Demo Data from VLDB 2026 / reviewers in the wild / expert
Clare M. Tempany
dblp:73/6901
· DBLP profile ↗
20ranked-venue papers
0as first author
0since 2021 · last 2020
0000-0002-1642-9720ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 14Graphics, computer vision, multimedia, augmented reality and games · 9Artificial intelligence and machine learning · 5Systems, architecture and hardware · 4Human-computer interaction and ubiquitous computing · 1
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
4 papers |
Robot manipulation · 71% Motion planning and robot control · 18% Robot navigation and mapping · 11% | |
| Human-computer interaction and pervasive computing
2 papers |
Interaction techniques and input · 73% User interface design and tools · 22% Health and well-being technologies · 6% | |
| Interdisciplinary, comprehensive, and emerging computing
4 papers |
Medical and health informatics · 100% |
Topics — the 11 heaviest of 16, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Robot manipulation
medical robotics |
0.3 | 3 | 2010 | Development of a pneumatic robot for MRI-guided transperineal prostate biopsy and brachytherapy: New approaches · ICRA 2010 Integrated system for robot-assisted in prostate biopsy in closed MRI scanner · ICRA 2008 Pneumatically operated MRI-compatible needle placement robot for prostate interventions · ICRA 2008 |
Medical and health informatics › image-guided intervention
MRI-guided intervention |
0.2 | 1 | 2013 | Towards clinically optimized MRI-guided surgical manipulator for minimally invasive prostate percutaneous interventions: constructive design · ICRA 2013 |
Robotics › Robot manipulation › actuator design
pneumatic actuation |
0.1 | 2 | 2010 | Development of a pneumatic robot for MRI-guided transperineal prostate biopsy and brachytherapy: New approaches · ICRA 2010 Pneumatically operated MRI-compatible needle placement robot for prostate interventions · ICRA 2008 |
Robotics › Motion planning and robot control › robot control
parallel robot control |
0.1 | 1 | 2010 | Development of a pneumatic robot for MRI-guided transperineal prostate biopsy and brachytherapy: New approaches · ICRA 2010 |
Robotics › Robot manipulation › medical robotics
robotic biopsy |
0.1 | 1 | 2008 | Integrated system for robot-assisted in prostate biopsy in closed MRI scanner · ICRA 2008 |
Medical and health informatics
image-guided intervention |
0.1 | 1 | 2008 | Pneumatically operated MRI-compatible needle placement robot for prostate interventions · ICRA 2008 |
Robotics › Robot manipulation › medical robotics
surgical manipulator |
0.0 | 1 | 2013 | Towards clinically optimized MRI-guided surgical manipulator for minimally invasive prostate percutaneous interventions: constructive design · ICRA 2013 |
Medical and health informatics › medical imaging
medical image analysis |
0.0 | 1 | 2001 | Model-Based Curve Evolution Technique for Image Segmentation · CVPR (1) 2001 |
Medical and health informatics › medical imaging › medical image analysis
medical image segmentation |
0.0 | 1 | 2001 | Model-Based Curve Evolution Technique for Image Segmentation · CVPR (1) 2001 |
Image and video processing
image segmentation |
0.0 | 1 | 2001 | Model-Based Curve Evolution Technique for Image Segmentation · CVPR (1) 2001 |
Robotics › Motion planning and robot control
robot control |
0.0 | 1 | 2008 | Pneumatically operated MRI-compatible needle placement robot for prostate interventions · ICRA 2008 |
Methods — techniques the papers use, named apart from their topics
kinematic optimization · 0.3finite element analysis · 0.3empirical evaluation · 0.3electroluminescence screen printing · 0.3modular system design · 0.2external damping mechanism · 0.2transperineal needle insertion · 0.2pneumatic actuation · 0.2magnetic resonance imaging · 0.2intra-operative MRI · 0.2signed distance representation · 0.1principal component analysis · 0.1implicit curve representation · 0.1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2020 | Confidence Calibration and Predictive Uncertainty Estimation for Deep Medical Image SegmentationabstractFully convolutional neural networks (FCNs), and in particular U-Nets, have achieved state-of-the-art results in semantic segmentation for numerous medical imaging applications. Moreover, batch normalization and Dice loss have been used successfully to stabilize and accelerate training. However, these networks are poorly calibrated i.e. they tend to produce overconfident predictions for both correct and erroneous classifications, making them unreliable and hard to interpret. In this paper, we study predictive uncertainty estimation in FCNs for medical image segmentation. We make the following contributions: 1) We systematically compare cross-entropy loss with Dice loss in terms of segmentation quality and uncertainty estimation of FCNs; 2) We propose model ensembling for confidence calibration of the FCNs trained with batch normalization and Dice loss; 3) We assess the ability of calibrated FCNs to predict segmentation quality of structures and detect out-of-distribution test examples. We conduct extensive experiments across three medical image segmentation applications of the brain, the heart, and the prostate to evaluate our contributions. The results of this study offer considerable insight into the predictive uncertainty estimation and out-of-distribution detection in medical image segmentation and provide practical recipes for confidence calibration. Moreover, we consistently demonstrate that model ensembling improves confidence calibration. Alireza Mehrtash, William M. Wells III, Clare M. Tempany, Purang Abolmaesumi, Tina Kapur |
