Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Kostas Vlachos

dblp:63/1734 · DBLP profile ↗
← Back
8ranked-venue papers
3as first author
0since 2021 · last 2015
0000-0002-9716-7661ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 6 · 2 first-authorSystems, architecture and hardware · 6 · 2 first-authorApplied, interdisciplinary, general and emerging computing · 2 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
1 paper
Motion planning and robot control · 91% Legged, aerial and field robots · 9%
Human-computer interaction and pervasive computing
4 papers
Haptics and multimodal interaction · 75% Health and well-being technologies · 20% Learning and educational technologies · 4%
Theoretical computer science
1 paper
Mathematical optimization · 50% Algorithmic game theory and mechanism design · 50%
Computer architecture, parallel and distributed computing, and storage systems
1 paper
Embedded and real-time systems · 77% Hardware accelerators and domain-specific architectures · 23%

Topics — the 13 heaviest of 14, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Haptics and multimodal interaction › haptic interface
haptic device design
0.132004
Mass/inertia and Joint Friction Minimization for a Low-force Five-dof Haptic Device · ICRA 2004
Design and implementation of a haptic device for training in urological operations · IEEE Trans. Robotics Autom. 2003
Design of a 5-DOF Haptic Simulator for Urological Operations · ICRA 2002
Robotics › Motion planning and robot control › robot control
control allocation
0.112010
Control design and allocation of an over-actuated triangular floating platform · ICRA 2010
Robotics › Motion planning and robot control › robot control › motion control
dynamic positioning
0.112010
Control design and allocation of an over-actuated triangular floating platform · ICRA 2010
Robotics › Motion planning and robot control
robot control
0.112010
Control design and allocation of an over-actuated triangular floating platform · ICRA 2010
Haptics and multimodal interaction › haptic interface
force display
0.122003
Design and implementation of a haptic device for training in urological operations · IEEE Trans. Robotics Autom. 2003
Design of a 5-DOF Haptic Simulator for Urological Operations · ICRA 2002
Embedded and real-time systems › cyber-physical systems › robot systems
microrobotics
0.112007
On the Force Capabilities of Centripetal Force-actuated Microrobotic Platforms · ICRA 2007
Health and well-being technologies › medical simulation
surgical simulation
0.122004
A Real-time Graphic Environment for a Urological Operation Training Simulator · ICRA 2004
Design of a 5-DOF Haptic Simulator for Urological Operations · ICRA 2002
Algorithmic game theory and mechanism design › mechanism design › algorithmic mechanism design
mechanism design optimization
0.012004
Mass/inertia and Joint Friction Minimization for a Low-force Five-dof Haptic Device · ICRA 2004
Mathematical optimization
multi-objective optimization
0.012004
Mass/inertia and Joint Friction Minimization for a Low-force Five-dof Haptic Device · ICRA 2004
Robotics › Legged, aerial and field robots
underwater robotics
0.012010
Control design and allocation of an over-actuated triangular floating platform · ICRA 2010
Medical and health informatics › medical simulation
surgical simulation
0.012004
Mass/inertia and Joint Friction Minimization for a Low-force Five-dof Haptic Device · ICRA 2004
Haptics and multimodal interaction › haptic feedback
force feedback
0.012004
A Real-time Graphic Environment for a Urological Operation Training Simulator · ICRA 2004
Learning and educational technologies › medical training
surgical training
0.012003
Design and implementation of a haptic device for training in urological operations · IEEE Trans. Robotics Autom. 2003

