4 | 2 | 2017 | Natural timestamping using powerline electromagnetic radiation · IPSN 2017 Natural timestamping using electrical power grid: demo abstract · IPSN 2017 |
Robotics › Robot navigation and mapping
SLAM |
0.3 | 1 | 2018 | Simultaneous Localization and Mapping with Power Network Electromagnetic Field · MobiCom 2018 |
Wireless sensing and localization
electromagnetic field sensing |
0.3 | 1 | 2018 | Simultaneous Localization and Mapping with Power Network Electromagnetic Field · MobiCom 2018 |
Wireless sensing and localization
indoor localization |
0.3 | 1 | 2018 | Simultaneous Localization and Mapping with Power Network Electromagnetic Field · MobiCom 2018 |
Wearable and physiological sensing › motion sensing
IMU sensing |
0.3 | 1 | 2026 | A Large-Scale Multimodal Dataset and Benchmarks for Human Activity Scene Understanding and Reasoning · MobiSys 2026 |
Internet of things and sensor networks
time synchronization |
0.3 | 1 | 2017 | Natural timestamping using powerline electromagnetic radiation · IPSN 2017 |
Wearable and physiological sensing
multimodal sensing |
0.2 | 1 | 2024 | Demo: EmoMarker: A Privacy-Preserving, Multi-Modal Sensing System for Dyadic Digital Biomarkers of Expressed Emotions for Patients with Dementia · MobiSys 2024 |
Methods — techniques the papers use, named apart from their topics
prompt-based caption generation · 2.0multimodal large vision-language models · 2.0multimodal sensing · 1.5federated learning · 1.5network time protocol · 1.3integer ambiguity resolution · 1.3induced body electric potentials · 1.1analog-to-digital conversion · 1.1online localization · 1.0loop closure detection · 1.0sensor sampling · 0.3electromagnetic radiation conditioning · 0.3electric network frequency fluctuation analysis · 0.3electric network frequency extraction · 0.3
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2026 | A Large-Scale Multimodal Dataset and Benchmarks for Human Activity Scene Understanding and ReasoningabstractMultimodal human action recognition (HAR) utilizes complementary data for activity classification. Built on traditional HAR tasks, recent advances in Large Language Models (LLMs) enable detailed descriptions and causal reasoning of human actions, advancing new tasks of human action understanding (HAU) and human action reasoning (HARn). However, most LLMs, especially multimodal Large Vision-Language Models (LVLMs), struggle with modalities other than RGB images, like depth, IMU, ormmWave, due to a lack of large-scale datasets in these task domains. Existing HAR datasets provide only coarse-grained annotations, in-sufficient for depicting the detailed action dynamics required in HAU and HARn tasks. Simply combining annotations and generating captions with LLMs often lacks necessary logical and spatiotemporal consistency. In this paper, we introduce CUHK-X, a large-scale multi-modal dataset and benchmarks for HAR, HAU, and HARn. It includes 64,267 samples of 40 actions performed by 30 participants across two indoor environments, covering diverse daily scenarios. To address the challenge of spatiotemporal inconsistencies in captions, we propose a prompt-based scene creation method that leverages LLMs to generate logically connected activity sequences. CUHK-X also includes three benchmarks with six tasks to evaluate state-of-the-art models. Experimental results show average accuracies of 76.52% for HAR, 40.76% for HAU, and 70.25% for HARn. This large-scale multimodal dataset aims to empower the research community to apply, develop, and adapt data-intensive learning techniques for a wide range of human activity-related tasks. Siyang Jiang, Mu Yuan, Bufang Yang, Lilin Xu, Yang Li 0147, Yuting He 0006, Liran Dong, Wenrui Lu, Zhenyu Yan 0002, Xiaofan Jiang 0001, Wei Gao 0006, Hongkai Chen 0001, Guoliang Xing |
MobiSys | 7 |
| 2024 | ADMarker: A Multi-Modal Federated Learning System for Monitoring Digital Biomarkers of Alzheimer's DiseaseabstractAlzheimer's Disease (AD) and related dementia are a growing global health challenge due to the aging population. In this paper, we present ADMarker, the first end-to-end system that integrates multi-modal sensors and new federated learning algorithms for detecting multidimensional AD digital biomarkers in natural living environments. ADMarker features a novel three-stage multi-modal federated learning architecture that can accurately detect digital biomarkers in a privacy-preserving manner. Our approach collectively addresses several major real-world challenges, such as limited data labels, data heterogeneity, and limited computing resources. We built a compact multi-modality hardware system and deployed it in a four-week clinical trial involving 91 elderly participants. The results indicate that ADMarker can accurately detect a comprehensive set of digital biomarkers with up to 93.8% accuracy and identify early AD with an average of 88.9% accuracy. ADMarker offers a new platform that can allow AD clinicians to characterize and track the complex correlation between multidimensional interpretable digital biomarkers, demographic factors of patients, and AD diagnosis in a longitudinal manner. Xiaomin Ouyang, Xian Shuai, Yang Li 0147, Li Pan 0004, Xifan Zhang, Heming Fu, Sitong Cheng, Xinyan Wang 0003, Shihua Cao, Jiang Xin, Hazel Mok, Zhenyu Yan 0002, Doris Sau-Fung Yu, Timothy Kwok, Guoliang Xing |