IEEE Trans. Medical Imaging | 3 |
| 2019 | Automatic Needle Segmentation and Localization in MRI With 3-D Convolutional Neural Networks: Application to MRI-Targeted Prostate BiopsyabstractImage guidance improves tissue sampling during biopsy by allowing the physician to visualize the tip and trajectory of the biopsy needle relative to the target in MRI, CT, ultrasound, or other relevant imagery. This paper reports a system for fast automatic needle tip and trajectory localization and visualization in MRI that has been developed and tested in the context of an active clinical research program in prostate biopsy. To the best of our knowledge, this is the first reported system for this clinical application and also the first reported system that leverages deep neural networks for segmentation and localization of needles in MRI across biomedical applications. Needle tip and trajectory were annotated on 583 T2-weighted intra-procedural MRI scans acquired after needle insertion for 71 patients who underwent transperineal MRI-targeted biopsy procedure at our institution. The images were divided into two independent training-validation and test sets at the patient level. A deep 3-D fully convolutional neural network model was developed, trained, and deployed on these samples. The accuracy of the proposed method, as tested on previously unseen data, was 2.80-mm average in needle tip detection and 0.98° in needle trajectory angle. An observer study was designed in which independent annotations by a second observer, blinded to the original observer, were compared with the output of the proposed method. The resultant error was comparable to the measured inter-observer concordance, reinforcing the clinical acceptability of the proposed method. The proposed system has the potential for deployment in clinical routine. Alireza Mehrtash, Mohsen Ghafoorian, Guillaume Pernelle, Alireza Ziaei, Friso G. Heslinga, Kemal Tuncali, Andriy Fedorov, Ron Kikinis, Clare M. Tempany, William M. Wells III, Purang Abolmaesumi, Tina Kapur |
IEEE Trans. Medical Imaging | 9 |
| 2018 | Insert Needle Here! A Custom Display for Optimized Biopsy Needle PlacementabstractNeedle-guiding templates are used for a variety of minimally invasive medical interventions. While physically supporting needle placement with a grid of holes, they lack integrated information where needles need to be inserted. Physicians must manually determine the correct holes based on the output of planning software - a workflow that is error-prone and lengthy. We address these issues by embedding a display into the template using electroluminescence (EL) screen printing. The EL display is connected to planning software and illuminates the correct hole. In an empirical evaluation with physicians and researchers from the medical domain, we compare the illuminated against the conventional template as used in magnetic resonance imaging (MRI) guided prostate biopsies. Our results show that the EL display significantly improves task completion time by 51%, task load by 47% and usability by 30%. Anke V. Reinschlüssel, Marc Herrlich, Tanja Döring, Mark G. Vangel, Clare M. Tempany, Rainer Malaka, Junichi Tokuda |
CHI | 5 |
| 2017 | Transfer Learning for Domain Adaptation in MRI: Application in Brain Lesion Segmentation
Mohsen Ghafoorian, Alireza Mehrtash, Tina Kapur, Nico Karssemeijer, Elena Marchiori, Mehran Pesteie, Charles R. G. Guttmann, Frank-Erik de Leeuw, Clare M. Tempany, Bram van Ginneken, Andriy Fedorov, Purang Abolmaesumi, Bram Platel, William M. Wells III |
MICCAI (3) | 9 |