Methods — techniques the papers use, named apart from their topics

multi-objective optimization · 0.1mass/inertia minimization · 0.1over-actuated control · 0.1manipulability optimization · 0.1force ripple attenuation · 0.1dynamic modeling · 0.1particle-based force model · 0.0bezier interpolation · 0.0force feedback control · 0.0capstan drive transmission · 0.0static balancing · 0.0capstan drive · 0.0
YearPublicationVenuePosition
2015 Backstepping control with energy reduction for an over-actuated marine platform
abstract
We present the design of a backstepping controller for a triangular over-actuated marine platform, controlled by three rotating jets. Our goal is the stabilization of the position and the orientation of the platform, under realistic environmental disturbances, such as wind forces, wave forces and hydrodynamic forces. Actuator thrust and angle dynamics, as well as settling delays, in the rotation of the jets and in the response of the desired thrust, are included in the algorithm, despite the presence of an allocation scheme. Thrust and angle velocity, limitations are also taken into account. A Thrust Upper Limit (TUL) manipulation heuristic is introduced in order to reduce the thrust requirements and the energy consumed. The performance of the developed backstepping controller is compared to the case with and without the TUL. Simulation results show that the use of the heuristic reduces energy consumption.
Aristomenis Tsopelakos, Kostas Vlachos, Evangelos Papadopoulos
ICRA2
2013 Analysis and Motion Control of a Centrifugal-Force Microrobotic Platform
abstract
This paper presents the analysis, design, and closed-loop motion control of a mobile microrobotic platform capable of micrometer positioning on a plane. The mobile microrobot, including chassis, actuators, drives, microprocessor, and electronics, is of low cost (less than $20), can be fabricated rapidly and is made of commercially available components. Its motion is induced by centrifugal forces generated by two vibration motors installed inside the platform body. The asynchronous operation of the vibration motors is shown by simulation to result in planar motions of two degrees-of-freedom locally, with micrometer resolution. A motion controller has been designed to generate controlled motions using sets of motor angular velocities. A prototype has been developed and used to validate the motion principle and the controller efficacy. Open loop experiments show that the platform motion resolution is approximately 20 μm, while its speed is greater than 2 mm/s. Closed-loop experiments demonstrate a 5 μm resolution, i.e., a fourfold improvement compared to the open loop experiments. The low cost, the rapid fabrication, and the micrometer motion resolution suggest that this microrobotic platform is a promising solution for low-cost microfactories, where a group of such robots performs high throughput, advanced microassembly of microsystems.
Panagiotis Vartholomeos, Kostas Vlachos, Evangelos Papadopoulos
IEEE Trans Autom. Sci. Eng.2
2010 Control design and allocation of an over-actuated triangular floating platform
abstract
This paper presents the design and practical implementation of an autonomous dynamic positioning scheme, i.e., the stabilization of linear and angular velocities as well as the position and orientation, of a novel triangular floating sea platform. The required closed-loop forces and moments must be provided by three rotating pump jets, located at the bottom of three partly submerged cylinders located at the three corners of the platform. With this control configuration the platform is over-actuated, i.e., it has more control inputs than degrees of freedom (DOF). Design rules that maximize the manipulability of the platform, and a control allocation scheme that allows goal realization without violating thruster capabilities are developed. Simulations results, including environmental disturbances, are presented that demonstrate the performance of the controller, and the allocation scheme employed.
Kostas Vlachos, Evangelos Papadopoulos
ICRA1
2007 On the Force Capabilities of Centripetal Force-actuated Microrobotic Platforms
abstract
In this paper a study is conducted on the force capabilities of centripetal force actuated microrobotic platforms. The aim is to exploit the centripetal forces generated by platform mounted vibrating micro-motors for micromanipulation purposes. First, an overview of the platform dynamics and motion capabilities is presented. The type of forces generated by the actuation mechanism as well as due to the impulsive interaction with the working environment are studied. Then design steps are proposed for (i) the reduction or elimination of undesired impulsive forces, (ii) the attenuation of the force ripple transmitted to the manipulated object. The outcome is a smooth, controllable force transmitted to the manipulated object. A cantilever is mounted on the platform and preliminary experiments are conducted.
Panagiotis Vartholomeos, Kostas Vlachos, Evangelos Papadopoulos
ICRA2
2004 A Real-time Graphic Environment for a Urological Operation Training Simulator
abstract
An OpenGL/C++ real-time graphic environment, part of a training simulator for urological operations, is presented. The graphic environment simulates endoscope insertion in a small diameter deformable tube and is used with a low-force 5-dof force-feedback haptic mechanism. Piecewise Bezier interpolations are used for smooth urethra deformations. A novel particle-based model computes the forces and torques fed to the haptics. Realistic textures from medical databases are employed and a 25 fps refresh rate is achieved using the Rendering Thread method. The overall simulator software is made of three processes running on two distinct platforms, communicating via Ethernet and TCP/IP.
Evangelos Papadopoulos, Alkiviadis Tsamis, Kostas Vlachos
ICRA3
2004 Mass/inertia and Joint Friction Minimization for a Low-force Five-dof Haptic Device
abstract
This work presents a design methodology, which aims at the minimization of the mass, inertia and joint friction for a low - force five - dof haptic device. The haptic device is optimized along a typical path with proper tolerances, rather than at some workspace operating point. The device, part of a training medical simulator for urological operations, consists of a two dof, 5-bar linkage and a three dof spherical joint. The requirement for reliable reproduction of low torques and forces lead to the need for minimization of device induced parasitic forces and torques. The multiobjective optimization employed is based on two objective functions that include mass/ inertia properties and joint friction. The kinematical and operational constraints are taken into account. The resulting optimized mechanism is substantially improved with respect to an existing device.
Kostas Vlachos, Evangelos Papadopoulos, Dionyssios Mitropoulos
ICRA1
2003 Design and implementation of a haptic device for training in urological operations
abstract
Virtual reality is becoming very important for training medical surgeons in various operations. Interfacing users with a virtual training environment requires the existence of a properly designed haptic device. This paper presents the design and implementation of a new force feedback haptic mechanism with five active degrees of freedom (DOFs), which is used as part of a training simulator for urological operations. The mechanism consists of a 2-DOF, 5-bar linkage, and a 3-DOF spherical joint, designed to present low friction, inertia and mass, and to be statically balanced. The device is suitable for the accurate application of small forces and moments. All five actuators of the haptic device are base-mounted dc motors and use a force transmission system based on capstan drives, pulleys, and tendons. The paper describes the overall design and sizing considerations, the resulting kinematics and dynamics, the force feedback control algorithm, and the hardware employed. Experimental results are provided.
Kostas Vlachos, Evangelos Papadopoulos, Dionissios N. Mitropoulos
IEEE Trans. Robotics Autom.1
2002 Design of a 5-DOF Haptic Simulator for Urological Operations
abstract
A haptic feedback mechanism with five active degrees of freedom (dof), part of a training simulator for urological operations, is presented. The mechanism consists of a 2-dof 5-bar linkage, and a 3-dof spherical joint. To reproduce very small forces and moments, the mechanism has low friction, inertia and mass, is statically balanced, and has a simple mass matrix. Roll-pitch-yaw motions of the tool result in motions of the corresponding actuator. Force feedback transmission is achieved via capstan drives and idler pulleys. The computation of the currents and the structure of the control loop are described.
Evangelos Papadopoulos, Kostas Vlachos, Dionyssios Mitropoulos
ICRA2