Demo Data from VLDB 2026 / reviewers in the wild / expert
Hui Ji 0003
dblp:52/6573-3
· DBLP profile ↗
2ranked-venue papers
2as first author
2since 2021 · last 2024
0009-0006-8756-8687ORCID · verified
Domains — the database's venue-derived domains; a paper can count in several
Computer networks · 2 · 2 first-author · 2 since 2021
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Human-computer interaction and pervasive computing
2 papers |
Health and well-being technologies · 67% Wearable and physiological sensing · 33% |
Topics — the 3 heaviest of 3, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Health and well-being technologies › health monitoring
cardiac monitoring |
1.5 | 2 | 2024 | Demo Abstract: Advancing PPG-Based Continuous Blood Pressure Monitoring from a Generative Perspective · SenSys 2024 Advancing PPG-Based Continuous Blood Pressure Monitoring from a Generative Perspective · SenSys 2024 |
Health and well-being technologies › continuous blood pressure monitoring
cuffless blood pressure monitoring |
1.5 | 2 | 2024 | Demo Abstract: Advancing PPG-Based Continuous Blood Pressure Monitoring from a Generative Perspective · SenSys 2024 Advancing PPG-Based Continuous Blood Pressure Monitoring from a Generative Perspective · SenSys 2024 |
Wearable and physiological sensing
physiological signal analysis |
1.5 | 2 | 2024 | Demo Abstract: Advancing PPG-Based Continuous Blood Pressure Monitoring from a Generative Perspective · SenSys 2024 Advancing PPG-Based Continuous Blood Pressure Monitoring from a Generative Perspective · SenSys 2024 |
Methods — techniques the papers use, named apart from their topics
generative modeling · 1.5diffusion model · 1.5
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2024 | Advancing PPG-Based Continuous Blood Pressure Monitoring from a Generative PerspectiveabstractCuffless blood pressure (BP) monitoring is a critical task in the cardiovascular diseases (CVDs) domain, commonly based on Photoplethysmography (PPG) and Electrocardiogram (ECG) signals, providing foresight into cardiac health. While ECG often delivers better BP monitoring performance, the acquisition via straps and patches leads to a poor user experience. On the contrary, PPG enables continuous and convenient monitoring, but offers less informative references. A potential approach is to convert PPG signals into ECG signals, ensuring both high convenience and optimal accuracy. Converting PPG into ECG, however, involves a substantial reduction in inherent entropy, necessitating a thorough understanding of the process and specific techniques to guide the ECG generation. In this paper, we present a blood pressure monitoring framework that achieves ECG-level performance using solely the PPG signal. A diffusion model is introduced to conduct a selective ECG-targeted generative process with the condition of PPG. Based on our observation from the experimental investigation, a set of techniques is developed to significantly enhance the model's ability in generating high-quality ECG signals. Specifically, in the forward process, we employ an adaptive search module to adapt the QRS segment within the ECG waveform. In the reverse process, we propose the scale alignment and frequency alignment modules to better guide the generative process. Extensive experiments conducted on two public datasets and one self-collected dataset demonstrate the superior performance of our proposed framework, offering a groundbreaking perspective for PPG-based continuous blood pressure monitoring. Hui Ji 0003 |
SenSys | 1 |
| 2024 | Demo Abstract: Advancing PPG-Based Continuous Blood Pressure Monitoring from a Generative PerspectiveabstractCuffless blood pressure (BP) monitoring is a critical task in the cardiovascular diseases (CVDs) domain, commonly based on Photoplethysmography (PPG) and Electrocardiogram (ECG) signals. While ECG often delivers better BP monitoring performance, the acquisition via straps and patches leads to a poor user experience. On the contrary, PPG enables continuous and convenient monitoring, but offers less informative references. A potential approach is to convert PPG signals into ECG signals, ensuring both high convenience and optimal accuracy. Converting PPG into ECG, however, involves a substantial reduction in inherent entropy, necessitating a thorough understanding of the process and specific techniques to guide the ECG generation. In this demo, we present a blood pressure monitoring framework that achieves ECG-level performance using solely the PPG signal. A diffusion model is introduced to conduct a selective ECG-targeted generative process with the condition of PPG. Based on our observation from the experimental investigation, a set of techniques is developed to significantly enhance the model's ability in generating high-quality ECG signals. Specifically, in the forward process, we employ an adaptive search module to adapt the QRS segment within the ECG waveform. In the reverse process, we propose the scale alignment and frequency alignment modules to better guide the generative process. This framework bridges the gap between PPG convenience and ECG accuracy for improved BP monitoring. Hui Ji 0003 |
SenSys | 1 |