| 2014 | Application of Tolerance Limits to the Characterization of Image Registration PerformanceabstractDeformable image registration is used increasingly in image-guided interventions and other applications. However, validation and characterization of registration performance remain areas that require further study. We propose an analysis methodology for deriving tolerance limits on the initial conditions for deformable registration that reliably lead to a successful registration. This approach results in a concise summary of the probability of registration failure, while accounting for the variability in the test data. The (β, γ) tolerance limit can be interpreted as a value of the input parameter that leads to successful registration outcome in at least 100β% of cases with the 100γ% confidence. The utility of the methodology is illustrated by summarizing the performance of a deformable registration algorithm evaluated in three different experimental setups of increasing complexity. Our examples are based on clinical data collected during MRI-guided prostate biopsy registered using publicly available deformable registration tool. The results indicate that the proposed methodology can be used to generate concise graphical summaries of the experiments, as well as a probabilistic estimate of the registration outcome for a future sample. Its use may facilitate improved objective assessment, comparison and retrospective stress-testing of deformable. Andriy Fedorov, William M. Wells III, Ron Kikinis, Clare M. Tempany, Mark G. Vangel |
IEEE Trans. Medical Imaging | 4 |
| 2013 | Towards clinically optimized MRI-guided surgical manipulator for minimally invasive prostate percutaneous interventions: constructive designabstractThis paper undertakes the modular design and development of a minimally invasive surgical manipulator for MRI-guided transperineal prostate interventions. Severe constraints for the MRI-compatibility to hold the minimum artifact on the image quality and dimensions restraint of the bore scanner shadow the design procedure. Regarding the constructive design, the manipulator kinematics has been optimized and the effective analytical needle workspace is developed and followed by proposing the workflow for the manual needle insertion. A study of the finite element analysis is established and utilized to improve the mechanism weaknesses under some inevitable external forces to ensure the minimum structure deformation. The procedure for attaching a sterile plastic drape on the robot manipulator is discussed. The introduced robotic manipulator herein is aimed for the clinically prostate biopsy and brachytherapy applications. Sohrab Eslami, Gregory S. Fischer, Sang-Eun Song, Junichi Tokuda, Nobuhiko Hata, Clare M. Tempany, Iulian Iordachita |
ICRA | 6 |
| 2013 | Configurable Automatic Detection and Registration of Fiducial Frames for Device-to-Image Registration in MRI-Guided Prostate Interventions
Junichi Tokuda, Sang-Eun Song, Kemal Tuncali, Clare M. Tempany, Nobuhiko Hata |
MICCAI (3) | 4 |
| 2012 | Selection of Optimal Hyper-Parameters for Estimation of Uncertainty in MRI-TRUS Registration of the Prostate
Petter Risholm, Firdaus Janoos, Jennifer Pursley, Andriy Fedorov, Clare M. Tempany, Robert A. Cormack, William M. Wells III |
MICCAI (3) | 5 |
| 2010 | Development of a pneumatic robot for MRI-guided transperineal prostate biopsy and brachytherapy: New approachesabstractMagnetic Resonance Imaging (MRI) guided prostate biopsy and brachytherapy has been introduced in order to enhance the cancer detection and treatment. For the accurate needle positioning, a number of robotic assistants have been developed. However, problems exist due to the strong magnetic field and limited workspace. Pneumatically actuated robots have shown the minimum distraction in the environment but the confined workspace limits optimal robot design and thus controllability is often poor. To overcome the problem, a simple external damping mechanism using timing belts was sought and a 1-DOF mechanism test result indicated sufficient positioning accuracy. Based on the damping mechanism and modular system design approach, a new workspace-optimized 4-DOF parallel robot was developed for the MRI-guided prostate biopsy and brachytherapy. A preliminary evaluation of the robot was conducted using previously developed pneumatic controller and satisfying results were obtained. Sang-Eun Song, Nathan Bongjoon Cho, Gregory S. Fischer, Nobuhiko Hata, Clare M. Tempany, Gabor Fichtinger, Iulian Iordachita |
ICRA | 5 |
| 2008 | Pneumatically operated MRI-compatible needle placement robot for prostate interventionsabstractMagnetic Resonance Imaging (MRI) has potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. The strong magnetic field prevents the use of conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intra-prostatic needle placement inside closed high-field MRI scanners. The robot performs needle insertion under real-time 3T MR image guidance; workspace requirements, MR compatibility, and workflow have been evaluated on phantoms. The paper explains the robot mechanism and controller design and presents results of preliminary evaluation of the system. Gregory S. Fischer, Iulian Iordachita, Csaba Csoma, Junichi Tokuda, Philip Walter Mewes, Clare M. Tempany, Nobuhiko Hata, Gabor Fichtinger |
ICRA | 6 |
