Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Huanran Xie

dblp:383/5395 · DBLP profile ↗
← Back
1ranked-venue papers
0as first author
1since 2021 · last 2024
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Computer networks · 1 · 1 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Human-computer interaction and pervasive computing
1 paper
Wearable and physiological sensing · 91% Health and well-being technologies · 9%

Topics — the 4 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Wearable and physiological sensing › vital sign monitoring
blood pressure monitoring
0.812024
HearBP: Hear Your Blood Pressure via In-ear Acoustic Sensing Based on Heart Sounds · INFOCOM 2024
Wearable and physiological sensing › biosignal sensing
heart sound sensing
0.812024
HearBP: Hear Your Blood Pressure via In-ear Acoustic Sensing Based on Heart Sounds · INFOCOM 2024
Wearable and physiological sensing › earable sensing
in-ear acoustic sensing
0.812024
HearBP: Hear Your Blood Pressure via In-ear Acoustic Sensing Based on Heart Sounds · INFOCOM 2024
Health and well-being technologies
continuous blood pressure monitoring
0.212024
HearBP: Hear Your Blood Pressure via In-ear Acoustic Sensing Based on Heart Sounds · INFOCOM 2024

Methods — techniques the papers use, named apart from their topics

u-net autoencoder-decoder · 0.8shannon energy · 0.8dendritic neural regression · 0.8
YearPublicationVenuePosition
2024 HearBP: Hear Your Blood Pressure via In-ear Acoustic Sensing Based on Heart Sounds
abstract
Continuous blood pressure (BP) monitoring using wearable devices has received increasing attention due to its importance in diagnosing diseases. However, existing methods mainly measure BP intermittently, involve some form of user effort, and suffer from insufficient accuracy due to sensor properties. In order to overcome these limitations, we study the BP measurement technology based on heart sounds, and find that the time interval between the first and second heart sounds (TIFS) of bone-conducted heart sounds collected in the binaural canal is closely related to BP. Motivated by this, we propose HearBP, a novel BP monitoring system that utilizes inear microphones to collect bone-conducted heart sounds in the binaural canal. We first design a noise removing method based on U-net autoencoder-decoder to separate clean heart sounds from background noises. Then, we design a feature extraction method based on shannon energy and energy-entropy ratio to further mine the time domain and frequency domain features of heart sounds. In addition, combined with the principal component analysis algorithm, we achieve feature dimension reduction to extract the main features related to BP. Finally, we propose a network model based on dendritic neural regression to construct a mapping between the extracted features and BP. Extensive experiments with 41 participants show the average estimation error of 0.97mmHg and 1.61mmHg and the standard deviation error of 3.13mmHg and 3.56mmHg for diastolic pressure and systolic pressure, respectively. These errors are within the acceptable range specified by the FDA’s AAMI protocol.
Zhiyuan Zhao 0009, Fan Li 0001, Yadong Xie, Huanran Xie, Kerui Zhang, Li Zhang 0028, Yu Wang 0003
INFOCOM4