Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Philippe Cinquin

dblp:63/3665 · DBLP profile ↗
← Back
23ranked-venue papers
0as first author
0since 2021 · last 2016
0000-0002-2700-1447ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 17Graphics, computer vision, multimedia, augmented reality and games · 13Artificial intelligence and machine learning · 6Systems, architecture and hardware · 5

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
6 papers
Robot manipulation · 95% Motion planning and robot control · 3% Robot navigation and mapping · 1%
Interdisciplinary, comprehensive, and emerging computing
4 papers
Medical and health informatics · 100%
Human-computer interaction and pervasive computing
1 paper
Human-robot interaction · 77% Health and well-being technologies · 23%

Topics — the 18 heaviest of 20, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation
medical robotics
0.322016
Design and Validation of a CT- and MRI-Guided Robot for Percutaneous Needle Procedures · IEEE Trans. Robotics 2016
A new robot architecture for tele-echography · IEEE Trans. Robotics Autom. 2003
Robotics › Robot manipulation › robot design
robot design and kinematics
0.212016
Design and Validation of a CT- and MRI-Guided Robot for Percutaneous Needle Procedures · IEEE Trans. Robotics 2016
Medical and health informatics
computer-assisted intervention
0.112006
Medical Image Computing and Computer-Aided Medical Interventions Applied to Soft Tissues: Work in Progress in Urology · Proc. IEEE 2006
Medical and health informatics
medical robotics
0.112006
Medical Image Computing and Computer-Aided Medical Interventions Applied to Soft Tissues: Work in Progress in Urology · Proc. IEEE 2006
Medical and health informatics
surgical navigation
0.112006
Medical Image Computing and Computer-Aided Medical Interventions Applied to Soft Tissues: Work in Progress in Urology · Proc. IEEE 2006
Robotics › Robot manipulation
robot design
0.112005
Safety and Accuracy Considerations in Developing a Small Sterilizable Robot for Orthopaedic Surgery · ICRA 2005
Medical and health informatics › surgical robotics
orthopedic surgical robot
0.112005
Safety and Accuracy Considerations in Developing a Small Sterilizable Robot for Orthopaedic Surgery · ICRA 2005
Medical and health informatics
surgical robotics
0.112005
Safety and Accuracy Considerations in Developing a Small Sterilizable Robot for Orthopaedic Surgery · ICRA 2005
Robotics › Robot manipulation
cable-driven robot
0.012003
A new robot architecture for tele-echography · IEEE Trans. Robotics Autom. 2003
Robotics › Robot manipulation › telemanipulation
master-slave teleoperation
0.012003
A new robot architecture for tele-echography · IEEE Trans. Robotics Autom. 2003
Robotics › Robot manipulation › medical robotics › medical robot control
surgical robot control
0.012002
A Compact, Compliant Laparoscopic Endoscope Manipulator · ICRA 2002
Human-robot interaction › healthcare robotics
medical robotics
0.012002
A Compact, Compliant Laparoscopic Endoscope Manipulator · ICRA 2002
Robotics › Motion planning and robot control
robot control
0.022005
Safety and Accuracy Considerations in Developing a Small Sterilizable Robot for Orthopaedic Surgery · ICRA 2005
Image guided operating robot: a clinical application in stereotactic neurosurgery · ICRA 1992
Health and well-being technologies › medical technology
surgical assistance
0.012002
A Compact, Compliant Laparoscopic Endoscope Manipulator · ICRA 2002
Robotics › Robot navigation and mapping
sensor calibration
0.011992
Accurate calibration of cameras and range imaging sensor: the NPBS method · ICRA 1992
Medical and health informatics
computer-assisted surgery
0.011992
Image guided operating robot: a clinical application in stereotactic neurosurgery · ICRA 1992
Computer vision › 3D vision › range sensing › depth sensing
range image
0.011992
Accurate calibration of cameras and range imaging sensor: the NPBS method · ICRA 1992
Medical and health informatics
medical imaging
0.011992
Image guided operating robot: a clinical application in stereotactic neurosurgery · ICRA 1992

Methods — techniques the papers use, named apart from their topics

registration · 0.2MRI imaging · 0.2CT imaging · 0.2mechanical braking system · 0.1gear transmission · 0.1master-slave control · 0.1cable-driven actuation · 0.1open-loop control · 0.1feedback control · 0.1surgical navigation · 0.1robotization · 0.1image fusion · 0.1six-axis robot · 0.0linear guide · 0.0b-spline approximation · 0.0
YearPublicationVenuePosition
2016 Design and Validation of a CT- and MRI-Guided Robot for Percutaneous Needle Procedures
abstract
This paper describes the design and evaluation of the second generation of a robotic system called the light puncture robot for thoracic and abdominopelvic interventional radiology procedures under CT and MRI guidance. It is mounted on the patient's body and positions and inserts the needle according to the trajectory and target chosen by the radiologist in the image. The mechanical design is described in detail along with its forward and inverse kinematics. The robot can be segmented and registered fully automatically in both imaging modalities. Phantom experiments in the CT scanner and preliminary feasibility experiments in the MRI are described, showing a targeting accuracy of 3.3 ± 1.7 mm in gelatin for depths ranging from 30 to 90 mm and needle orientations of -13° to +15° about normal from the patient's skin. A detailed error analysis is discussed along with potential improvements in the system. The potential clinical advantages of the system include higher targeting accuracy for complex dual obliquity trajectories, the need for fewer images, and improved accessibility to MRI-guided interventions.
