Demo Data from VLDB 2026 / reviewers in the wild / expert
Junichi Tokuda
dblp:53/2573
· DBLP profile ↗
13ranked-venue papers
4as first author
1since 2021 · last 2024
0000-0003-2358-7484ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 6 · 1 since 2021Systems, architecture and hardware · 6 · 1 since 2021Applied, interdisciplinary, general and emerging computing · 6 · 4 first-authorGraphics, computer vision, multimedia, augmented reality and games · 5 · 4 first-authorHuman-computer interaction and ubiquitous computing · 1
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Interdisciplinary, comprehensive, and emerging computing
4 papers |
Medical and health informatics · 89% Computational science and engineering · 11% | |
| Artificial intelligence
4 papers |
Robot manipulation · 78% Robot navigation and mapping · 17% Motion planning and robot control · 5% | |
| Human-computer interaction and pervasive computing
2 papers |
Interaction techniques and input · 73% User interface design and tools · 22% Health and well-being technologies · 6% |
Topics — the 11 heaviest of 15, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Medical and health informatics
computer-assisted intervention |
0.8 | 1 | 2024 | Bevel-Tip Needle Deflection Modeling, Simulation, and Validation in Multi-Layer Tissues · ICRA 2024 |
Medical and health informatics › computer-assisted surgery
needle insertion |
0.8 | 1 | 2024 | Bevel-Tip Needle Deflection Modeling, Simulation, and Validation in Multi-Layer Tissues · ICRA 2024 |
Computational science and engineering
finite element analysis |
0.2 | 1 | 2024 | Bevel-Tip Needle Deflection Modeling, Simulation, and Validation in Multi-Layer Tissues · ICRA 2024 |
Robotics › Robot manipulation
medical robotics |
0.2 | 2 | 2008 | Integrated system for robot-assisted in prostate biopsy in closed MRI scanner · ICRA 2008 Pneumatically operated MRI-compatible needle placement robot for prostate interventions · ICRA 2008 |
Medical and health informatics › image-guided intervention
MRI-guided intervention |
0.2 | 1 | 2013 | Towards clinically optimized MRI-guided surgical manipulator for minimally invasive prostate percutaneous interventions: constructive design · ICRA 2013 |
Medical and health informatics
image-guided intervention |
0.1 | 2 | 2008 | Pneumatically operated MRI-compatible needle placement robot for prostate interventions · ICRA 2008 Needle Guiding Robot for MR-guided Microwave Thermotherapy of Liver Tumor using Motorized Remote-Center-of-Motion Constraint · ICRA 2005 |
Robotics › Robot manipulation › medical robotics
robotic biopsy |
0.1 | 1 | 2008 | Integrated system for robot-assisted in prostate biopsy in closed MRI scanner · ICRA 2008 |
Robotics › Robot manipulation › medical robotics
needle insertion |
0.1 | 1 | 2005 | Needle Guiding Robot for MR-guided Microwave Thermotherapy of Liver Tumor using Motorized Remote-Center-of-Motion Constraint · ICRA 2005 |
Robotics › Robot manipulation › medical robotics
surgical manipulator |
0.0 | 1 | 2013 | Towards clinically optimized MRI-guided surgical manipulator for minimally invasive prostate percutaneous interventions: constructive design · ICRA 2013 |
Robotics › Robot manipulation › actuator design
pneumatic actuation |
0.0 | 1 | 2008 | Pneumatically operated MRI-compatible needle placement robot for prostate interventions · ICRA 2008 |
Robotics › Motion planning and robot control
robot control |
0.0 | 1 | 2008 | Pneumatically operated MRI-compatible needle placement robot for prostate interventions · ICRA 2008 |
Methods — techniques the papers use, named apart from their topics
mechanics-based modeling · 0.8finite element method · 0.8kinematic optimization · 0.3finite element analysis · 0.3empirical evaluation · 0.3electroluminescence screen printing · 0.3transperineal needle insertion · 0.2pneumatic actuation · 0.2magnetic resonance imaging · 0.2intra-operative MRI · 0.2optical fiber sensing · 0.1remote-center-of-motion constraint · 0.1remote center of motion constraint · 0.1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2024 | Bevel-Tip Needle Deflection Modeling, Simulation, and Validation in Multi-Layer TissuesabstractPercutaneous needle insertions are commonly performed for diagnostic and therapeutic purposes as an effective alternative to more invasive surgical procedures. However, the outcome of needle-based approaches relies heavily on the accuracy of needle placement, which remains a challenge even with robot assistance and medical imaging guidance due to needle deflection caused by contact with soft tissues. In this paper, we present a novel mechanics-based 2D bevel-tip needle model that can account for the effect of nonlinear strain-dependent behavior of biological soft tissues under compression. Real-time finite element simulation allows multiple control inputs along the length of the needle with full three-degree-of-freedom (DOF) planar needle motions. Cross-validation studies using custom-designed multi-layer tissue phantoms as well as heterogeneous chicken breast tissues result in less than 1mm in-plane errors for insertions reaching depths of up to 61 mm, demonstrating the validity and generalizability of the proposed method. Yanzhou Wang, Lidia Al-Zogbi, Guanyun Liu, Junichi Tokuda, Axel Krieger, Iulian Iordachita |
