Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Holger Hewener

dblp:88/4044 · DBLP profile ↗
← Back
1ranked-venue papers
0as first author
0since 2021 · last 2019
0000-0003-2191-6053ORCID · reported

Domains — the database's venue-derived domains; a paper can count in several

Human-computer interaction and ubiquitous computing · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Human-computer interaction and pervasive computing
1 paper
Wearable and physiological sensing · 77% Health and well-being technologies · 23%

Topics — the 2 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Wearable and physiological sensing › acoustic sensing
ultrasonic sensing
0.412019
Towards a wearable low-cost ultrasound device for classification of muscle activity and muscle fatigue · UbiComp 2019
Health and well-being technologies
rehabilitation
0.112019
Towards a wearable low-cost ultrasound device for classification of muscle activity and muscle fatigue · UbiComp 2019

Methods — techniques the papers use, named apart from their topics

sequence similarity measurement · 0.4machine learning · 0.4artificial neural network · 0.4
YearPublicationVenuePosition
2019 Towards a wearable low-cost ultrasound device for classification of muscle activity and muscle fatigue
abstract
Being able to reliably predict muscle contractions is important for athletes and rehabilitation patients alike. Numerous techniques and surrogates exist for this task. However, they are in general not well suited for everyday use and not able to extract information of muscles located in deeper body layers. To address this shortcoming, we present an approach to classify muscle contractions with raw ultrasound radio-frequency data (A-Scans) collected with a wearable system. It consists of a single element ultrasound transducer connected to custom-built acquisition hardware and an Android app to receive, store and analyze the data. We rely on data from the lower legs of healthy volunteers performing squats as sample exercises and use machine learning methods, ranging from sequence similarity measurement techniques to artificial neural networks, to classify the radio-frequency data. Results of our preliminary experimental setup prove its feasibility to classify muscle contractions based on ultrasound measurements.
Lukas Brausch, Holger Hewener, Paul Lukowicz
UbiComp2