Nikolai Hungr, Ivan Bricault, Philippe Cinquin, Céline Fouard
IEEE Trans. Robotics3
2011 Interventional Radiology Robot for CT and MRI Guided Percutaneous Interventions
Nikolai Hungr, Céline Fouard, Adeline Robert, Ivan Bricault, Philippe Cinquin
MICCAI (1)5
2011 3D Tracking of Laparoscopic Instruments Using Statistical and Geometric Modeling
Rémi Wolf, Josselin Duchateau, Philippe Cinquin, Sandrine Voros
MICCAI (1)3
2006 Automatic Localization of Laparoscopic Instruments for the Visual Servoing of an Endoscopic Camera Holder
Sandrine Voros, Jean-Alexandre Long, Philippe Cinquin
MICCAI (1)3
2006 Medical Image Computing and Computer-Aided Medical Interventions Applied to Soft Tissues: Work in Progress in Urology
abstract
Until recently, computer-aided medical interventions (CAMI) and medical robotics have focused on rigid and nondeformable anatomical structures. Nowadays, special attention is paid to soft tissues, raising complex issues due to their mobility and deformation. Mini-invasive digestive surgery was probably one of the first fields where soft tissues were handled through the development of simulators, tracking of anatomical structures and specific assistance robots. However, other clinical domains, for instance urology, are concerned. Indeed, laparoscopic surgery, new tumour destruction techniques (e.g., HIFU, radiofrequency, or cryoablation), increasingly early detection of cancer, and use of interventional and diagnostic imaging modalities, recently opened new challenges to the urologist and scientists involved in CAMI. This resulted in the last five years in a very significant increase of research and developments of computer-aided urology systems. In this paper, we propose a description of the main problems related to computer-aided diagnostic and therapy of soft tissues and give a survey of the different types of assistance offered to the urologist: robotization, image fusion, surgical navigation. Both research projects and operational industrial systems are discussed
Jocelyne Troccaz, Michael Baumann 0001, Peter J. Berkelman, Philippe Cinquin, Vincent Daanen, Antoine Leroy, Maud Marchal, Yohan Payan, Emmanuel Promayon, Sandrine Voros, Stéphane Bart, Michel Bolla, Emmanuel Chartier-Kastler, Jean-Luc Descotes, Andrée Dusserre, Jean-Yves Giraud, Jean-Alexandre Long, Ronan Moalic, Pierre Mozer
Proc. IEEE4
2005 Safety and Accuracy Considerations in Developing a Small Sterilizable Robot for Orthopaedic Surgery
abstract
The objective of this work was to design a compact, accurate, safe, and ease-to-use surgical robot for total knee arthroplasty. The goal of the bone-mounted robot, named Praxiteles, is to precisely position a surgical bone-cutting guide in the appropriate planes surrounding the knee, so that the surgeon can perform the cuts manually using the guide. The robot architecture is comprised of 2 motorized degrees of freedom (DOF) whose axes of rotation are arranged in parallel, and are precisely aligned to the implant cutting planes with a 2 DOF serial adjustment mechanism. An initial prototype was first developed and tested on saw bones and cadavers, and construction of a new, refined version is now well underway. A backdrivable system, with high-stiffness, high-precision static positioning capabilities and safe low-force dynamic movement is achieved using a quick-release, spring-loaded mechanical braking system integrated in a gear transmission unit at the level of the motor outputs. This paper discusses the technical challenges encountered during the development, design, and construction of the system.