ICRA | 5 |
| 2018 | Insert Needle Here! A Custom Display for Optimized Biopsy Needle PlacementabstractNeedle-guiding templates are used for a variety of minimally invasive medical interventions. While physically supporting needle placement with a grid of holes, they lack integrated information where needles need to be inserted. Physicians must manually determine the correct holes based on the output of planning software - a workflow that is error-prone and lengthy. We address these issues by embedding a display into the template using electroluminescence (EL) screen printing. The EL display is connected to planning software and illuminates the correct hole. In an empirical evaluation with physicians and researchers from the medical domain, we compare the illuminated against the conventional template as used in magnetic resonance imaging (MRI) guided prostate biopsies. Our results show that the EL display significantly improves task completion time by 51%, task load by 47% and usability by 30%. Anke V. Reinschlüssel, Marc Herrlich, Tanja Döring, Mark G. Vangel, Clare M. Tempany, Rainer Malaka, Junichi Tokuda |
CHI | 7 |
| 2016 | Increasing the impact of medical image computing using community-based open-access hackathons: The NA-MIC and 3D Slicer experience
Tina Kapur, Steven D. Pieper, Andriy Fedorov, Jean-Christophe Fillion-Robin, Michael Halle, Lauren O'Donnell, Andras Lasso, Tamas Ungi, Csaba Pinter, Julien Finet, Sonia Pujol, Jayender Jagadeesan, Junichi Tokuda, Isaiah Norton, Raúl San José Estépar, David T. Gering, Hugo J. W. L. Aerts, Marianna Jakab, Nobuhiko Hata, Luiz Ibáñez, Daniel J. Blezek, Jim Miller, Stephen R. Aylward, W. Eric L. Grimson, Gabor Fichtinger, William M. Wells III, William E. Lorensen, William J. Schroeder, Ron Kikinis |
Medical Image Anal. | 13 |
| 2013 | Towards clinically optimized MRI-guided surgical manipulator for minimally invasive prostate percutaneous interventions: constructive designabstractThis paper undertakes the modular design and development of a minimally invasive surgical manipulator for MRI-guided transperineal prostate interventions. Severe constraints for the MRI-compatibility to hold the minimum artifact on the image quality and dimensions restraint of the bore scanner shadow the design procedure. Regarding the constructive design, the manipulator kinematics has been optimized and the effective analytical needle workspace is developed and followed by proposing the workflow for the manual needle insertion. A study of the finite element analysis is established and utilized to improve the mechanism weaknesses under some inevitable external forces to ensure the minimum structure deformation. The procedure for attaching a sterile plastic drape on the robot manipulator is discussed. The introduced robotic manipulator herein is aimed for the clinically prostate biopsy and brachytherapy applications. Sohrab Eslami, Gregory S. Fischer, Sang-Eun Song, Junichi Tokuda, Nobuhiko Hata, Clare M. Tempany, Iulian Iordachita |
ICRA | 4 |
| 2013 | Design evaluation of a double ring RCM mechanism for robotic needle guidance in MRI-guided liver interventionsabstractMRI-guided percutaneous liver interventions have been investigated by researchers as an alternative to CT-guided procedures as it is non-invasive and provides greater soft tissue details. In practice, however, repeated needle insertion is still required to reach desired positions on trial-and-error basis. To minimize the needle attempt and procedural time, we designed a robotic needle guidance device that provides needle insertion angle guidance at skin entry using two rotational joints structured for remote-center-of-motion manipulation. To evaluate the mechanism and clinical feasibility, we fabricated a proof-of-concept prototype that can be manually operated. As preliminary design evaluation, we conducted a retrospective clinical study of 13 MRI-guided abdominal biopsies to determine if the proposed mechanism and device can provide necessary needle insertion angles in MRI-guided liver biopsy procedures. The number of needle insertion attempts per biopsy was also measured. To confirm the kinematic design of the double ring remote-center-of-motion mechanism and to identify any procedural difficulties, we conducted a phantom targeting experiment. The retrospective clinical study showed that the 80 degree insertion angle coverage of the device is sufficient for clinical cases, and an average of five needle insertion attempts per biopsy in conventional MRI-guided biopsy can be reduced by the proposed device. A phantom targeting experiment confirmed that the unique kinematic design was successfully implementation in the targeting. Sang-Eun Song, Junichi Tokuda, Kemal Tuncali, Atsushi Yamada, Meysam Torabi, Nobuhiko Hata |