| 2008 | Integrated system for robot-assisted in prostate biopsy in closed MRI scannerabstractProstate cancer biopsy is a routine medical procedure, yet conventional techniques suffer from low sensitivity attributed to suboptimal image guidance and needle placement. Targeting small lesions and foci (5 mm in diameter) is particularly prone to errors. We developed an integrated system to perform robot-assisted transperineal needle insertions into the prostate, under Magnetic Resonance Imaging (MRI) guidance. The system provides arbitrary needle trajectories and allows for simultaneous surveillance and correction of the needle path, based on intra-operative MRI. System functionality and data transfer and processing tests were conducted. Five lesions embedded in the gel phantom were targeted successfully, while communication delays (due to higher image frame rates) had no adverse affect on robot-software communication. The system was sufficiently resistant to high network loads and performed with an acceptable transfer rate. Philip Walter Mewes, Junichi Tokuda, Simon P. DiMaio, Gregory S. Fischer, Csaba Csoma, David G. Gobbi, Clare M. Tempany, Gabor Fichtinger, Nobuhiko Hata |
ICRA | 7 |
| 2008 | Software Strategy for Robotic Transperineal Prostate Therapy in Closed-Bore MRI
Junichi Tokuda, Gregory S. Fischer, Csaba Csoma, Simon P. DiMaio, David G. Gobbi, Gabor Fichtinger, Clare M. Tempany, Nobuhiko Hata |
MICCAI (2) | 7 |
| 2007 | Dynamic MRI Scan Plane Control for Passive Tracking of Instruments and Devices
Simon P. DiMaio, Eigil Samset, Gregory S. Fischer, Iulian Iordachita, Gabor Fichtinger, Ferenc A. Jolesz, Clare M. Tempany |
MICCAI (2) | 7 |
| 2007 | Application of Open Source Image Guided Therapy Software in MR-guided Therapies
Nobuhiko Hata, Steven D. Pieper, Ferenc A. Jolesz, Clare M. Tempany, Peter M. Black, Shigehiro Morikawa, Hiroshi Iseki, Makoto Hashizume, Ron Kikinis |
MICCAI (1) | 4 |
| 2005 | Capturing intraoperative deformations: research experience at Brigham and Women's hospital
Simon K. Warfield, Steven Haker, Ion-Florin Talos, Corey Kemper, Neil I. Weisenfeld, Andrea J. U. Mewes, Daniel Goldberg-Zimring, Kelly H. Zou, Carl-Fredrik Westin, William M. Wells III, Clare M. Tempany, Alexandra J. Golby, Peter M. Black, Ferenc A. Jolesz, Ron Kikinis |
Medical Image Anal. | 11 |
| 2004 | Landmark-Guided Surface Matching and Volumetric Warping for Improved Prostate Biopsy Targeting and Guidance
Steven Haker, Simon K. Warfield, Clare M. Tempany |
MICCAI (1) | 3 |
| 2004 | Improved Non-rigid Registration of Prostate MRI
Aloys du Bois d'Aische, Mathieu De Craene, Steven Haker, Neil I. Weisenfeld, Clare M. Tempany, Benoît Macq, Simon K. Warfield |
MICCAI (1) | 5 |
| 2004 | Mutual information in coupled multi-shape model for medical image segmentation
Andy Tsai, William M. Wells III, Clare M. Tempany, W. Eric L. Grimson, Alan S. Willsky |
Medical Image Anal. | 3 |
| 2003 | A Shape-Based Approach to the Segmentation of Medical Imagery Using Level SetsabstractWe propose a shape-based approach to curve evolution for the segmentation of medical images containing known object types. In particular, motivated by the work of Leventon, Grimson, and Faugeras, we derive a parametric model for an implicit representation of the segmenting curve by applying principal component analysis to a collection of signed distance representations of the training data. The parameters of this representation are then manipulated to minimize an objective function for segmentation. The resulting algorithm is able to handle multidimensional data, can deal with topological changes of the curve, is robust to noise and initial contour placements, and is computationally efficient. At the same time, it avoids the need for point correspondences during the training phase of the algorithm. We demonstrate this technique by applying it to two medical applications; two-dimensional segmentation of cardiac magnetic resonance imaging (MRI) and three-dimensional segmentation of prostate MRI. Andy Tsai, Anthony J. Yezzi, William M. Wells III, Clare M. Tempany, Dewey Tucker, Ayres C. Fan, W. Eric L. Grimson, Alan S. Willsky |
IEEE Trans. Medical Imaging | 4 |
| 2001 | Model-Based Curve Evolution Technique for Image SegmentationabstractWe propose a model-based curve evolution technique for segmentation of images containing known object types. In particular, motivated by the work of Leventon et al. (2000), we derive a parametric model for an implicit representation of the segmenting curve by applying principal component analysis to a collection of signed distance representations of the training data, The parameters of this representation are then calculated to minimize an objective function for segmentation. We found the resulting algorithm to be computationally efficient, able to handle multidimensional data, robust to noise and initial contour placements, while at the same time, avoiding the need for point correspondences during the training phase of the algorithm. We demonstrate this technique by applying it to two medical applications. Andy Tsai, Anthony J. Yezzi, William M. Wells III, Clare M. Tempany, Dewey Tucker, Ayres C. Fan, W. Eric L. Grimson, Alan S. Willsky |
CVPR (1) | 4 |