Christopher Plaskos, Philippe Cinquin, Antony J. Hodgson, Stéphane Lavallée
ICRA2
2004 CT and MR Compatible Light Puncture Robot: Architectural Design and First Experiments
Elise Taillant, Juan-Carlos Avila-Vilchis, Christophe Allegrini, Ivan Bricault, Philippe Cinquin
MICCAI (2)5
2003 LER: the light endoscope robot
abstract
LER is a compact surgical assistant robot for positioning of an endoscope and camera during minimally invasive surgery. In contrast to typical endoscope manipulators, LER is particularly compact and lightweight at 625 g and 110 mm in diameter, so that it is simple to set up and use, occupies no floor space, and does not limit access to the patient in any way. Our current prototype is fully sterilizeable by autoclave and is ready for clinical trials. It features a full motion range of 360/spl deg/ in rotation and inclination to 10/spl deg/ from the horizontal plane and is backdriveable for manual positioning. Actuation forces are limited for safety. LER may be held in place on the abdomen by adhesive strips or sutures, or attached to the sides of the table with elastic straps or clamps. We have implemented a variety of different user command interfaces for LER, including a miniature keypad, automatic optical instrument motion tracking, and voice command recognition. Experimental trajectory following results and performance parameters are given.
Peter J. Berkelman, Eric Boidard, Philippe Cinquin, Jocelyne Troccaz
IROS3
2003 Surgical Robots at TIMC: Where We Are and Where We Go
Jocelyne Troccaz, Philippe Cinquin, Peter J. Berkelman, Adriana Vilchis Gonzales, Eric Boidard
ISRR2
2003 Modelling and Optimization of Bone-Cutting Forces in Orthopaedic Surgery
Christopher Plaskos, Antony J. Hodgson, Philippe Cinquin
MICCAI (1)3
2003 Minimally Invasive Navigation for the Endovascular Treatment of Abdominal Aortic Aneurysm: Preclinical Validation of the Endovax System
Sonia Pujol, Philippe Cinquin, Matthieu Pecher, Ivan Bricault, David Voirin
MICCAI (2)2
2003 A new robot architecture for tele-echography
abstract
This paper presents a slave robot carrying an ultrasound probe for remote echographic examination. This robot is integrated in a master-slave system called robotic tele-echography (TER). The system allows an expert operator to perform a remote diagnosis from echographic data he acquires on a patient located in a distant place. The originality of this robot lies in its architecture: the cable-driven robot is lightweight and semirigid, and it is positioned on the patient body. In this paper, we describe the clinical application, the system architecture, the second implementation of the robot, and experiments performed with this prototype.
Adriana Vilchis Gonzales, Jocelyne Troccaz, Philippe Cinquin, Kohji Masuda, Franck Pellissier
IEEE Trans. Robotics Autom.3
2002 A Compact, Compliant Laparoscopic Endoscope Manipulator
abstract
We have developed a cable-driven manipulator using pneumatic artificial muscle actuators to control the orientation and insertion depth of an endoscope during abdominal surgery. This manipulator enables a single surgeon to manipulate surgical instruments with both hands while the endoscope position is controlled to view an area of interest inside the abdomen. The surgeon may then control the endoscope by alternate methods such as voice commands, pedals, a joystick, or head movements. The advantages of our newly developed endoscope manipulator over those of commercially available robotic laparoscopic surgical systems are its low cost, simplicity, ease of setup and use, compliance, nonintrusiveness, and very small size and light weight, with the disadvantage of somewhat reduced absolute positioning accuracy. Multiple instruments may be manipulated simultaneously by the manipulators set close together. Experimental performance results of open-loop and feedback control methods are presented.