MobiCom | 3 |
| 2024 | Demo: EmoMarker: A Privacy-Preserving, Multi-Modal Sensing System for Dyadic Digital Biomarkers of Expressed Emotions for Patients with DementiaabstractAlzheimer's disease and related dementia has emerged as a global health challenge due to aging population. Expressed Emotion (EE) is a widely-used medical measure of family emotional environment of patients with caregivers. We present EmoMarker, a multi-modal sensor detection system for dyadic digital biomarkers of EE in dementia patients' homes. EmoMarker consists of a privacy-preserving depth camera and a microphone to extracts interpretable dyadic (i.e., motor and acoustic) digital biomarkers of the interaction between patients and caregivers and predict the scores of Family Altitude Scale, an assessment tool for measuring the emotional climate of families. We have deployed our system in 99 elder people's homes and achieved 81.13% prediction accuracy in preliminary results. Yang Li 0147, Doris Sau-Fung Yu, Shuangzhou Chen, Guoliang Xing, Hongkai Chen 0001 |
MobiSys | 1 |
| 2019 | Towards Touch-to-Access Device Authentication Using Induced Body Electric PotentialsabstractThis paper presents TouchAuth, a new touch-to-access device authentication approach using induced body electric potentials (iBEPs) caused by the indoor ambient electric field that is mainly emitted from the building's electrical cabling. The design of TouchAuth is based on the electrostatics of iBEP generation and a resulting property, i.e., the iBEPs at two close locations on the same human body are similar, whereas those from different human bodies are distinct. Extensive experiments verify the above property and show that TouchAuth achieves high-profile receiver operating characteristics in implementing the touch-to-access policy. Our experiments also show that a range of possible interfering sources including appliances' electromagnetic emanations and noise injections into the power network do not affect the performance of TouchAuth. A key advantage of TouchAuth is that the iBEP sensing requires a simple analog-to-digital converter only, which is widely available on microcontrollers. Compared with existing approaches including intra-body communication and physiological sensing, TouchAuth is a low-cost, lightweight, and convenient approach for authorized users to access the smart objects found in indoor environments. Zhenyu Yan 0002, Qun Song 0001, Rui Tan 0001, Yang Li 0147, Adams Wai-Kin Kong |
MobiCom | 4 |
| 2019 | Wearables Clock Synchronization Using Skin Electric PotentialsabstractDesign of clock synchronization for networked nodes faces a fundamental trade-off between synchronization accuracy and universality of heterogeneous platforms, because a high synchronization accuracy generally requires platform-dependent hardware-level network packet timestamping. This paper presents TouchSync, a new indoor clock synchronization approach for wearables that achieves millisecond accuracy while preserving universality in that it uses standard system calls only, such as reading system clock, sampling sensors, and sending/receiving network messages. The design of TouchSync is driven by a key finding from our extensive measurements that the skin electric potentials (SEPs) induced by powerline radiation are salient, periodic, and synchronous on a same wearer and even across different wearers. TouchSync integrates the SEP signal into the universal principle of Network Time Protocol and solves an integer ambiguity problem by fusing the ambiguous results in multiple synchronization rounds to conclude an accurate clock offset between two synchronizing wearables. With our shared code, TouchSync can be readily integrated into any wearable applications. Extensive evaluation based on our Arduino and TinyOS implementations shows that TouchSync's synchronization errors are below 3 and 7 milliseconds on the same wearer and between two wearers 10 kilometers apart, respectively. Zhenyu Yan 0002, Rui Tan 0001, Yang Li 0147, Jun Huang 0001 |
IEEE Trans. Mob. Comput. | 3 |
| 2018 | Simultaneous Localization and Mapping with Power Network Electromagnetic FieldabstractVarious sensing modalities have been exploited for indoor location sensing, each of which has well understood limitations, however. This paper presents a first systematic study on using the electromagnetic field (EMF) induced by a building's electric power network for simultaneous localization and mapping (SLAM). A basis of this work is a measurement study showing that the power network EMF sensed by either a customized sensor or smartphone's microphone as a side-channel sensor is spatially distinct and temporally stable. Based on this, we design a SLAM approach that can reliably detect loop closures based on EMF sensing results. With the EMF feature map constructed by SLAM, we also design an efficient online localization scheme for resource-constrained mobiles. Evaluation in three indoor spaces shows that the power network EMF is a promising modality for location sensing on mobile devices, which is able to run in real time and achieve sub-meter accuracy. Xiaoxuan Lu 0001, Yang Li 0147, Peijun Zhao, Changhao Chen, Linhai Xie, Hongkai Wen 0001, Rui Tan 0001, Agathoniki Trigoni |