IROS | 2 |
| 2013 | Configurable Automatic Detection and Registration of Fiducial Frames for Device-to-Image Registration in MRI-Guided Prostate Interventions
Junichi Tokuda, Sang-Eun Song, Kemal Tuncali, Clare M. Tempany, Nobuhiko Hata |
MICCAI (3) | 1 |
| 2008 | Pneumatically operated MRI-compatible needle placement robot for prostate interventionsabstractMagnetic Resonance Imaging (MRI) has potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. The strong magnetic field prevents the use of conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intra-prostatic needle placement inside closed high-field MRI scanners. The robot performs needle insertion under real-time 3T MR image guidance; workspace requirements, MR compatibility, and workflow have been evaluated on phantoms. The paper explains the robot mechanism and controller design and presents results of preliminary evaluation of the system. Gregory S. Fischer, Iulian Iordachita, Csaba Csoma, Junichi Tokuda, Philip Walter Mewes, Clare M. Tempany, Nobuhiko Hata, Gabor Fichtinger |
ICRA | 4 |
| 2008 | Integrated system for robot-assisted in prostate biopsy in closed MRI scannerabstractProstate cancer biopsy is a routine medical procedure, yet conventional techniques suffer from low sensitivity attributed to suboptimal image guidance and needle placement. Targeting small lesions and foci (5 mm in diameter) is particularly prone to errors. We developed an integrated system to perform robot-assisted transperineal needle insertions into the prostate, under Magnetic Resonance Imaging (MRI) guidance. The system provides arbitrary needle trajectories and allows for simultaneous surveillance and correction of the needle path, based on intra-operative MRI. System functionality and data transfer and processing tests were conducted. Five lesions embedded in the gel phantom were targeted successfully, while communication delays (due to higher image frame rates) had no adverse affect on robot-software communication. The system was sufficiently resistant to high network loads and performed with an acceptable transfer rate. Philip Walter Mewes, Junichi Tokuda, Simon P. DiMaio, Gregory S. Fischer, Csaba Csoma, David G. Gobbi, Clare M. Tempany, Gabor Fichtinger, Nobuhiko Hata |
ICRA | 2 |
| 2008 | Software Strategy for Robotic Transperineal Prostate Therapy in Closed-Bore MRI
Junichi Tokuda, Gregory S. Fischer, Csaba Csoma, Simon P. DiMaio, David G. Gobbi, Gabor Fichtinger, Clare M. Tempany, Nobuhiko Hata |
MICCAI (2) | 1 |
| 2006 | New 4-D Imaging for Real-Time Intraoperative MRI: Adaptive 4-D Scan
Junichi Tokuda, Shigehiro Morikawa, Hasnine A. Haque, Tetsuji Tsukamoto, Kiyoshi Matsumiya, Hongen Liao, Ken Masamune, Takeyoshi Dohi |
MICCAI (1) | 1 |
| 2005 | Needle Guiding Robot for MR-guided Microwave Thermotherapy of Liver Tumor using Motorized Remote-Center-of-Motion ConstraintabstractSearching for optimal needle insertion path by intraoperative magnetic resonance imaging (MRI) is complex and time-consuming task in MR-guided microwave thermotherapy of liver tumor. This paper reports the semi-active needle-guiding robot for MR-guided therapy by which a surgeon can freely selects needle insertion path while maintaining the remote center of motion at the pre-defined tumor site. The robot consists of three-degree-of-freedom active XYZ base stage with ultrasonic motors and passive needle holder with unconstrained two-degree-of-freedom rotation measured by optical fiber sensor with aluminum die cast. Once the target point on the tumor is defined in volumetric MR images, the base stage keeps the remote-center-of-motion at the target point, while physician can interactively selects the orientation of the needle path with continuous single slice MR imaging. Experiments to test the accuracy of remote-center-of-motion indicated that the robot can keep the needle tip with an average error of 0.7 ∼ 0.3 mm in the compatibility test showed the robot can be safely used in MR axial plane, and 1.0-0.4 mm in the sagittal plane. Unlike related studies published elsewhere where the MR compatible robot autonomously brings the tools to predefined location, the proposed approach is fit to use in microwave thermotherapy of liver cancer. Nobuhiko Hata, Ryuji Hashimoto, Junichi Tokuda, Shigeo Morikawa |
ICRA | 3 |
| 2003 | Integration of Projection Profile Matching into Clinical MR Scanner System for Real-Time Organ Tracking and Image Registration
Junichi Tokuda, Masaya Hirano, Tetsuji Tsukamoto, Takeyoshi Dohi, Nobuhiko Hata |
MICCAI (2) | 1 |
| 2002 | Projection Profile Matching for Intraoperative MRI Registration Embedded in MR Imaging Sequence
Nobuhiko Hata, Junichi Tokuda, Shigeo Morikawa, Takeyoshi Dohi |
MICCAI (2) | 2 |