Peter J. Berkelman, Philippe Cinquin, Jocelyne Troccaz, Jean-Marc Ayoubi, Christian Létoublon, F. Bouchard
ICRA2
2002 Development of a Compact Cable-Driven Laparoscopic Endoscope Manipulator
Peter J. Berkelman, Philippe Cinquin, Jocelyne Troccaz, Jean-Marc Ayoubi, Christian Létoublon
MICCAI (1)2
2002 Experiments with the TER Tele-echography Robot
Adriana Vilchis Gonzales, Jocelyne Troccaz, Philippe Cinquin, Agnès Guerraz, Franck Pellissier, Pierre Thorel, Bertrand Tondu, Fabien Courreges, Gérard Poisson, Marc Althuser, Jean-Marc Ayoubi
MICCAI (1)3
2001 TER: A System for Robotic Tele-echography
Adriana Vilchis Gonzales, Philippe Cinquin, Jocelyne Troccaz, Agnès Guerraz, Bernard Hennion, Franck Pellissier, Pierre Thorel, Fabien Courreges, Alain Gourdon, Gérard Poisson, Pierre Vieyres, Pierre Caron, Olivier Mérigeaux, Loïc Urbain, Cédric Daimo, Stéphane Lavallée, Philippe Arbeille, Marc Althuser, Jean-Marc Ayoubi, Bertrand Tondu, Serge Ippolito
MICCAI2
2000 Computer-Assisted Orthognatic Surgery: Consequences of a Clinical Evaluation
Georges Bettega, François Leitner, Olivier Raoult, Vincent Dessenne, Philippe Cinquin, Bernard Raphaël
MICCAI5
1999 Active Model Based Carotid Ultrasonic Data Segmentation
Alexandre Moreau-Gaudry, Philippe Cinquin, Jean-Philippe Baguet
MICCAI2
1998 Multi-Level Strategy for Computer-Assisted Transbronchial Biopsy
Ivan Bricault, Gilbert Ferretti, Philippe Cinquin
MICCAI3
1998 A New Branching Model: Application to Carotid Ultrasonic Data
Alexandre Moreau-Gaudry, Philippe Cinquin, Jean-Philippe Baguet
MICCAI2
1998 Registration of real and CT-derived virtual bronchoscopic images to assist transbronchial biopsy
abstract
This paper describes research work motivated by an innovative medical application: computer-assisted transbronchial biopsy. This project involves the registration, with no external localization device, of a preoperative three-dimensional (3-D) computed tomography (CT) scan of the thoracic cavity (showing a tumor that requires a needle biopsy), and an intraoperative endoscopic two-dimensional (2-D) image sequence, in order to provide assistance in transbronchial puncture of the tumor. Because of the specific difficulties resulting from the data being processed, a multilevel strategy was introduced. For each analysis level, the relevant information to process and the corresponding algorithms were defined. This multilevel strategy, thus, provides the best possible accuracy. Original image processing methods were elaborated, dealing with segmentation, registration and 3-D reconstruction of the bronchoscopic images. In particular, these methods involve adapted mathematical morphology tools, a "daemon-based" registration algorithm, and a model-based shape-from-shading algorithm. This pilot study presents the application of these algorithms to recorded bronchoscopic video sequences for five patients. The preliminary results presented here demonstrate that it is possible to precisely localize the endoscopic camera within the CT data coordinate system. The computer can thus synthesize in near real-time the CT-derived virtual view that corresponds to the actual endoscopic view.
Ivan Bricault, Gilbert Ferretti, Philippe Cinquin
IEEE Trans. Medical Imaging3
1992 Accurate calibration of cameras and range imaging sensor: the NPBS method
abstract
A method is presented for modeling and calibration of sensors, to reach an accuracy similar in magnitude to the resolution of the sensors. The authors focus on camera and range image calibration. They show the limitations of existing methods, and present an approach and camera calibration using mathematical B-Spline functions. This method is abbreviated as NPBS (N-Planes B-Spline). It is an extension of the two-planes method, but relies on pure mathematical modeling based on spline approximation theory. The mathematical modeling is combined with a calibration device that enables accurate data acquisition to calibrate a camera and a light plane independently. Experimental results are presented showing accuracy on the determination of a scattered plane.>
Guillaume Champleboux, Stéphane Lavallée, Pascal Sautot, Philippe Cinquin
ICRA4
1992 Image guided operating robot: a clinical application in stereotactic neurosurgery
abstract
Describes a system based on the combined use of medical imaging and robot positioning used in stereotactic neurosurgery. The types of interventions performed with the help of this system require a high precision (less than 1 millimeter) of positioning with respect to the patients brain with no direct visibility of the target; they are executed through a hole in the skull of 2.3 millimeters. A typical example is the placement of a stimulating electrode in a particular nucleus of the thalamus for patients suffering from Parkinson's disease. These interventions rely on the intensive use of medical imaging to define the operative strategy. The target is defined with respect to the images. A six-axis robot whose end-effector is a linear guide automatically reaches a configuration generated such that if the surgical instrument (needle, electrode, etc.) is introduced in the guide, the surgeon reaches the target using a linear displacement of the instrument. This system is operational and is in routine clinical use.>
Stéphane Lavallée, Jocelyne Troccaz, L. Gaborit, Philippe Cinquin, Alim-Louis Benabid, Dominque Hoffmann
ICRA4