MobiCom | 2 |
| 2018 | Natural Timestamps in Powerline Electromagnetic RadiationabstractThe continuous fluctuation of electric network frequency (ENF) presents a fingerprint indicative of time, which we call natural timestamp . This article studies the time accuracy of these natural timestamps obtained from powerline electromagnetic radiation (EMR), which is mainly excited by powerline voltage oscillations at the rate of the ENF. However, since the EMR signal is often weak and noisy, extracting the ENF is challenging, especially on resource-limited sensor platforms. We design an efficient EMR conditioning algorithm and evaluate the time accuracy of EMR natural timestamps on two representative classes of IoT platforms—a high-end single-board computer with a customized EMR antenna and a low-end mote with a normal conductor wire acting as EMR antenna. Extensive measurements at six sites in a city, which are away from each other for up to 24km, show that the high-end and low-end nodes achieve median time errors of about 50ms and 150ms, respectively. To demonstrate the use of the EMR natural timestamps, we discuss three applications: time recovery, runtime clock verification, and secure clock synchronization. Yang Li 0147, Rui Tan 0001, David K. Y. Yau |
ACM Trans. Sens. Networks | 1 |
| 2017 | Natural timestamping using powerline electromagnetic radiationabstractThe continuous fluctuation of electric network frequency (ENF) presents a fingerprint indicative of time, which we call natural timestamp. This paper studies the time accuracy of these natural timestamps obtained from powerline electromagnetic radiation (EMR), which is mainly excited by powerline voltage oscillations at the rate of the ENF. However, since the EMR signal is often weak and noisy, extracting the ENF is challenging, especially on resource-limited sensor platforms. We design an efficient EMR conditioning algorithm and evaluate the time accuracy of EMR natural timestamps on two representative classes of IoT platforms - a high-end single-board computer with a customized EMR antenna and a low-end mote with a normal conductor wire acting as EMR antenna. Extensive measurements at five sites in a city, which are away from each other for up to 24 km, show that the high-end and low-end nodes achieve median time errors of about 50 ms and 150 ms, respectively. To demonstrate the use of the EMR natural timestamps, we discuss two applications, namely time recovery and runtime clock verification. Yang Li 0147, Rui Tan 0001, David K. Y. Yau |
IPSN | 1 |
| 2017 | Natural timestamping using electrical power grid: demo abstractabstractThe continuous fluctuation of electric network frequency (ENF) presents a fingerprint indicative of time, which we call natural timestamp. This live demo demonstrates the accuracy of the natural timestamps obtained by four wired voltage sensors and four wireless electromagnetic radiation (EMR) sensors that are geographically distributed in Singapore. The voltage sensors and the EMR sensors capture the minute fluctuations of the length of each voltage cycle and the average ENF over every 50 voltage cycles, respectively. The evaluation in our prior studies [1, 3] has shown that the natural timestamps recorded by the voltage sensors and the EMR sensors give sub-millisecond and sub-second average time errors, respectively. This demo will also show their time errors. Sreejaya Viswanathan, Yang Li 0147, Rui Tan 0001 |
IPSN | 2 |
| 2017 | Application-Layer Clock Synchronization for Wearables Using Skin Electric Potentials Induced by Powerline RadiationabstractDesign of clock synchronization for networked nodes faces a fundamental trade-off between synchronization accuracy and universality for heterogeneous platforms, because a high synchronization accuracy generally requires platform-dependent hardware-level network packet timestamping. This paper presents TouchSync, a new indoor clock synchronization approach for wearables that achieves millisecond accuracy while preserving universality in that it uses standard system calls only, such as reading system clock, sampling sensors, and sending/receiving network messages. The design of TouchSync is driven by a key finding from our extensive measurements that the skin electric potentials (SEPs) induced by powerline radiation are salient, periodic, and synchronous on a same wearer and even across different wearers. TouchSync integrates the SEP signal into the universal principle of Network Time Protocol and solves an integer ambiguity problem by fusing the ambiguous results in multiple synchronization rounds to conclude an accurate clock offset between two synchronizing wearables. With our shared code, TouchSync can be readily integrated into any wearable applications. Extensive evaluation based on our Arduino and TinyOS implementations shows that TouchSync's synchronization errors are below 3 and 7 milliseconds on the same wearer and between two wearers 10 kilometers apart, respectively. Zhenyu Yan 0002, Yang Li 0147, Rui Tan 0001, Jun Huang 0001 |
SenSys | 2 |